hwf160-10nh
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Sintering
Electric
Vacuum/Nitrogen/Hydrogen
500*500*650mm(W*H*D)
Chitherm
Wooden Packaging
1650*1950*2000mm(W*H*D)
China
8514101000
Product Description
1. Application:
This furnace is mainly designed for soldering process of metal parts and HTCC package, also can be used in other processes such as decarburization, annealing, quenching, scorching, hardening, thermal decomposition.
2. Technical Specification:
- Rated Temp.: 900ºC
- Max Temp.: 1000ºC
- Atmosphere: N2, H2, with humidification
- Oxygen Content: Measured by O2 content analyzer
- Muffle Material: SUS 310S
- Muffle Dimensions: φ750mm×900mm(d×D)
- Effective Chamber Dimensions: 500×500×650mm(W×H×D)
- Loading Method: Manual, through horizontal guideway shelves
- Heating Method: Resistance wire pre-built heating plate
- Cooling Method: Air cooling with blower
- Temp. Control Stability: ± 1ºC(controller with P.I.D function)
- Profile Steps: Default 20 steps
- Temp. Uniformity: ± 5ºC
- Thermcouple: Type K
- Temp Control: 3 Points
- Temp. Measurement: 1 Point
- Max. Heating Power: 40kW
- Typical Insulation Power: ≤ 25kW
- Heating Speed: ≤ 5ºC/min
- Furnace Surface Temperature: ≤ 40ºC
- Max Vacuum Value: ≤ 10Pa
- Exhaust System: 1 exhaust port on the top with H2 igniter
- Alarm System: audible and visual alarm in case of over temp, thermcouple broken, low air pressure, low water pressure, substandard vacuum level, etc
- Weight: 1500kg
- Appearance Colour: Light Grey
- External Dimensions: 1650mm×1950mm×2000mm (W×H×D)

3. Delivery List
Table 1 Delivery list | |||
Item | Note | Qty. | |
Basic Components | Furnace | 1 SET | |
inspection certificate | Certificate of major outsourced components | 1 SET | |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET | |
Key Components | Heating Element | FEC ceramic fiber heater | 1 SET |
Vacuum System | 1 SET | ||
Touch Screen | 1 SET | ||
Temperature Controller | Azbil | 1 SET | |
Thermocouple | Type K | 1 PCS | |
PLC | 1 SET | ||
Spare Parts | SSR | 1 PC |
4. Facility Requirements
- Environmental Conditions: temp.: 0~40ºC, humidity ≤ 80%RH, no corrosive gas, no strong airflow disturbance.
- N2 Conditions: 99.999% purity, working pressure: 0.2-0.4MPa, Max gas consumption 2-6 m3/h.
- H2 Conditions: working pressure: 0.2-0.4MPa, Max gas consumption 1-3m3/h.
- Water Conditions: clean, no corrosive water, working pressure 0.1-0.3MPa, 3-9L/min
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 15m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 500 kg/m2;
- Power Condition(TBD): capacity > 55kVA, 3-phases 5-lines, voltage 220/380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site: 3000mm×2500mm×3000mm(D×W×H), with an installation area greater than 7.5m2.