ACEY-ACTS-20V5A-GGS
Provided
1 Year
Charge and Discharge
Lithium-ion Battery
Customized
8chs/Module
Hybrid Battery Reconditioning Equipment
AC220V, Frequency50Hz
Li-ion/Lead-Acid/Ni-CD/NiMH Battery and So on
0.02%Fs
ACEY
Plywood
Xiamen China
Product Description

20V 5A 8-Channel Ni-MH Hybrid Lithium Battery Maintenance Repair Equipment Hev Nicad Car Battery Reconditioner Reconditioning Machine

ACEY-ACTS-20V5A-GGS hybrid battery reconditioning equipment is mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.
Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing.
Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing.
Power supply: AC220V±10%, frequency: 50HZ±5%;
Working temperature: :25ºC±3ºC.
Humidity: ≤ 85%R.H (non-condensing)
No severe shake, no corrosive gases, no flammable or explosive gases around.
No. | Item | ACEY-ACTS-20V5A-GGS | ||
1 | Main channels | 8CH/module | ||
2 | Channels working mode | Independently | ||
3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV | ||
Discharge: CD, CP, CR | ||||
Still | ||||
Ending condition of main channel | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, Temperature (NTC detection temperature and GGS temperature), etc. | |||
4 | Main channel Voltage | Test range of voltage | 0V-20V | |
Min. discharge voltage | 1.5V | |||
Accuracy | ±0.02%FS+0.02%RD(@25±3ºC) | |||
Resolution | 0.1mV | |||
Main channel Current | Test range of current | ±5A | ||
Min. output current | 20mA | |||
Accuracy | ±0.02%FS+0.02%RD(@25±3ºC) | |||
Resolution | 1mA | |||
Current start response time | <10ms | |||
Time | Resolution | 10ms | ||
Power | Output power | Single channel continuous working power 100W | ||
Stability | ±0.05%FS+0.05%RD | |||
Auxiliary channel parameter cutoff function | Main channel step can be set to stop or jump when auxiliary channel signal reach to a certain condition. | |||
5 | ACTS Communication | LAN | ||
6 | GGS Communication (Optional) | SMBUS, I2C, HDQ | ||
Support reading 100kHz and 400kHz communication frequency battery information (software can be set and switched) | ||||
Support single channel independent operation of different data communication protocols. (If GGS communication and INA231 communication are selected) | ||||
Support multi-channel simultaneous sampling, and the data recording interval of the same channel is ≥ 1s (The same table as the charge and discharge data) | ||||
7 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
Cycle time | Max. 9,999 | |||
Programmable step | Max. 9,999 | |||
Nested loop | Max. 10 layers | |||
Step time range | No limit, support h, min, s | |||
Data record | Maximum recording time:10ms, voltage≤0.02%FS, current ≤0.02%FS | |||
Program feature | Each step has one or multiple exit | |||
Barcode scan | Support | |||
8 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
Process list | Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc. | |||
Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
9 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
10 | Data saving | Save as files | ||
11 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time | ||
Y-coordinate: total voltage, current, capacity, power, cell temperature | ||||
12 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP. | |||
Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
13 | Sampling terminals | Four-polar sampling. Crocodile clip or other clips. | ||
14 | Energy consumption | Heat dissipation | ||
15 | Cooling method | Forced Fan-cooled | ||
16 | Voice | Less than 70dB(Single set) | ||
IP grade | IP20 | |||
17 | Repair | Modularized structure. Can be replaced or repair with spare parts. |
















A: Please send us your purchase order by email or call us sales, or we can make the proforma invoice under your request.We need to know the following information for your order before sending your Pl. Payment methods? T/T, L/C, D/P and so on.
1)Product information-quantity, specification(size, material, technological if needed and packing requirements etc.)
2)Shipping information-company name, street address, phone number,destination sea port.
Q2: How to control quality?
A,All the raw materials by IQC(Incoming Quality Control) before launch whole process into the process after the screening,
B, Process each ink in the process of IPQC(Input Process Quality Control)patrol inspection.
C, After finished by QC full inspection before packing into the next process packing.
D, OQC before shipment for each slipper to do full inspection.
Q3:How do I install and operate the machine myself?
A: Our system development is based on the integrated development view, when you get the machine, just connect it to the power supply and the machine is ready to work, as the English software is already installed on the machine, all you need to do is to learn how to use the software, a complete English user manual will be sent to you with the machine.
Q4: How do I get technical support after purchase?
A: Our factory provides online technical support in English, you can get to know us easily online through Skype, Wechat, WhatsApp or E-mail. If you need any remote assistant support, we will support you through Team viewer software.
Q5:What's the warranty for the items?
A: We are very confident in our products and we package them very well so you will usually receive your order in perfect condition. The warranty on the equipment is one year (12 months) and if any part of the equipment is damaged within one year due to non-human factors, we will provide a replacement part free of charge.
Q6:Can I customize products?
A: Yes, OEM&ODM is available! we can provide not only standard machines but also customized machines according to your requirements. Don't hesitate to tell us your requirement, we will try our best to meet your needs.