Mean Well 5 Years Warranty 2000W 12V 24V 48V High Efficiency Programmable AC to DC Switching Power Supply

Price $338.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 428 people viewed
Quantity
+-
 

Zhejiang Weihao Electronic Co., Ltd.

VIP   Audited Supplier 15 years
Profile Certified by SGS/BV
RSP-2000
Single
5 Years
2000W
Full Range
Series Switching Power Supply
Self-excited Switching Power Supply
Width Modulation Type
One-way Transmission
PWM
CE, RoHS, CCC, FCC
MEAN WELL
180-264VAC 254-370VDC
47-63Hz
91.5%
60A/230VAC
-20~+70ºC(Refer to "Derating Curve")
250*250*150mm(L*W*H)
2kg;6PCS/12.7kg/1.15cuft
MEAN WELL
Carton Packing
294*185*45mm
Taiwan
8504401400
Product Description
MEAN WELL 5 Years Warranty 2000W 12V 24V 48V High Efficiency Programmable Ac to Dc Switching Power Supply
Features:
1. AC input 180~264VAC
2. AC input active surge current limiting
3. High efficiency up to 91.5%
4. 5 years warranty
Detailed Photos

 

Product Parameters
MODELRSP-2000-12RSP-2000-24RSP-2000-48
OUTPUTDC VOLTAGE12V24V48V
RATED    CURRENT100A80A42A
CURRENT    RANGE0~100A0~80A0~42A
RATED   POWER1200W1920W2016W
RIPPLE&NOISE (max.)Note.2150mVp-p200mVp-p300mVp-p
VOLTAGE    ADJ.RANGE10.5~14V21~28V42~56V
VOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%
LINE REGULATION±1.0%±0.5%±0.5%
LOAD    REGULATION±1.0%±0.5%±0.5%
SETUP,RISE TIME1500ms,60ms/230VACat full load
HOLD UP TIME(Typ.)16ms/230VACat75%load     10ms/230VAC at full load
INPUTVOLTAGE   RANGE  Note.4,590~264VAC    250~320VDC
FREQUENCY    RANGE47~63Hz
POWER FACTOR(Typ.)0.97/230VAC at full load
EFFICIENCY(Typ.)87%90.5%92%
AC CURRENT(Typ.)   Note.413A/115VAC    7A/230VAC16A/115VAC    10A/230VAC16A/115VAC    10A/230VAC
INRUSH CURRENT(Typ.)COLD START 50A
LEAKAGECURRENT<2mA/240VAC
PROTECTIONOVERLOAD105~125%rated output power
Protection type:Constant current limiting,unit will shut down o/p voltage after 5 sec.re-power on to recover
OVER VOLTAGE14.7~17.5V29.5~35V57.6~67.2V
Protection type:Shut down o/p voltage,re-power on to recover
OVER    TEMPERATUREShut down o/p voltage,recovers automatically after temperature goes down
FUNCTION0UTPUTVOLTAGE PROGRAMMABLE(PV)Adjustment of output voltageis allowable to 40~115%of nominal output voltage.Please refer to the Function Manual.
CURRENT    SHARINGUp to 8000Wor (3+1)units.Please referto the Function Manual.
AUXILIARY POWER5V@0.3A,12V@0.8A
REMOTE ON-OFF CONTROLBy electrical signal or dry contact Power ON:open Power OFF:short.Please refer to the Function Manual.
REMOTE    SENSECompensate voltage drop on the load wiring up to 0.5V.Please refer to the Function Manual.
DC OK SIGNALThe isolated TTL signal out.Please refer to the Function Manual.
ENVIRONMENTWORKING TEMP.-35~+70ºC(Refer to "Derating Curve")
WORKING HUMIDITY20~90%RH non-condensing
STORAGE TEMP.,HUMIDITY-40~+85ºC,10~95%RHnon-condensing
TEMP.COEFFICIENT±0.03%/ºC  (0~50ºC)
VIBRATION10~500Hz,2G 10min./1cycle,60min.each along X,Y,Zaxes
SAFETY&

EMC
(Note
  6)
SAFETY    STANDARDSUL62368-1,CSAC22.2 No.62368-1,TUVBS EN/EN62368-1,BSMI CNS14336-1,AS/NZS62368.1,
BIS IS13252(Part1):2010/IEC 60950-1:2005(except 48V),EACTP TC004 approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC125ºC170%RH
EMC EMISSIONParameterStandardTest Level /Note
ConductedBS EN/EN55032(CISPR32)Class B
RadiatedBS EN/EN55032(CISPR32)ClassA
Harmonic CurrentBS EN/EN61000-3-2 
Voltage FlickerBS EN/EN61000-3-3-
EMC IMMUNITYBS EN/EN55035,BS EN/EN61000-6-2,BSMI CNS13438
ParameterStandardTest Level/Note
ESDBS EN/EN61000-4-2Level 3,8KV air;Level2,4KV contact
RadiatedBS EN/EN61000-4-3Level 3
EFT/BurstBS EN/EN61000-4-4Level 3
SurgeBS EN/EN61000-4-5Level4,4KV/Line-Earth;Level 3,2KV/Line-Line
ConductedBS EN/EN61000-4-6Level 3
Magnetic FieldBS EN/EN61000-4-8Level 4
Voltage Dips and InterruptionsBS EN/EN61000-4-11>95%dip 0.5 periods,30%dip 25 periods,
>95%interruptions 250 periods
OTHERSMTBF487.7K hrs min.Telcordia SR-332 (Bellcore);42.9K hrs min.MIL-HDBK-217F (25ºC)
DIMENSION295*127*41mm(L*W*H)
PACKING1.95Kg;6pcs/12.7Kg/1.15CUFT

NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature.
2.Ripple &noise are measuredat 20MHz of bandwidth by using a 12"twisted pair-wire teminated with a 0.1uf &47uf parael capacitor.
3
.Tolerance :includes set up tolerance,line regulation and load regulation.
4.Derating may be needed under low input voltages.Please check the derating curve for more details.
5.Please contact MEANWELL for 320~370VDC application.
6.The power supply is considered a component which wil be instaled into a find equipment Al the EMC tests are been executed by mounting the unit on
a 720mm*360mm metalplate with 1mm of hickness.Thefial equipment must be re-confirmed that itstll meets EMC drectives.For guidance on how to
  perform these EMC tests,please refer to  "EMI testing of component power supplies. "
7.The ambient temperature derating of 3.5ºC/1ooom with fanless models and of 5ºCA000m with fan models for operating alftude higher than 2000m

 



Message Type