0.75kw/1HP 1.5kw/2HP 220V Single Phase Input Output Three Phase 220V VFD

Price $40.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 233 people viewed
Quantity
+-
 

Jiangsu Robin Kang Automation Technology Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
K10-2S01R5G
High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Triple
Vector Control Transducer
PWM Control
Current
Low Voltage Variable-Frequency Drive
AC-DC-AC Variable-Frequency Drive
Current Variable-Frequency Drive
Simple Type, Textile Special
Rbca
0.75-2.2kw
-10 -- 50
1000Hz
Build-in
RBCA
Carton
China
85044090
Product Description
Product Description
 

 

InputRated voltage, frequencyThree-phase (4T series ) 380V;50/60HZ  Single phase (2 S series) 220V: 50/60HZ 
Allowable voltage variation rangeThree-phase (4T series ) 320V ~ 460V    Single phase (2 S series) 190V~250V
OutputVoltage4T series; 0~380V 2 S series; 0~220V
FrequencyV/ F control, simple vector control : 0.0 ~ 999.9HZ
Advanced vector control , torque control : 0.5 ~ 300.0 HZ
Overload capacity110% long term 150% 1 minute 180% 5 seconds
Control methodV/F control, simple vector control, advanced vector control, torque control
Control characteristicsFrequency setting resolutionAnalog input0.1% of maximum output frequency
Digital settings0.1HZ
Frequency accuracyAnalog inputWithin 0.2% of the maximum output frequency
digital inputWithin 0.01% of the set output frequency
V/F controlV/F curve (voltage frequency characteristics)Three methods: the first is the linear torque characteristic curve, the second is the square torque characteristic curve, and the third is the user-set V/F curve.
Torque boostManual setting: 0.0~30.0% of rated output
Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters
Automatic current limiting and pressure limitingWhether during acceleration, deceleration or stable operation, the motor stator current and voltage are automatically detected and suppressed within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping.
Inductive vector controlVoltage frequency characteristicsAutomatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm
Torque characteristicsStarting torque:
100% rated torque at 5.0Hz (VF control)
150% rated torque at 1.0Hz (vector control)
Current and voltage suppressionFull current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression functions
Undervoltage suppression during operationEspecially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy.
Typical functionsMulti-speed operation7-segment programmable multi-segment speed control, multiple operating modes available.
PID control
RS485 communication
Built-in PID controller (frequency can be preset). Standard configuration RS485 communication function, multiple communication protocols optional, with linkage synchronous control function
Frequency settingAnalog inputDC voltage 0~10V, DC current 0~20mA (upper and lower limits optional)
Digital inputOperation panel setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input
output signalRelay output1 relay output (TA, TC), up to 17 meaning options
Analog output1 analog signal output, the output range can be flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency.
Automatic voltage stabilization operationYou can choose dynamic voltage stabilization, static voltage stabilization, or unstabilized voltage according to your needs to obtain the most stable operating effect.
Acceleration and deceleration time setting0.1S~999.9min continuously configurable
BrakeEnergy consumption brakingEnergy consumption braking starting voltage, hysteresis voltage and energy consumption braking rate are continuously adjustable
DC brakingStop DC braking starting frequency: 0.00~[F0.05] upper limit frequency
Braking time: 0.0~30.0s; Braking current: 0.0%~50.0% of motor rated voltage
Low noise operationThe carrier frequency is continuously adjustable from 2.0KHZ to 20.0KHZ to minimize motor noise.
counterAn internal counter to facilitate system integration
run functionUpper and lower limit frequency settings, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.
 
DisplayOperation panel displayOperating statusOutput frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc.
Alarm contentRecords of output frequency, set frequency, output current, output voltage, DC voltage, module temperature and other operating parameters during the latest fault
Protective functionOvercurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc.
EnvironmentAmbient temperature-10ºC~+40ºC (environment temperature is between 40ºC~50ºC, please derate for use)
Ambient humidity5%~95%RH, no water droplets condensation
SurroundingsIndoor (no direct sunlight, no corrosion, flammable gas, oil mist, dust, etc.)
AltitudeDerating for use above 1000 meters, derate by 10% for every 1000 meters.
StructureProtection levelIP20
Cooling methodAir-cooled, with fan control
Installation methodWall-mounted
Selection guide

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA