0.3t MRI Magnetic Resonance Imaging Equipment Self Shielding Permanent Whole Body

Price $236000.00 Compare
Min Order 1 Set
Shipping From Jiangsu, China
Popularity 363 people viewed
Quantity
+-
 

Yangzhou Kindsway Biotech Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
0.3T
Imaging Diagnostic Equipment
Digital Imaging System
CE, ISO13485
All
Kindsway
40gp
0.3T
China
9018130000
Product Description

Oermanent MRI,Open Mri,Whole Body MRI for Medical Imaging 

0.30T Permanent Magnet MRI Scanner
 
Related introduction
  • Eddy zero technology

Make sure the imaging quality achieved qualitative improve.

 

The shimming algorithm technology (ensure field strength with high uniformity and stability), ensure the MRI system operating stably with high quality and high performance.

 

The high magnetic uniformity, high stability, fast and accurate position operation are always the hard breakthrough technical bottleneck. BTI-030 permanent MRI system not only breakthrough the bottleneck historically, and achieved the "high stability, high performance, high imaging quality and high efficiency". And with the special designed high power gradient magnet field for BTI-030, it achieved as an all-new concept permanent MRI system.

 

  • Much open and comfort

More patient comfort and more space for surgery. Affinity C-shape magnets, creating a maximum of openness, offer a maximum vision for patients, especially leave much space comfort for obese patients, minimizing claustrophobia of patients and providing more space for MR intervention surgery.

 

  • Very good gradient system

Gradient system helps to provide higher resolution pictures, BTI-030 gradient system(X,Y,Z) gradient intensity is 25mT/m,Higher the gradient intensity, faster imaging speed, shorter of scanning time; Higher the gradient intensity, thinner of imaging slice, higher of image resolution

 

  • The new technology

4D shimming:

Use of advanced active shimming algorithm for real-time automatic shimming on each examination to ensure the magnetic field always maintain the highest uniformity. Magnetic field homogeneity and stability of the MRI images always are the most important guarantee of the high-resolution, high SNR and high contrast. They are the important indicators of the level of magnet design, the better the smaller the value, directly determines the SNR of the image, like a car chassis, stability is essential, the magnetic field uniformity is maintained at <2.5ppm in 40cm the DSV Vrms, the system can complete a wide range of scanning (40cm).

 

  • Eddy Zero Technology:
  1. Magnet design uses breakthrough anti-eddy current technology
  2. The gradient coil using self-shielded active anti - eddy current technology
  3.  Implementation of precision eddy current compensation algorithm, completely eliminate the impact of eddy current

    The eddy current because of the high gradient and high slew rate come from ultra-fast sequence was resolved completely, which guarantee to get the best clinic image.

  • Advanced RF system

Fast 4 channels RF system

All phased array coils provide best SNR pictures.

 

 

Standard ConfigurationsUnitQuantity
Standard Hardware include:  
RF shielding roomset1
Permanent Nd-Fe-B magnet, Full open C-shaped eddy current-free self-consistent temperature magnet 0.35Tset1
Spectrometerpc1
Preamplifierset1
RF amplifierpc1
Flat panel transmitter coilset1
Gradient amplifierpc1
Gradient coilset1
Computerset1
Imaging monitorset1
Operation tableset1
Cover and diagnostic bedset1
Head coilset1
Neck coilset1
Small body coilset1
Large body coilset1
Knee coilset1
bed patsset1
Quality control water phantompc1
MRI safety marksset1
Technical manualpc1
User manualpc1
Maintenance manualpc1
3-phase AC voltage stabilizerpc1
Magnet self-consistent temperature systemset1
Dual-voice-communication systemset1
Patient bed laser location systemset1
   
Standard Software include  
Imaging softwareset1
Pulse sequenceset1
Imaging enhancement softwareset1
DICOM interface softwareset1
Cardiovascular imaging softwareset1
Diffusion functional imaging system packageset1
(MR CINE)/ MR CINEset1
Accident analyzing softwareset1
Quality control software  
   
Optional ModulesUnit 
Shoulder coilset 
Sport joint coilset 
Wrist Coilset 
Breast Coilset 
Flexible coilset 
Flexible body coilset 
Flat spine coilset 
Remark: RF shielding room are including RF shielding room decoration, RF shielding door, observation window, transmission board, Waveguide plate, interior lighting; excluding room construction and flooring, outside decoration of RF shielding room, operation room, equipment room, air-conditioner room and air-conditioner, external electric access and independent ground lead.  
Basda will provide the technical staff for installation, including RF shielding room installation, MRI system installation, and training; The buyer shall bear round trip air ticket from China to installation country, local transportation, food and board of Basda's technicians in country of installation for the purpose of installation, training and service.  
Contents are subject to change without prior notice  

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA