Factory Eto Gas Sterilizer, Ethylene Oxide Sterilization Equipment

Price $100000.00 Compare
Min Order 1 Piece
Shipping From Henan, China
Popularity 493 people viewed
Quantity
+-
 

Henan Huatai Cereals and Oils Machinery Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
Pneumatic
Gas Sterilization Equipments
CE
380V
With LCD Display
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Stainless Steel
30ºC~50ºC
3-99 Hours Adjustable
Anti-Corrosion SS304
4600kg
10000*5000*3000mm
Angel
Henan, China
Product Description
Ethylene Oxide Sterilizer Machine Manufacturer
Description of ethylene oxide sterilizer
The HTAJ3 large-scale ethylene oxide sterilizer is a marvel of low-temperature sterilization technology. Crafted with cutting-edge computer automation, welding expertise, and innovative processes, this machine leverages global advancements to ensure superior performance and reliability. Experience the fusion of domestic and international excellence in sterilization with this sophisticated equipment.


Precautions
(1) Installation requirements of ethylene oxide sterilizer: For optimal safety and functionality, the ethylene oxide sterilizer should be installed in a well-ventilated location, away from any fire hazards. Allow a clearance of 51cm on all sides, including the top, to enable easy maintenance and repairs. Ensure special exhaust pipes are installed, completely segregating them from other building exhaust systems to maintain a safe environment.
(2) Ethylene oxide safety protection principles and precautions:
1) Keep all ethylene oxide sterilizers and storage containers at a safe distance from ignition sources and static electricity to prevent accidents.
2) The storage area for ethylene oxide must be devoid of ignition sources, rotating motors, and exposure to direct sunlight. Ventilation should be excellent, with temperatures maintained below 40 ºC, while avoiding refrigeration. Strict adherence to national guidelines for storing flammable and explosive materials is essential.
3) Exercise caution when handling bottles to prevent spills or sprays of the hazardous liquid.
4) Conduct annual monitoring of ethylene oxide concentrations in the working environment to ensure occupational safety.
5) All personnel working with ethylene oxide must undergo specialized training in both routine handling and emergency response protocols.
Product formsHTAJ3 manual door cabinet
Power sourceAC380V,50Hz
Sterilizer size(Length × width × height): 2600×1400×1400mm
Sterilizer volume3 m³
Sterilizer interior material304 Anticorrosive stainless steel
Outer carton materialCarbon steel
Temperature during sterilization50ºC ±3ºC
Working pressure-60kpa
Maximum anti-stress value-150kpa
Humidity during sterilization45%-75%  
Pressure sensorThe built-in pressure sensor automatically detects the pressure inside the cavity to ensure that the pressure in the cavity is accurate and effective.
Ethylene oxide sterilization concentration1g/L Adjustable
Leakage rate of sterilization chamberThe leakage rate is measured under the conditions of no-load and constant temperature in the sterilization chamber, the test pressure is -50kPa, and the measurement time is 1h. The average leakage rate within the measurement time is ≤0.16kPa / min.
Sterilization time0-99 hours Adjustable
Vacuum speed15-25 minutes to -60kpa
Air replacementAutomatic ventilation, ventilation times and interval time can be set freely
Automatic control systemOne-key start to end, the whole process of automatic completion with printing records
Display statusDisplay temperature, humidity, pressure, sterilization time, residual gas treatment time, frequency

Printer
Record and print the sterilization information of the whole process for verification.
Humidity sensorThe built-in humidity sensor automatically detects the humidity in the cavity to ensure that the humidity in the cavity is not less than 45% RH.
Residual gas treatment deviceThe removal rate of the filter with a particle diameter ≥ 0.3 μm is not less than 99.5%.
Temperature sensorThe built-in temperature sensor automatically detects the temperature in the cavity to ensure that the temperature in the cavity is maintained within an accurate range of 50 ° C ± 3 ° C.
Humidification systemPulse humidification under vacuum to ensure that the humidity in the cavity is uniform and controllable; the humidity in the sterilization chamber should be controlled within the range of relative humidity 45% -80%;
alarm systemHigh temperature alarm system, ultra-low pressure alarm system; When the sterilization temperature of sterilization chamber exceeds 59ºC, the alarm shall be audible.
Vacuum rateUnder no-load condition, the time for the sterilization cabinet to vacuum from atmospheric pressure to -60kpa should be ≤30min.
Vacuum systemThe use of oil-free vacuum pump, simple and convenient, fast vacuum rate, long service life.
Multiple protection functionsWith over - pressure and over - temperature protection function, more safe and reliable.
Heating systemAdopt explosion-proof electric heating device, more convenient and fast

Technical characteristics

HTY series ethylene oxide sterilizer is purpose-built for low-temperature fumigation, achieving comprehensive sterilization within a controlled environment. The process involves precise regulation of temperature, pressure, humidity, and exposure time, using a blend of pure ethylene oxide, ensuring impeccable sterilization outcomes. ethylene oxide. Renowned for its potency, ethylene oxide gas is an exceptional chemical disinfectant. It offers broad-spectrum sterilization capabilities, delivering dependable and effective results with every use.
Advantages of ethylene oxide sterilizer
Effortless operation is at your fingertips with our ethylene oxide sterilizer. A single button initiates the process, managed by a microcomputer for ease and precision. The digital display provides real-time updates of the sterilization cycle, while a built-in printer records and prints detailed sterilization logs, offering easy verification and documentation. The sterilizer's air inlet features an advanced filtration system that effectively removes harmful microorganisms, preventing secondary contamination during air release.(1)Installation requirements of ethylene oxide sterilizer:
1) Position the ethylene oxide sterilizer in a spacious, well-ventilated area, distinctly separated from fire-prone zones.
2) Maintain a 51cm clearance around all sides and the top of the sterilizer to allow for unhindered access and maintenance.
3) Ensure the installation of dedicated exhaust pipes that are isolated from all other systems within the building to protect the integrity of the environment.
(2)Ethylene oxide safety protection principles and precautions:1) Position ethylene oxide sterilizers and containers prudently, ensuring they are distant from any ignition sources and static electricity. 2) Ethylene oxide storage must be devoid of ignition sources, free from rotating motors, shielded from sunlight, well-ventilated, and maintained at temperatures below 40 ºC, yet never placed in refrigerators. Adhere strictly to national regulations for managing flammable and explosive materials. 3) Handle bottles with care to prevent excessive force and avoid liquid spray. 4) Conduct annual monitoring of ethylene oxide air concentrations within the work environment. 5) Ensure staff handling ethylene oxide are expertly trained and equipped for emergency management.

company information
The Group is a beacon of innovation in the medical field, strategically gathering top-tier professionals and channeling robust technical expertise into research and development. Our significant investments have borne fruit, delivering groundbreaking advancements in ethylene oxide sterilizers. Through the integration of the cutting-edge 5G intelligent AI platform, we've revolutionized equipment operation, ensuring simplicity, safety, and superior sterilization performance that surpasses customer expectations. We uphold an unwavering commitment to high standards and responsibility in customer relations. Our corporate philosophy-prioritizing integrity before action-has fortified our position and propelled our growth within the medical device industry.

Our state-of-the-art equipment meets the rigorous standards of CE, ISO11135, and EN1422, ensuring versatility in sterilizing a vast array of products, including medical devices, healthcare facilities, plastic and disposable items, spices, traditional Chinese medicinal materials, cultural artifacts, and even currency. We invite you to reach out to us confidently for further information, as we are eager to assist you with your sterilization needs.

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA