Medium Voltage Power Cable
Construction, Overhead, Industrial, Power Station, Telecommunication
Low and Medium Voltage Cable
DC & AC
XLPE
PVC/XLPE/PE/LSZH/CPE
Round Wire
Copper or Aluminum
ISO, CCC, CE, RoHS
YJLV22
Henway
High Quality
ASTM, BS, as, DIN, CSA, IEC, GB/T
1core or 3cores
Available
Yes
Henway
Wooden Drums, Steel-Wooden Drums, Steel Drums
Customized
China
7614900000
Product Description
5KV to 46KV Medium Voltage Cable
Application: Medium voltage power cables are apply for power transmission and distribution line at AC rated voltage up to 46kV.Applicable standards: IEC60502-2, BS6622, SANS1339, AS/NZS1429.1, DIN VDE 0276-626, NFC 33-226, IEC60840, ICEA S-93-639,ICEA S-94-649, HD620,CSA C68.10or the standards agreed by both of the customers and us.
Construction:
Conductor: IEC60228 class 1 class 2 bear copper/Aluminum etc
Conductor Screen: Semi-conducting compound
Insulation: XLPE or EPR
Insulation Screen: Semi-conducting compound
Core: 1core or 3cores
Shield: Copper wire/ Copper tape/AL plastic tape/Aluminum tape
Inner Sheath( optional): PVC PE LSZH CPE
Armoured ( optional): Galvanized steel wire/Aluminum wire/Two layers of Aluminum tapegap-wrapped /Two layers of steel tape gap-wrapped / Galvanized steel interlocked armour/Aluminum alloy interlocked armour
Outer Sheath: PVC PE LSZH CPE
3.6/6KV XLPE Insulated aluminum wire armour PVC sheath power cable | ||||||||||
Number of Cores and Nominal Area | Thickness of Insulation | Approx. Overall Diameter | Approx mass | Max. DC Resistance at 20ºC | Current Rating | |||||
Copper | Aluminium | |||||||||
Copper | Aluminium | Copper | Aluminium | Direct In Soil | In air | Direct In Soil | In air | |||
Nos×mm2 | mm | mm | kg/km | kg/km | Ohm/km | Ohm/km | A | A | A | A |
1×25 | 2.5 | 23.8 | 866 | 715 | 0.727 | 1.20 | 140 | 163 | 108 | 127 |
1×35 | 2.5 | 24.9 | 993 | 784 | 0.524 | 0.868 | 166 | 198 | 129 | 154 |
1×50 | 2.5 | 26.0 | 1152 | 867 | 0.387 | 0.641 | 196 | 238 | 152 | 184 |
1×70 | 2.5 | 27.7 | 1407 | 994 | 0.268 | 0.443 | 239 | 296 | 186 | 230 |
1×95 | 2.5 | 29.6 | 1721 | 1152 | 0.193 | 0.320 | 285 | 361 | 221 | 280 |
1×120 | 2.5 | 31.1 | 1994 | 1275 | 0.153 | 0.253 | 323 | 417 | 252 | 324 |
1×150 | 2.5 | 32.7 | 2301 | 1425 | 0.124 | 0.206 | 361 | 473 | 281 | 368 |
1×185 | 2.5 | 35.4 | 2804 | 1696 | 0.0991 | 0.164 | 406 | 543 | 317 | 424 |
1×240 | 2.6 | 38.0 | 3430 | 1976 | 0.0754 | 0.125 | 469 | 641 | 367 | 502 |
1×300 | 2.8 | 40.8 | 4119 | 2294 | 0.0601 | 0.100 | 526 | 735 | 414 | 577 |
1×400 | 3.0 | 44.4 | 5043 | 2706 | 0.0470 | 0.0778 | 590 | 845 | 470 | 673 |
1×500 | 3.2 | 49.8 | 6393 | 3398 | 0.0366 | 0.0605 | 735 | 958 | 578 | 767 |
1×630 | 3.2 | 53.9 | 7892 | 4024 | 0.0283 | 0.0469 | 831 | 1098 | 665 | 896 |
1×800 | 3.2 | 58.2 | 9719 | 4757 | 0.0221 | 0.0367 | 945 | 1266 | 761 | 1041 |
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ; Thermal resistivity of soil 1,5 K.m/W | ||||||||||
3.6/6KV XLPE Insulated steel wire armour PVC sheath power cable | ||||||||||
Number of Cores and Nominal Area | Nominal Thickness of Insulation | Approx. Overall Diameter | Approx mass | Max. DC Resistance at 20ºC | Current Rating | |||||
Copper | Aluminium | |||||||||
Copper | Aluminium | Copper | Aluminium | Direct In Soil | In air | Direct In Soil | In air | |||
Nos×mm2 | mm | mm | kg/km | kg/km | Ohm/km | Ohm/km | A | A | A | A |
3×25 | 2.5 | 41.9 | 3207 | 2748 | 0.727 | 1.20 | 129 | 143 | 100 | 111 |
3×35 | 2.5 | 45.6 | 4054 | 3430 | 0.524 | 0.868 | 154 | 172 | 119 | 133 |
3×50 | 2.5 | 48.2 | 4654 | 3792 | 0.387 | 0.641 | 181 | 205 | 140 | 159 |
3×70 | 2.5 | 52.2 | 5592 | 4347 | 0.268 | 0.443 | 220 | 253 | 171 | 196 |
3×95 | 2.5 | 56.1 | 6703 | 4975 | 0.193 | 0.320 | 263 | 307 | 204 | 238 |
3×120 | 2.5 | 60.0 | 7762 | 5582 | 0.153 | 0.253 | 298 | 352 | 232 | 274 |
3×150 | 2.5 | 63.4 | 8878 | 6187 | 0.124 | 0.206 | 332 | 397 | 259 | 309 |
3×185 | 2.5 | 67.3 | 10248 | 6881 | 0.0991 | 0.164 | 374 | 453 | 293 | 354 |
3×240 | 2.6 | 73.5 | 12509 | 8072 | 0.0754 | 0.125 | 431 | 529 | 338 | 415 |
3×300 | 2.8 | 81.0 | 15741 | 10190 | 0.0601 | 0.100 | 482 | 599 | 380 | 472 |
3×400 | 3.0 | 88.8 | 19093 | 11996 | 0.0470 | 0.0778 | 541 | 683 | 432 | 545 |
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ; Thermal resistivity of soil 1,5 K.m/W | ||||||||||
18/30KV XLPE Insulated aluminum wire armour PVC sheath power cable | ||||||||||
Number of Cores and Nominal Area | Thickness of Insulation | Approx. Overall Diameter | Approx mass | Max. DC Resistance at 20ºC | Current Rating | |||||
Copper | Aluminium | |||||||||
Copper | Aluminium | Copper | Aluminium | Direct In Soil | In air | Direct In Soil | In air | |||
Nos×mm2 | mm | mm | kg/km | kg/km | Ohm/km | Ohm/km | A | A | A | A |
1×35 | 8.0 | 37.4 | 1840 | 1630 | 0.524 | 0.868 | 170 | 201 | 132 | 158 |
1×50 | 8.0 | 38.7 | 2036 | 1751 | 0.387 | 0.641 | 200 | 242 | 156 | 190 |
1×70 | 8.0 | 40.4 | 2335 | 1920 | 0.268 | 0.443 | 242 | 300 | 190 | 235 |
1×95 | 8.0 | 42.3 | 2681 | 2112 | 0.193 | 0.320 | 288 | 363 | 224 | 285 |
1×120 | 8.0 | 43.8 | 2996 | 2278 | 0.153 | 0.253 | 326 | 420 | 256 | 328 |
1×150 | 8.0 | 46.4 | 3506 | 2621 | 0.124 | 0.206 | 364 | 476 | 286 | 372 |
1×185 | 8.0 | 48.3 | 3970 | 2862 | 0.0991 | 0.164 | 409 | 546 | 321 | 428 |
1×240 | 8.0 | 50.9 | 4661 | 3207 | 0.0754 | 0.125 | 472 | 645 | 372 | 505 |
1×300 | 8.0 | 53.5 | 5380 | 3555 | 0.0601 | 0.100 | 529 | 740 | 418 | 578 |
1×400 | 8.0 | 56.7 | 6333 | 3996 | 0.0470 | 0.0778 | 593 | 848 | 475 | 675 |
1×500 | 8.0 | 60.5 | 7556 | 4561 | 0.0366 | 0.0605 | 740 | 963 | 583 | 772 |
1×630 | 8.0 | 64.8 | 9172 | 5304 | 0.0283 | 0.0469 | 835 | 1101 | 675 | 900 |
1×800 | 8.0 | 69.1 | 11063 | 6101 | 0.0221 | 0.0367 | 950 | 1272 | 765 | 1046 |
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ; Thermal resistivity of soil 1,5 K.m/W | ||||||||||
18/30KV XLPE Insulated steel wire armour PVC sheath power cable | ||||||||||
Number of Cores and Nominal Area | Thickness of Insulation | Approx. Overall Diameter | Approx mass | Max. DC Resistance at 20ºC | Current Rating | |||||
Copper | Aluminium | |||||||||
Copper | Aluminium | Copper | Aluminium | Direct In Soil | In air | Direct In Soil | In air | |||
Nos×mm2 | mm | mm | kg/km | kg/km | Ohm/km | Ohm/km | A | A | A | A |
3×35 | 8.0 | 72.1 | 7473 | 6848 | 0.524 | 0.868 | 154 | 175 | 118 | 132 |
3×50 | 8.0 | 76.2 | 9011 | 8149 | 0.387 | 0.641 | 180 | 210 | 139 | 158 |
3×70 | 8.0 | 80.3 | 10196 | 8951 | 0.268 | 0.443 | 217 | 258 | 171 | 200 |
3×95 | 8.0 | 84.4 | 11479 | 9751 | 0.193 | 0.320 | 261 | 310 | 204 | 240 |
3×120 | 8.0 | 88.0 | 12743 | 10563 | 0.153 | 0.253 | 296 | 353 | 229 | 279 |
3×150 | 8.0 | 91.2 | 13918 | 11228 | 0.124 | 0.206 | 332 | 405 | 256 | 310 |
3×185 | 8.0 | 95.3 | 15562 | 12196 | 0.0991 | 0.164 | 374 | 458 | 293 | 360 |
3×240 | 8.0 | 101.1 | 18038 | 13601 | 0.0754 | 0.125 | 429 | 535 | 338 | 420 |
3×300 | 8.0 | 106.2 | 20502 | 14952 | 0.0601 | 0.100 | 482 | 602 | 380 | 474 |
3×400 | 8.0 | 113.0 | 23898 | 16800 | 0.0470 | 0.0778 | 541 | 690 | 428 | 545 |
Trefoil arrangement;Maximum conductor temperature 90 °C ;Ambient air temperature 30 °C ;Ground temperature 20 °C ;Depth of laying 0,8 m ; Thermal resistivity of soil 1,5 K.m/W |

* We can design and produce according to client's requirement. Any requirement, feel free to contact us!
For more information about wires and cables, please feel free to contact us. Your inquiries will be replied to within 1 hours!!

industry. It covers an area of 210,000 square meters and has more than 2,000 employees. It has successively introduced about 2,000 items of
advanced R&D, production and testing equipment. The annual production capacity exceeds 30 billion yuan.
Henway's products can be divided into four categories,namely power cable, wire &cable for electrical equipment, communication cable and
building wire.They include insulated power cable of 220KV and below, Rubber insulated cable of 35KV and below, Aerial insulated cable,Overhead
conductor,Mining cable etc,a total of nearly 30 product series with nearly 4,000 types and 50,000 items.The products are widely used in the fields of infrastructure, utility, hydro-water projects, iron, mining, petroleum, chemical industry,building,subway, high-speed rail,airports,etc.
They have been exported to more than 100 countries around the world.
Henway passed ISO 9001,ISO 14001,OHSAS 18001,and successively acquired TUV certificate,CE certificate,UL certificate and so on.More than 30 years of development and cultivation makes the extraordinary achievements of Henway.Henway is still promoting the enterprise's scale,technology
and brand construction.
Heway Cable-make pioneering efforts and forge ahead !

1. Q:How does your factory control the quality?
2. Q:Can I visit your company?
A: Sure,If you need,we will arrange the driver to pick you up.
3. Q:How can I get some samples?
A: Contact me on below,Determin sample and address for shipping.
4. Q:Have you ever supplied cables to our country?
A: Henway Cables have been sold to over 100 countries and regions in the world. you can contact me for details.
5. Q:What is your MOQ?
A: MOQ Normally 500 meters for big diameter cables. Please contact me for detail info if you have specific cable requirement.
6. Q:When can I get the price?
A: Usually quote within 6 hours after we get your inquiry.
7. Q:How long is your delivery time?
A: According to your order's quantity. Usually our lead time is 3 - 20 working days.