100A 2p 4p Waterproof Leakage Current Circuit Breaker Multifunction RCBO

Price $20.75 Compare
Min Order 2000 Pieces
Shipping From Zhejiang, China
Popularity 327 people viewed
Quantity
+-
 

Wenzhou Santuo Electrical Co., Ltd.

VIP   Audited Supplier 9 years
Profile Certified by SGS/BV
STFS2-100
Low Voltage Circuit Breakers
Manual Type
High-Speed Circuit Breaker
Air
Fixed
ELCB
4
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
ISO9001-2000, CE
IEC61009.1,GB16917.1
16,20,25,32 ,40; 63,80,100
230/400V
4p+PE
30,100,300mA
SONTUOEC, WZSTEC, SONTUNE, IMDEC
Inner Box/Carton
100pcs/ctns
Wenzhou Zhejiang
8536200000
Product Description
Product Description

 The multifunction RCBO has the function of overload,leakage current, temperature protection, rated current/ leakage current /Temperature adjustable;over/under voltage protection;Water proof Protection.

 The working reference temperature of RCBO is 30ºC , when the   ambient temperature changes, its setting value should be corrected. If multiple RCBOs are installed in a closed box and the temperature  inside the box rises, the rated current should be multiplied by the
derating factor of 0.8.
 The "N" line on the RCBO should be connected to the neutral line to make the electronic circuit work normally and play a prote- ctive role.
 It is not allowed to use the method of short-circuiting the phase   line to the neutral line or the phase line to the phase line to carry out the short-circuit protection capability test on the RCBO.
 Recommended selection principles
 General selection principles
a)The rated working voltage of RCBO ≥ the rated voltage of the line.
b) The rated current of RCBO is 1.1-1.25 times the load current calculated by the line.
c)The rated short-circuit breaking capacity of RCBO ≥ the maximum short-circuit
current that may appear in the line.
d)RCBO instantaneous release setting current ≤ 0.8 times the end of the line phase
-to-ground or phase-to-phase short circuit current.
e) Single-phase rated current of electric heaters, refrigerators and incandescent la-
mps at a given voltage and power In=P/U; three-phase rated current In=P/1.732U.
RCBO residual current is generally selected as 30mA, which is used as personal
contact protection.
To install and use the product, please read the retention manual.









LQB5LE-100 leakage circuit breaker user's Guide:

Warn!

1. This product must be wired and installed by qualified personnel;
2. It is strictly forbidden to operate the leakage circuit breaker with wet hands,
otherwise electric shock accidents may occur;
3. Leakage circuit breakers cannot be used for personal electric shock caused by
simultaneous contact with the two lines of the protected circuit. Protect;
4. When the leakage circuit breaker is used for the action characteristic test, it
should be tested and qualified by the relevant state departments. It is strictly
forbidden to use the test method of directly touching the grounding device or direct
short circuit;
5. It is strictly forbidden to directly test the insulation resistance at the outlet of the
product; the power supply of the electronic circuit board should be disconnected,
And ensure that there is no voltage at the input and output terminals of electronic
components before testing, otherwise the circuit board will be burned electronic co-
mponents;
6. The overload, short circuit and residual current protection characteristics of the
leakage circuit breaker are all set by the manufacturer. It is allowed to disassemble
and adjust at will;
7. After the leakage circuit breaker is opened due to the failure of the protected circuit
(leakage, overload or short circuit, etc.), The reason must be
found out, and the closing operation can only be performed after troubleshooting:
8. It is strictly forbidden to connect the load when the leakage circuit breaker is closed:
9. During use, there should be no phase failure or "N" wire disconnection on the power
supply side. Wiring, this product cannot play the role of leakage protection.
Precautions!
1. Leakage circuit breakers must not be attacked by rain or snow during transportation,
storage and use.
2. Before installation, check whether the basic technical data of the signs and signs
meet the requirements (the selected current The size should match the actual use):
manual operation several times should be flexible, confirm that it is intact, Installation:
When installing, wires that can withstand the corresponding current carrying capacity
should be selected. See attached table 3 for reference values.
3. Strictly follow the wiring diagram for installation.
4. Run check: 4.1 Check whether the wiring is correct, especially check that the
input terminal of the leakage circuit breaker should be connected to the power supply,
and the output terminal should be connected to the load.
4.2 Confirm that the screws of each terminal have pressed the wire tightly, and the  wire
should be in the corresponding wiring frame.
4.3 Close the leakage circuit breaker and press the test button to check whether the
leakage protection performance is normal and reliable. If the leakage circuit
breaker can be disconnected normally, the indicator will be red.
5. After the leakage circuit breaker has been running for a certain period of time
(usually one month), it is necessary to press the test button in the closed and energ-
ized state to check whether the leakage protection performance is normal andreli-
able (press the test button once a month, and the leakage circuit breaker should be
broken once). In case of failure, it should be removed and sent to the manufacturer
for repair.
6. The neutral wire () at the outlet end can only be used as a working neutral wire, not
a protective neutral wire. 7. When the leakage exitable model is selected, the leakage
"exit" function of the circuit breaker is an emergency use function, which is only used
by professional power supply maintenance personnel in emergency maintenance situations.
After maintenance, it must be put into leakage protection function status immediately.


Product Over View:  

1.Provide protection against earth fault/leakage current and function of isolation

2.High short-circuit current withstand capacity

3.Applicable to terminal and pin/fork type busbar connection

4. Equipped with finger protected connection terminals

5.Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity6.Independent of power supply and line voltage, and free from external interference, voltage fluctuation.

SPECIFICATIONS
 Standard UnitIEC/EN 61009-1

Electrical

features

Mode  Electronic type
Type(wave form of the earth leakage sensed) A, AC
Thermo-magnetic release characteristic B,C,D
Rated current lnA6,10,16,20,25,32,40,63;80,100
PolesP1P+N, 3P+N
Rated voltage UeVAC 230, 400
Rated sensitivity I△nA0.01, 0.03, 0.1, 0.3, 0.5
Rated residual making and breaking capacity l△mA500
Rated short-circuit capacity IcnA6000
Break time under I△nS≤0.1
Rated frequencyHz50/60
Rated impulsewithstand voltage(1.2/50)UimpV4000
Dielectric test voltage at ind.Freq for 1minkV2
Insulation voltage UiV250
Pollution degree 2
OtherOver/under voltage protection;  Temperature ; Fire-alwarm 

Mechanical

features

Electrical life 4000
Mechanical life 10000
Fault current Indicator YES

Protection degree

 

IP20

Ambient temperature

(with daily average≤35ºC)

ºC

-5~+40(Special application please refer to

temperature compensation correction)

Storage temperatureºC-25~+70
InstallationTerminal connection type Cable/Pin-type busbar/U-type busbar
   
Terminal size top/bottom for cablemm225
AWG18-5
Terminal size top/bottom for busbarmm225
AWG18-3
Mounting On DIN rail EN 60715(35mm)by means of fast clip device
Connection From top



Our Services:

  1. Competitive price
  2. Continuance Service and support
  3. Good-after service
  4. Quality Reliability and Long Product Life.

 

FAQ
 

Q1. What advantages do you have?

A1. We are the direct Manufacturer in Wenzhou China , we have professional,our teams have more than 20years experience in the field.
developing, marketing & production team to offer you the most competitive price and best service.

Q2. What's your main product?
A2. Circuit Breaker(MCB,RCCB/RCD, RCBO,ELCB, MCCB, ACB); Ac Contactor, Thermal Relay, Magnetic Starter; Isolator Switch, Changeover Switch, Push Button Switch, Voltage Protector...

Q3. Could you print our own logo?
A3. Yes, Our company are available for Retail & Wholesale & OEM & ODM.

Q4. How long is the quality guarantee?
A4. 18 month warranty, our products are 100% inspection.

Q5. How long is the deliver time?
A5. It usually takes about 3 - 5 working days for sample order and 10 - 25 days for big order.

Q6. What is your payment terms?
A6. Our Payment term is T/T,  PayPal,  L/C at sight.

Q7. Any certification of your company or product?
A7.We have ISO 9001, CE, CB, SEMKO, SAA, TUV.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA