1000mg/6ml Florisil Spe Column for Gc LC Sample Preparation in Environmental Analysis

Price $1.17 Compare
Min Order 30 Pieces
Shipping From Fujian, China
Popularity 219 people viewed
Quantity
+-
 

Raykol Group (XiaMen) Corp., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
RC-204-16945
The Standard-Compliant Recovery Rate
36 Months
Disposable
Solid
Rubber / Plastic
OEM, ODM
7days
Ex-Work
Florisil
Special Spe Cartridge
RayCure
30/Pack
1000mg/6mL
China
84219990
Product Description
RayCure Florisil cartridge utilizes natural Florisil as adsor- bent. With strong adsorption, it's used to retain highly polar compounds from non-polar solutions, suitable for purification of pesticide residues in crops. It is mainly used to separate and purify pesticide residues.


 
Product Specifications
Part numberDescription
RC-204-13802SPE cartridge:RayCure GCB,250mg/6mL,30/Pack
RC-204-13804SPE cartridge:RayCure GCB,500mg/6mL,30/Pack
RC-204-13806SPE cartridge:RayCure GCB,250mg/3mL,50/Pack
RC-204-13807SPE cartridge:RayCure GCB,2000mg/12mL,20/Pack
RC-204-68305SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack
RC-204-16861SPE cartridge:RayCure AL-A,100mg/1mL,100/Pack
RC-204-16862SPE cartridge:RayCure AL-A,200mg/3mL,50/Pack
RC-204-16863SPE cartridge:RayCure AL-A,500mg/3mL,50/Pack
RC-204-16864SPE cartridge:RayCure AL-A,500mg/6mL,30/Pack
RC-204-16865SPE cartridge:RayCure AL-A,1000mg/6mL,30/Pack
RC-204-16866SPE cartridge:RayCure AL-A,2000mg/6mL,30/Pack
RC-204-16867SPE cartridge:RayCure AL-A,60mg/3mL,50/Pack
RC-204-16881SPE cartridge:RayCure AL-B,100mg/1mL,100/Pack
RC-204-16882SPE cartridge:RayCure AL-B,200mg/3mL,50/Pack
RC-204-16883SPE cartridge:RayCure AL-B,500mg/3mL,50/Pack
RC-204-16884SPE cartridge:RayCure AL-B,500mg/6mL,30/Pack
RC-204-16885SPE cartridge:RayCure AL-B,1000mg/6mL,30/Pack
RC-204-16886SPE cartridge:RayCure AL-B,2000mg/6mL,30/Pack
RC-204-16887SPE cartridge:RayCure AL-B,2000mg/12mL,20/Pack
RC-204-16901SPE cartridge:RayCure AL-N,100mg/1mL,100/Pack
RC-204-16902SPE cartridge:RayCure AL-N,200mg/3mL,50/Pack
RC-204-16903SPE cartridge:RayCure AL-N,500mg/3mL,50/Pack
RC-204-16904SPE cartridge:RayCure AL-N,500mg/6mL,30/Pack
RC-204-16904NSPE cartridge: RayCure AL-N,500mg/6mL,30/Pack,SPE-06D specific
RC-204-16905SPE cartridge:RayCure AL-N,1000mg/6mL,30/Pack
RC-204-16906SPE cartridge:RayCure AL-N,2000mg/6mL,30/Pack
RC-204-16907SPE cartridge:RayCure AL-N,60mg/3ml,50/Pack
RC-204-16908SPE cartridge:RayCure AL-N,1000mg/3mL,50/Pack
RC-204-16909SPE cartridge:RayCure AL-N,20g/60ml,10/Pack
RC-204-16941SPE cartridge:RayCure Florisil ,100mg/1mL,100/Pack
RC-204-16942SPE cartridge:RayCure Florisil ,200mg/3mL,50/Pack
RC-204-16943SPE cartridge:RayCure Florisil ,500mg/3mL,50/Pack
RC-204-16944SPE cartridge:RayCure Florisil ,500mg/6mL,30/Pack
RC-204-16945SPE cartridge:RayCure Florisil ,1g/6mL,60-100Mesh,30/Pack
RC-204-16947SPE cartridge:RayCure Florisil ,500mg/12mL,20/Pack
RC-204-16948SPE cartridge:RayCure Florisil ,1g/12mL,20/Pack
RC-204-16949SPE cartridge:RayCure Florisil ,1g/6mL,100-200Mesh,30/Pack
RC-204-68305SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack
RC-204-E4301SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack
RC-204-E4301NSPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack,SPE-06D specific
RC-204-E4302SPE cartridge:RayCure Na2SO4,1g/6mL,30/Pack
 

HOW DOES SPE COLUMN WORK?

SPE is a conventional and efficient extraction technique, it uses the affinity of solutes dissolved or suspended in mobile phase for stationary phase to separate desired compounds from a mixture. And there are two solid phase extraction mechanisms to obtain target analytes from complex samples, to retain desired compounds in stationary phase or retain impurities in solid phase. Depending on the difference of two mechanisms, SPE procedures could be a bit various. 

 

When sample portion passes through SPE column, undesired impurities are discarded with mobile phase, target compounds are retained in stationary phase, then rinse stationary phase with eluents to collect target compounds. It is the most commonly used purification mechanism of solid phase extraction. 

 

In the opposite, to retain impurities in stationary phase, target compounds and few impurities are collected in mobile phase when sample portion passes through SPE column. Rinse the stationary phase which impurities is retained with solvents to obtain rest of retained target compounds. This mechanism is mostly used to eliminate fat-soluble impurities of ion analysis and analysis of multiple pesticides in fruits and vegetables.

 

Company Profile



Raykol Group is a leading professional supplier focusing on R&D, design and manufacture for automated laboratory equipment and solutions in the laboratory automation systems market. And we provide pre-sales product selection guide and after-sales technical supports. RayKol's automted lab systems and products are applied to sample preparation process in the area of food safety, environmental science, agriculture, pharmaceuticals and life science.


With knowledgeable scientists and experienced engineers, our R&D team has developed a variety of innovative instruments and solutions dedicated to the modern analytical laboratories.We are committed to provide ONE stop analytical testing solutions corresponding to user requirements with quality and accuracy, but also contribute to human health together.

Headquartered at Xiamen, Fujian China, RayKol group consists of six subcompanies, three research bases and one research institute. Total over 450 employees and 50 external special experts, and we are still growing.

Raykol Patents
Company Culture

 
Mission

Innovation creates values, Knowledge optimized laboratory

 
Vision

World-leading manufacturer and supplier for laboratory automation systems and services

 
Value

Dedication, innovation, motivation, cooperation


Company Certificate

RayKol Group has been certified as SGS Excellent Supplier in China mainland since July 2023.

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA