It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90°C. In short circuit, conductor highest temperature should be not more than 250°C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90°C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250°C.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0°C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Type | Description | Number of cores | Nominal cross section of conductor |
YJV32 | CU/XLPE/SWA/PVC Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 | 1.5~1000mm2 |
YJLV32 | AL/XLPE/SWA/PVC Power Cable | ||
YJV72 | CU/XLPE/Non-magnetic SWA or AWA/PVC Power Cable | 1 | 1.5~1000mm2 |
YJLV72 | AL/XLPE/Non-magnetic SWA or AWA/PVC Power Cable | ||
YJV33 | CU/XLPE/SWA/PE Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 | 1.5~1000mm2 |
YJLV33 | AL/XLPE/SWA/PE Power Cable | ||
Z-YJV32 | CU/XLPE/SWA Flame-retardant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 | 1.5~1000mm2 |
Z-YJLV32 | AL/XLPE/SWA Flame-retardant Power Cable | ||
WDZ-YJY33 | CU/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 | 1.5~1000mm2 |
WDZ-YJLY33 | AL/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable | ||
N-YJV32 | CU/XLPE/SWA Fire-resistant Power Cable | 1, 2, 3, 4, 3+1, 5, 4+1, 3+2 | 1.5~1000mm2 |
Type | Name | Application | |
Cu conducto | Al Conductor | ||
YJV | YJLV | XLPE insulated, PVC or PE sheathed power cable | For laying indoor, tunnel, channel and underground. Unable to bear external mechanical force during laid. |
YJY | YJLV | ||
YJV22 | YJLV22 | XLPE insulated, steel tape armoured, PVC or PE sheathed power cable | For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
YJV23 | YJLY23 | ||
YJV32 | YJLV32 | XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable | For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
YJV42 | YJLV42 | XLPE insulated, thick steel armoured, PVC or PE sheathed power cable | For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |






1) Packing length:100 to 1,000m reeled in carton drum or according to customers' requirement
2) Outer packing: wooden case, carton box
3) Other packing requirement according to client's request
1. Who are we?
We are based in Henan, China, start from 2001,sell to Southeast Asia(39.00%),North America(20.00%),South America(15.00%),Mid East(15.00%),Africa(10.00%),Domestic Market(1.00%). There are total about 11-50 people in our office.
2. How can we guarantee quality?
Always a pre-production sample before mass production; Always final Inspection before shipment.
3.What can you buy from us?
Electric wire cable,Power cable.
4. why should you buy from us not from other suppliers?
Jinshui Wire & Cable Group is also a key company of high and new technology. We have more than 20years export experience and know most of standards well. we can produce more than 1,400 types of cables and wires in scores of categories.
5. what services can we provide?
Accepted Delivery Terms: FOB,CIF;
Accepted Payment Currency:USD,EUR,HKD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,Credit Card;
Language Spoken:English,Chinese,Spanish
Thank you for your inquiry!!!!!!