100kVA-3000kVA 3 Phase Silent Electric Generac Diesel Power Generator with Cummins Perkins Mtu Mitsubishi Sme Sdec Yuchai Weichai Chinese Engine for Sale

Price $200000.00 Compare
Min Order 1 SET
Shipping From Fujian, China
Popularity 470 people viewed
Quantity
+-
 

Mecca Power Co., Limited

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
MC
Responsible
12 Months or 1200 Operation Hours
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Low Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
Static Exciter
Cummins Perkins Yuchai Sdec Yto Weichai FAW
Stamford / Leroy Somer /Mecc Alte
UK Deepsea, Smartgen, Optional
Three Phase Generator Price
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
50Hz/60Hz, 1500rpm 1800rpm
110-480V, 3.3kv-13.8kv Medium High Voltage
Telecom/Mining/Construction/Data Center
Commercial/Power Plant/Factory/Industrial
Spare Parts Documents
Mech/Elec/ECU/Ecm/Adec/Hpcr
Industrial Power Generator Set
CE, ISO, OEM Authorization etc.
Power Genset Unit
Electrical Diesel Generating Set
Mecca
Both Standard Marine Packing or Compact Packing.
As below Spec. with details
China
850211
Product Description
Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan, FPT,Mitsubishi,Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc. Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, mining,power plant, etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.


Generator Introduction

MECCA POWER MEI 2020 REWARDED Low Fuel Consumption DIESEL GENERATOR

MECCA POWER offer diesel generator 10-4000kva, with all engine brand like Cummins/Perkins/Mitsubishi/MTU/Baudouin/Volvo/FPT,Chinese engine brand Yuchai,SDEC,FAW,Weichai,Yangdong,etc.

Specification
Powered by DCEC CUMMINS Series                                                                                                             50HZ   220-440 V 22-550KVA 
ModelLTPPRPEngineFuel Cons.L/HCylinderDisplacementGov.
KVA / KW KVA/KW ModelOrigin100%L
MC22C2217.620164B3.9-G11CN5.74L3.9 M
MC30C30 24 28 224B3.9-G1CN7.14L3.9 M
MC30C30 24 28224B3.9-G2CN6.74L3.9 E
MC33C33 26 30244B3.9-G12CN7.44L3.9 E
MC44C44 35 40324BT3.9-G1CN10.04L3.9 M
MC44C44 35 40324BT3.9-G2CN9.34L3.9 E
MC55C55 44 50404BTA3.9-G2CN12.94L3.9 E
MC63C63 50 56 454BTA3.9-G2CN12.94L3.9 E
MC88C88 70 80644BTA3.9-G11CN17.64L3.9 E
MC105C105 84 95764BTA3.9-G13CN18.84L3.9 E
MC110C110 88 100804BTA3.9-G13CN24.74L3.9 E
MC103C103 82 94756BT5.9-G1CN21.76L5.9 M
MC103C103 82 94756BT5.9-G2CN24.26L5.9 E
MC115C115 92 105846BT5.9-G2CN24.26L5.9 E
MC125C125 100 115926BTA5.9-G2CN31.06L5.9 E
MC145C145 116 1351086BTAA5.9-G2CN34.06L5.9 E
MC165C165 132 1501206BTAA5.9-G12CN34.06L5.9 E
MC200C200 160 1801456CTA8.3-G1CN42.06L8.3 M
MC200C200 160 1801456CTA8.3-G2CN42.06L8.3 E
MC215C215 172 2001606CTAA8.3-G2CN45.06L8.3 E
MC250C250 200 NANA6CTAA8.3-G9CNNA6L8.3 E
MC264C264 211 2502006LTAA8.9-G2CN53.06L8.9 E
MC275C275 220 2502006LTAA8.9-G3CN54.06L8.9 E
MC300C300 240 2702166LTAA9.5-G3CN58.06L9.5 E
MC350C350 280 3202566LTAA9.5-G1CN70.06L9.5 E
MC425C425 340 3883106ZTAA13-G3CN76.56L13.0 E
MC475C475 380 4383506ZTAA13-G2CN89.16L13.0 E
MC475C475 380 4383506ZTAA13-G4CN91.46L13.0 E
MC468C468 375 438350QSZ13-G2CN88.86L13.0 ECU
MC500C500 400 450360QSZ13-G5CN93.26L13.0 ECU
MC500C500 400 475380QSZ13-G3CN101.06L13.0 ECU
MC550C550 440 500400QSZ13-G10CN1076L13.0 ECU
StageIII
MC66C66 53 60 48QSB3.9-G2CN184L3.9 ECU
MC88C88 70 8064QSB3.9-G3CN20.14L3.9 ECU
MC110C110 88 10080QSB5.9-G2CN266L5.9 ECU
MC138C138 110 125100QSB5.9-G3CN316L5.9 ECU
MC165C165 132 150120QSB6.7-G3CN386L6.7 ECU
MC198C198 158 180144QSB6.7-G4CN436L6.7 ECU
MC220C220 176 200160QSL8.9-G2CN556L8.9 ECU
MC248C248 198 225180QSL8.9-G3CN576L8.9 ECU
MC275C275 220 250200QSL8.9-G4CN606L8.9 ECU
MC395C395 316 360288QSZ13-G6CN81.66L13.0 ECU
MC438C438 350 400320QSZ13-G7CN89.26L13.0 ECU
Powered by  CCEC CUMMINS Series                                                                        50HZ   220-440 V 22-550KVA      
ModelLTPPRPEngineFuel Cons.CylinderDisplacementGov.
KVA / KW KVA/KW ModelOriginL/H (100%)L
MC275C275 220 250200NT855-GACN53.46L14E
MC275C275 220 250200MTA11-G2CN596L10.8E
MC275C275 220250200NTA855-G1CN59.26L14E
MC313C313 250275220NTA855-G1ACN61.36L14E
MC350C350 280 313250MTAA11-G3CN62.0 6L10.8E
MC350C350 280 313250NTA855-G1BCN71.46L14E
MC350C350 350313250NTA855-G2CN71.46L14E
MC375C375 300344275NTA855-G2ACN71.96L14E
MC385C388 310 350280NTA855-G4CN75.36L14E
MC413C413 330 375300NTAA855-G7CN85.46L14E
MC450C450 360 N.A.N.A.NTAA855-G7ACN89.26L14E
MC413C413 330 375300KTA19-G2CN836L18.9E
MC500C500 400 450360KTA19-G3CN976L18.9E
MC563C563 450 500400KTA19-G3ACN108.36L18.9E
MC563C563 450 500400KTA19-G4CN1076L18.9E
MC631C631 505 525420KTAA19-G5CN112.96L18.9E
MC650C650 520 575460KTAA19-G6CN118.56L18.9E
MC650C650 520N.A.N.A.KTA19-G8CNN.A.6L19E
MC687C687 550N.A.N.A.KTAA19-G6ACNN.A.6L19E
MC700C700 560 625500KT38-GCN14012V37.8E
MC788C788 630713570KTA38-G1CN16212V37.8E
MC788C788 630713570KTA38-G1BCN152.4 12V37.8E
MC800C800 640 725580KT38-GACN169.9 12V37.8E
MC825C825 660 750600KTA38-G2CN16912V37.8E
MC888C888 710 800640KTA38-G2BCN169.312V37.8E
MC1000C1000 801 910728KTA38-G2ACN196.512V37.8E
MC1100C1100 880 1000800KTA38-G5CN21212V37.8E
MC1250C1250 1000 N.A.N.A.KTA38-G9CNN.A.12V37.8E
MC1375C1375 1100 12501000KTA50-G3CN26116V50.3E
MC1375C1375 110012751020KTA50-G12CN24916V50.3E
MC1600C1600 128013751100KTA50-G12ACN279.8 16V50.3E
MC1650C1650 1320 13751100KTA50-G8CN28916V50.3E
MC1650C1650 1320 15001200KTA50-GS8CN30916V50.3E
MC1875C1875 1500 16751340KTA50-G15XCN36616V50.3E
Stage III
MC275C275 220250200QSNT-G6CN61.9 6L14ECM
MC313C313 250275220QSNT-G7CN67.4 6L14ECM
MC350C350 350313250QSNT-G1CN75.0 6L14ECM
MC388C388 310 350280QSNT-G2CN148.86L14ECM
MC438C438 350 400320QSNT-G3CN87.46L14ECM
MC500C500 400 450360QSK19-G14CN99.76L18.9ECM
MC500C500 400 455364QSK19-G15CN1056L18.9ECM
MC550C550 440 500400QSK19-G16CN1126L18.9ECM
MC563C563 450 500400QSK19-G13CN109.56L18.9ECM
MC625C625 500 569455QSK19-G17CN1256L18.9ECM
MC631C631 505 575460QSK19-G12CN128.36L18.9ECM
MC650C650 520 588470QSK19-G6CN129.66L18.9ECM
MC700C700 560 636509QSK19-G18CN1366L18.9ECM
MC713C713 570 650520QSK19-G4CN1456L18.9ECM
MC750C750 600681545QSK19-G19CN1436L18.9ECM
MC750C750 600688550QSK19-G11CN153.86L18.9ECM
MC825C825 660750600QSK19-G20CN1556L18.9ECM
MC825C825 660750600QSK38-G8CN16812V37.8ECM
MC888C888 710813650QSK38-G7CN18012V37.8ECM
MC900C900 720819655QSK19-G21CN1676L18.9ECM
MC1000C1000 800910728QSK38-G6CN19712V37.8ECM
MC1000C1000 800910728QSK38-G9CN21612V37.8ECM
MC1100C1100 880 1000800QSK38-G10CN23212V37.8ECM
MC1100C1109 8871008806QSK38-G1CN21212V37.8ECM
MC1250C1250 1000 1136909QSK38-G11CN25512V37.8ECM
MC1259C1259 10071144915QSK38-G2CN23512V37.8ECM
MC1375C1375 1100 12501000QSK38-G5CN27412V37.8ECM
MC1400C1400 1120 12731018QSK38-G12CN27412V37.8ECM
MC1500C1500 120013751100QSK38-G19CN28812V37.8ECM
MC1540C1540 123214001120QSK38-G13CN29112V37.8ECM
MC1675C1675 1340 15231218QSK38-G14CN32912V37.8ECM
MC1760C1760 1408 16001280QSK38-G15CN33412V37.8ECM
MC1825C1825 146016501320QSK50-G7CN34916V50.3ECM
MC1875C1875 1500 16751340KTA50-G15ACN35716V50.3E
MC2000C2000 1600 18751500KTA50-G16ACN40016V50.3E
Powered by CUMMINS G-DRRIVE Series                                                                             50HZ   220-440 V 22-550KVA      
ModelLTPPRPEngineEmission
KVA / KW KVA/KW ModelOrigin
MC90C90 72 8266QSB5-G3 US/UKS IIIA,Tier3
MC100C100 80 9173QSB5-G4US/UKS IIIA,Tier3
MC110C110 88 10080QSB5-G5 US/UKS IIIA,Tier3
MC150C150 120 136109QSB5-G6US/UKS IIIA,Tier3
MC150C150 120 137.5110QSB7-G2US/UKS IIIA,Tier3
MC175C175 140 150120QSB7-G3 US/UKS IIIA,Tier3
MC200C200 160 180144QSB7-G4 US/UKS IIIA,Tier3
MC220C220 176 200160QSB7-G5 US/UKS IIIA,Tier3
MC250C250 200 225180QSL9-G2 US/UKS IIIA,Tier3
MC275C275 220 250200QSL9-G3 US/UKS IIIA,Tier3
MC300C300 240 275220QSL9-G4US/UKS IIIA,Tier3
MC330C330 264 300240QSL9-G5 US/UKN.A.
MC330C330 264 300240QSL9-G7US/UKS IIIA,Tier3
MC450C450 360 400320QSX15-G4USS II/Tier2
MC500C500 400 455364QSX15-G6USS II/Tier2
MC550C550 440 500400QSX15-G8USS II/Tier2
MC500C500 400 455364QSX15-G13USS IIIA,Tier3
MC550C550 440 500400QSX15-G16USS IIIA
MC700C700 560 636509VTA28-G5INN.A.
MC825C825660 N.A.N.A.VTA28-G6INN.A.
MC800C800 640 725580QSK23-G2INN.A.
MC810C810 650 750600QSK23-G2INN.A.
MC880C880 704 800640QSK23-G3 INN.A.
MC900C900 720 810648QSK23-G3 INN.A.
MC813C813 650 750600QSK23-G8INTier2
MC900C900 720 810648QSK23-G9INTier2
MC1000C1000800 910728QST30-G3USN.A.
MC1100C1100880 1000800QST30-G4USN.A.
MC1000C1000800 910728KTA38-G3INN.A.
MC1132C1132 906 1029823KTA38-G5INN.A.
MC1250C12501000 N.A.N.A.KTA38-G9INN.A.
MC1250C12501000 1135908QSK38-G2 UKTier2
MC1375C13751100 12501000QSK38-G3UKTier2
MC1400C1400 1120 12751020QSK38-G5 UKTier2
MC1400C1400 1120 12751020KTA50-G3INN.A.
MC1500C1500 1200 13751100KTA50-G8INN.A.
MC1675C1650 1320 N.A.N.A.KTA50-G8INN.A.
MC1675C1675 1340 15001200KTA50-GS8INN.A.
MC1540C1540 1232 14001120QSK50-G3 UK/CNTier2
MC1700C1700 1360 15401232QSK50-G4 UK/CNTier2
MC1825C1825 1460 16501320QSK50-G7 UK/CNTier2
MC2000C2000 1600 18751500QSK60-G3UK/INN.A.
MC2000C2000 1600 18751500QSK60-G7UK/INN.A.
MC2250C2250 1800 20451636QSK60-G4UK/INN.A.
MC2500C2500 2000 22501800QSK60-G8UK/INN.A.
MC2250C2250 1800 20001600QSK60-G11 UK/IN4g TA
MC2500C2500 2000 20001600QSK60-G13 UK/IN4g TA
MC2500C2500 2000 22501800QSK60-G21UK/INTier2
MC2750C2750 2200 25002000QSK60-G23UK/IN/CNT2
MC2750C2750 2200 25002000QSK78-G18UKN.A.
MC3000C3000 2400 27502200QSK78-G9UKN.A.
MC3000C3000 2400 27502200QSK78-G15UKTier 2
MC3300C3300 2640 30002400QSK95-G5US2g TA Luft
MC3500C3500 2800 31252500QSK95-G5US2g TA Luft
MC3760C3760 3010 33602690QSK95-G4USN.A.
MC3750C3750 3000 33502680QSK95-G10USTier 2

MORE SPEC. CONTACT US...

Genset Workshop

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.



-----------------------------------------------------------------------------------------------MAINTENANCE---------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary