RSP-750
Single
5 Years
750W
Full Range
Series Switching Power Supply
Self-excited Switching Power Supply
Width Modulation Type
One-way Transmission
PWM
CE, RoHS, CCC, FCC
MEAN WELL
180-264VAC 254-370VDC
47-63Hz
91.5%
60A/230VAC
-20~+70ºC(Refer to "Derating Curve")
250*127*41mm(L*W*H)
1.64kg;6PCS/10.8kg/1.1cuft
MEAN WELL
Carton Packing
250*127*41mm
Taiwan
8504401400
Product Description
MEAN WELL RSP-750 750W 12V 15V 24V 27V 48V AC to Dc High Efficiency Programmable Switching Power Supply
Features:
1. AC input 180~264VAC
2. AC input active surge current limiting
3. High efficiency up to 91.5%
4. 5 years warranty
1. AC input 180~264VAC
2. AC input active surge current limiting
3. High efficiency up to 91.5%
4. 5 years warranty
MODEL | RSP-750-5 | RSP-750-12 | RSP-750-15 | RSP-750-24 | RSP-750-27 | RSP-750-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | 100A | 62.5A | 50A | 31.3A | 27.8A | 15.7A | |
CURRENT RANGE | 0~100A | 0~62.5A | 0~50A | 0~31.3A | 0~27.8A | 0~15.7A | |
RATED POWER | 500W | 750W | 750W | 751.2W | 750.6W | 753.6W | |
RIPPLE&NOISE(max.)Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ.RANGE | 4.75~5.5V | 10~13.5V | 13.5~16.5V | 20~26.4V | 24~30V | 43~55V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | 1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOADREGULATION | ±2.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISETIME | 1000ms,50ms at full load | ||||||
HOLDUPTIME(Typ. | 16ms/230VAC 16ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE Note.4 | 90~264VAC 127~370VDC | |||||
FREQUENCY RANGE | 47~63Hz | ||||||
POWER FACTOR(Typ.) | 0.97/230VAC 0.98/115VAC at full load | ||||||
EFFICIENCY(Typ.) | 82% | 87% | 89% | 90.5% | 90.5% | 92% | |
AC CURRENT (Typ.) | 5V:5.6A/115VAC 2.8A/230VAC 12V~48V:8.2A/115VAC 3.9A/230VAC | ||||||
INRUSH CURRENT(Typ.) | 25A/115VAC 40Al230VAC | ||||||
LEAKAGE CURRENT | <2.0mA/240VAC | ||||||
PROTECTION | OVERLOAD | 105~125%rated output power | |||||
Protection type:Constant current limiting,recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE(OVP) | 5.75~6.75V | 13.8~16.8V | 17~20.5V | 27.6~32.4V | 31~36.5V | 56.6~66.2V | |
Protection type:Shut down o/p voltage,re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage,recovers automatically after temperature goes down | ||||||
FUNCTION | 0UTPUTVOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltage is allowable to 40~110%of nominal output voltage.Please referto the Function Manual. | |||||
CONSTANT CURRENTLEVELPROGRAMABLEPC | Adjustment of constant current level is allowable to 40~110%of rated current.Please refer to the Function Manual. | ||||||
AUXILIARY POWER | 12V@0.1A;tolerance:±10% | ||||||
REMOTE ON-OFF CONTROL | Power on:short between Remote ON-OFF(pin13)&12V-AUX(pin14)on CN50 Poweroff:open between Remote ON-0FF(pin13)&12-AUX(pin14)on CN50 | ||||||
DC OK SIGNAL | The TTL signal out,power supply turn on=0~1V;powersupply turn off=3.3~5.6V | ||||||
ENVIRONMENT | WORKING TEMP. | -30~+70ºC(Refer to "Derating Curve") | |||||
WORKING HUMIDITY | 20~90%RH non-condensing | ||||||
STORAGETEMP.,HUMIDITY | 40~+85ºC,10~95%RH non-condensing | ||||||
TEMP.COEFFICIENT | ±0.03%1ºC(0~50ºC) | ||||||
VIBRATION | 10~500Hz,2G 10min.1cycle,60min.each along X,Y,Z axes | ||||||
SAFETY & EMC (Note 7) | SAFETYSTANDARDS | UL62368-1,CSAC22.2No.62368-1,TUVBS EN/EN62368-1,CCC GB4943.1,BSMICNS14336-1,AS/NZS62368.1,EACTPTC004, BIS IS13252(Part1):2010/IEC60950-1:2005(except for 48V)approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC /P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC125ºC/70%RH | ||||||
EMC EMISSION | Parameter | Standard | Test Level /Note | ||||
Conducted | BS EN/EN55032(CISPR32) | Class B | |||||
Radiated | BS EN/EN55032(CISPR32) | Class B | |||||
Harmonic Current | BS EN/EN61000-3-2 | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | ||||||
EMC IMMUNITY | BS EN/EN55024,BS EN/EN61000-6-2,CCC GB17625.1,GB/T9254,BSMICNS13438 | ||||||
Parameter | Standard | Test Level /Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3,8KVair;Level2,4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | |||||
Surge | BS EN/EN61000-4-5 | Level 4,4KV/Line-Earth;Level3,2KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95%dip 0.5 periods,30%dip 25 periods, >95%interruptions 250 periods | |||||
OTHERS | MTBF | 336.9K hrs min.Telcordia SR-332(Bellcore);109.1K hrs min.MIL-HDBK-217F(25ºC) | |||||
DIMENSION | 250*127*41mm(L*W*H) | ||||||
PACKING | 1.64Kg;6pcs/10.8Kg/1.1CUFT | ||||||
NOTE | 1.All parameters NOT specily mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple &noise are measuredat 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1μF&47μF parallel capacitor. 3.Tolerance :includes setup tolerance,line regulation and load regulation. 4.Derating may be needed under lowinput voltages.Please check the derating curve for more details. 5.There is high possibiy to tigger the floatng over voltage protecion when PV voltage is timmed from a highvotage level o alower votage level at ight load or no load condition.Itis suggested that turn of the power supply and set PV voltage to the lowest levelthen adjust output otage to a desired value. 6.Strongly recommended that extemal output capacitance should not exceed 5000uF. (Only for:RSP-750-5) 7.The power supply is considered a component wich wil be instlled into a final equipment Al the EMC tests are been executed by mountng the unit on a 720mm*360mm metal plate with 1mm of hickness.Thefial equipment must be re-confrmed hat t sil meets EMC drectives.For guidance on how to perfom theseEMC tests,please refer to "EMI testing of component power supplies. " 8.The ambient temperature derating of 35ºC1000m with fanless modes and of5C1000m with fan models for operatng alitude higher han 2000m(6500f) 9.Products sourced from Taiwan do not have the BIS logo,please contact your MEAN WELL sales for more information. |






