FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation
When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.Advantages:







The control panel for an FM200 total flooding system is a critical component that monitors, controls,
and coordinates the various elements of the fire suppression system.
The components are as followings:

Agent:
Clean agent extinguishing systems fight fires using the chemical extinguishant Novec 1230 or with the chemical extinguishant HFC-227ea. This extinguishant is neither corrosive nor electrically conductive. It is thus especially suitable for protecting rooms containing electric and electronic equipment. The systems extinguish fires without leaving residue, while offering a high level of personal and environmental protection at the same time. They are particularly suitable for the protection of small and medium-sized rooms, and the extinguishing agent can be stored compactly, either inside the room or in another area.

Data Centers and Server Rooms:
Data centers house critical and sensitive electronic equipment, including servers and networking infrastructure. The FM200 system is well-suited for these environments as it provides rapid fire suppression without causing damage to the electronic components.
Telecommunication Facilities:
Facilities with communication equipment, such as telecommunication rooms and facilities housing switching equipment, benefit from the use of FM200 systems. The clean agent extinguishes fires without leaving residue that could harm sensitive telecommunications equipment.
Control Rooms:
Control rooms in various industries, such as manufacturing, energy, and transportation, often contain valuable and critical control systems. The FM200 system can protect these spaces without causing damage to control panels, displays, and other equipment.
Laboratories:
Research laboratories may house valuable and sensitive equipment, chemicals, and experiments. The FM200 system is suitable for protecting these environments without causing collateral damage to the equipment or experiments.
Museums and Archives:
Cultural institutions, museums, and archives may use FM200 systems to protect valuable artifacts, documents, and collections. The clean agent leaves no residue, reducing the risk of damage to delicate items.
Medical Facilities:
Certain medical facilities, such as imaging rooms and facilities with sensitive medical equipment, can benefit from FM200 fire protection. The system is non-corrosive and safe for use in environments with medical equipment.




PRI-SAFETY was established in 2004, is professional manufacturer of FM200 HFC227EA Fire Suppression System,
Automatic Fire Suppression System (For Kitchen. For Vehicle, For Electrical Devices),
CO2 Total Flooding Fire System,
Tube Automatic Fire Suppression System / Automatic Tube Fire Extinguisher,
CAFS Fire Systems (Compressed Air Foam Fire System),
Stainless Steel Fire Extinguisher,
Throwing Fire Extinguisher,
Cooking Oil Fire Extinguisher,Fire Extinguisher,etc.
Our products are mainly export to Europe, Middle east, America, South America, Africa, etc. Most of our products are with approval of CE, UN ECE R107, China CCC, UL, etc. We produce high quality fire fighting products, and we supply one-stop purchasing service too.