Mbf22-10
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Sintering
Electric
Nitrogen
330*200*330mm(W*H*D)
Chitherm
Wooden Packaging
1300*1900*1160mm(W*H*D)
China
8514101000
Product Description
1. Applications:
Mainly used for electronic components, ceramic filters in high temperature binder burn off and sintering process.
2. Mainly Specifics:
- Rated Temp:850ºC
- Max Temp: 1000ºC
- Effective Dimensions: 330 × 200 × 330mm(W×H×D)
- Heating Method: ceramic tube-encased silicon carbide rod.
- Process Atmosphere: Nitrogen
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
- Temperature Uniformity: better than ±3ºC .
- Thermocouple: Type N
- Temperature control points: 1 points
- Temperature measurement points: 1 point
- Process Steps: 4×16 steps
- Oxygen Content: ≤ 20ppm+gas supply oxygen content
- Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection, over temperature heating power will turn off automatically
- Max Heating Power: 12kW
- Surface Temperature Rise: ≤ 40ºC
- Weight: about 650kg
- Furnace Dimensions: about 1300*1900*1160mm (W×H×D);
- Appearance Color: light gray
3. Delivery List | |||
Item | Note | QTY | |
Basic Compositions | Furnace | 1 PC | |
Certificates of Inspection | Furnace and major purchased components | 1 Set | |
Technical Documents | Furnace specifications, technical documents of major purchased components, etc | 1 Set | |
Key Parts | ceramic tube-encased silicon carbide rod | SiC silicon carbide rod | 1 Set |
Touch Screen | 1 PC | ||
Temperature Controller | Azbil | 1 Set | |
micro-oxygen analyzer | 1 Set | ||
Spares | silicon carbide rod | 1 PC |
4. Facility Requirements
4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 2 - 5m3 /h.
4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 10m3 /h;
4.5 Power conditions: capacity greater than 16kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2000mm×2000mm×3000mm (W×H×D), installation area greater than 4m2.