APPLICATION:
* data-center critical network devices
* sensitive electronic equipment, telecom
* bank,hospital, bureau, traffic, public security,ATM and so on
FEATURES:
♦ Online double conversion technology With advanced DSP control.
♦ Wide input voltage range(110 ~ 300VAC),can adapt to different power grid environment.
♦ DC start function, Input PFC revises function, input power factor above 0.98.
♦ Output power factor0.9, strong load capacity.
♦ Supporting rack/tower structure, high power density saving space.
♦ Excellent Pretention against over voltage, overload, Over current, overcharge and so on.
♦ LCD display and LED indicator show detailed UPS status and parameters.
• Friendly man-machine interface, Simple setting Output Voltage, Frequency parameter and Bypass function on the display.
• Smart RS232 communication with monitoring software.
• Smart slot can provide abundant extensible function; can choose to install Win-power, SNMPcard.
• Lightning, surge, short -circuit, network/fax/mo dem surge protection.
SPECIFICATIONS:
Model | RT1K | RT1KL | RT2K | RT2KL | RT3K | RT3KL | RT6K | RT6KL | RT10K | RT10KL | ||
Capacity | VA/W | 1000VA/800W | 1000VA/800W | 2000VA/1600W | 2000VA/1600W | 3000VA/2400W | 3000VA/2400W | 6000VA/4800W | 6000VA/4800W | 10000VA/8000W | 10000VA/8000W | |
Input | Nominal Voltage | 200/208/220/230/240VAC | ||||||||||
Voltage Range | 115~300VAC | 120~275VAC | ||||||||||
Power Factor | ≥0.98 | ≥0.99 | ||||||||||
Frequency Range | 50Hz:46~54Hz; 60Hz:56~64Hz | |||||||||||
Output | Voltage | 200/208/220/230/240(1±1%)VAC | 200/208/220/230/240(1±1%)VAC | |||||||||
Frequency | 50/60Hz (Adjustable); 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%) | |||||||||||
Wave Form | Pure sine wave | |||||||||||
Power Factor | 0.9 | |||||||||||
Harmonic Distortion | ≤4% THD (Linear load) ≤7% THD (Non-Linear load) | ≤2% THD (Linear load) ≤4% THD (Non-Linear load) | ||||||||||
Overload Capacity | 105%~150% maintain 25s-45s then turn to bypass ourput 150%~200% maintain 300ms-25s then turn to bypass ourput ≥200% maintain 200ms then turn to bypass ourput | Load <105% work consistant; 105%<load <125% 1min; 125%<load <150% 30sec | ||||||||||
Current Crest Ratio | 3:01 | |||||||||||
Connections | IEC320-10A*6 | IEC320-10A*8 | IEC320-10A*8 | Terminal block | ||||||||
Efficiency | Battery Mode | 89% | 87% | |||||||||
AC Mode | 94% | 88% | ||||||||||
Battery | Type | Sealed free maintenance lead acid battery | ||||||||||
Nominal DC voltage | 24VDC | 24VDC | 48VDC | 48VDC | 72VDC | 72VDC | 192VDC | 192VDC | 192VDC | 192VDC | ||
Battery Numbers&Capacity | 2*12V 9AH | Long backup | 4*12V 9AH | Long backup | 6*12V 9AH | Long backup | 16*12V 9AH | Long back up | 16*12V 9AH | Long back up | ||
Backup Time (Full Load) | ≥2.5min | Depens on capacity of external battery bank | ≥3min | Depens on capacity of external battery bank | ≥3min | Depens on capacity of external battery bank | ≥5min | Depens on capacity of external battery bank | ≥4min | Depens on capacity of external battery bank | ||
Charge Current (Max) | 1.0A | 2.0A | 1.0A | 2.0A | 1.0A | 2.0A | 1.0A | 4.5A | 1.0A | 4.5A | ||
Charge Voltage (VDC) | 27.4V±0.2VDC | 27.4V±0.2VDC | 54.8V±0.4VDC | 54.8V±0.4VDC | 82.2V±0.6VDC | 82.2V±0.6VDC | 218.4V±2VDC | 218.4V±2VDC | 218.4V±2VDC | 218.4V±2VDC | ||
Recharge Time | 5hours to 90% | Depends on the capacity of internal battery bank | 5hours to 90% | Depends on the capacity of internal battery bank | 5hours to 90% | Depends on the capacity of internal battery bank | 7hours to 90% | Depends on the capacity of internal battery bank | 7hours to 90% | Depends on the capacity of internal battery bank | ||
Bypass | Automatic Transfer | On overload and UPS failure | ||||||||||
Before UPS Power-on | YES | |||||||||||
Transfer Time | 0 ms(from imain to battery and vice versa); Less than 4ms from inverter to bypass and vice versa | |||||||||||
indicators | LCD Display | UPS status, Battery capacity, loading, Fault code (LCD: I/P&O/P voltage&frequency, Battery voltage) | ||||||||||
Audible | Bypass, Battery mode, Battery low, Overload, Fault | |||||||||||
Communications | Intelligent RS232 serial port | Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC | ||||||||||
SNMP (Optional) | Remote control UPS through SNMP management and Internet | |||||||||||
USB (Optional) | Windows family software and Mac OS | |||||||||||
Environmental | Operating Temperature | 0~40ºC | ||||||||||
Operating Humidity | 20~90% (No condensing) |
COMPANY SHOW:


Q 1. What's the payment terms and payment method ?
A. We accept L/C, T/T, Credit Card, Western Union, Money Gram, etc.
Usually 30% deposit, 70% before shipment.
Q 2. How's the delivery time ?
A. It usually takes about 3-10 days after payment arrived.
Q 3. How about package ?
A. For the small UPS and the inverters less than 30kg will be packed in foams and cartons. For the big UPS and inverters heavier than 30kg will be packed in pallets or wood boxes .
Q 4. Would you accept to print our logo and design ?
A. Yes, we can print your logo on the inverters, UPS and cartons. Also welcomed your own design of these inverters and UPS.
Q 5. What kind of certificates you have ?
A. For company have ISO9001, ISO14001, TUV and SGS factory certification.
For UPS and power inverters, we have CE,IEC, KC and ETL, etc.
Q6. When the product have problem, how to solve it ?