1/C Cu 15kv 175 Trxlpe 100% PVC Mv-105 Mv Power Cable

Price $18.00 Compare
Min Order 500 Meters
Shipping From Jiangsu, China
Popularity 449 people viewed
Quantity
+-
 

Jiangsu Jinling Cable Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
MV-105
Underground, Power Station
Low and Medium Voltage Cable
DC & AC
XLPE
PE/PVC
Round Wire
Bare Copper Wire
CCC, CE
Mv-105
Jl
15kv
1
IEC 60502-2,BS6022
JL
Wooden Drum/Steel Drum
1.5-500Mm2
Jiangsu, China
8544492100
Product Description

Standards

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4-ST1 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV

Application
15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. 

 Construction

Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Conductor Shield:Semi-conducting cross-linked copolymer
Insulation:175 Mils Tree Retardent Cross Linked Polyethylene (TRXLPE) 100% Insulation Level,
Insulation Shield:Stripable semi-conducting cross-linked copolymer
Copper Tape Shield:Helically wrapped 5 mil copper tape with 25% overlap
Overall Jacket:Polyvinyl Chloride (PVC)

 

 Parameter:

Cond. SizeDiameter Over ConductorDiameter Over InsulationDiameter Over Insulation ShieldJacket ThicknessApprox. ODApprox. WeightMax Pull TensionMin Bending Radius
AWG/Kcmilinchesinchesinchesmilsincheslbs./MFTlbs.inches
20.2830.670.73650.8851453110.6
10.3220.7090.769800.94961067011.4
'1/00.3620.7490.809800.98969984511.9
'2/00.4050.7920.852801.032807106512.4
'3/00.4560.8430.903801.083942134213
'4/00.5120.8990.959801.1391107169313.7
2500.5580.9541.014801.1941254200014.3
3500.6611.0571.117801.2971619280015.6
5000.7891.1851.245801.4252151400017.1
7500.9681.3731.433801.6133024600019.4
10001.1171.5221.5821101.8223974800021.9