DC Surge Protection Device 1000V 40ka SPD for Solar System

Price $13.00 Compare
Min Order 50 Pieces
Shipping From Zhejiang, China
Popularity 210 people viewed
Quantity
+-
 

Wenzhou Leeyee Electric Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
LY1-C40/3S PV
15.4kgs
20ka(8/20us)
40ka(8/20us)
6.25ka(10/350us)
3.6ka
Yes
FedEx, DHL, UPS, Aramex,EMS
3-5 Days
LEEYEE
50PCS/CTN
41x22x31cm
China
8536300000
Product Description
Product Description
Application
This T1+T2 DC spd surge protective device is applied low voltage standard IEC EN 61643-33 to protect against DC power line system and other equipment from over voltage and instantaneous over voltage damage. Widely used in photovoltaic comber box, power inverter, DC distribution cabinet etc. It has advantages of large discharge current, fast respond time, low residual voltage.The max. PV voltage up to UCPV ≤1500V dc.
 
Features
1. Prewired complete unit consisting of a base part and plug-in protection modules
2. High discharge capacity due to heavy duty zinc oxide varistors
3. High reliability due to 'temperature-controlled' SPD monitoring device
4 .Din rail installation, easy to install.
5. Inside over-current, over-heat, temperature control open circuit.
6. Fast response time, low residual voltage.
7. Window color indicates working condition, green means normal, red means fault.
8. Class I II T1+2 protection degree.
 
Installation position
The cross-sectional area of ground wire should not be less than 4 mm2, and the length of total lead not more than 0.5m.
0.5MM
 
The minimum distance from any earthed conductive surface at which the SPD can be installed is 8mm.
 
Connection of remote signalling alarm: the SPD is provided with remote signalling interfaces (NC, COM and NO, normally closed), applicable for remote centralized monitoring or alarm. After the connection, check if the module is fitted in. If so, NC and COM are closed; if not, repress the module.
Model
LY1-C40PV
SPD according to EN 61643-11 / IEC 61643-11
Type 1+2 / class I+II
Max. continuous operating pv. voltage Uc
1000V DC 
Nominal discharge current (8/20μs) In
20kA
Maximum discharge current (8/20μs) Imax
40kA
Maximum impulse current (10/350μs) Iimp
6.25 kA
Impulse current totally (10/350μs) Iimp
12.5kA
Voltage protection level Up
3.6 kV 
Follow current extinguishing capability [N-PE] Ifi
100Arms
Response time tA
25ns (L-N)
Matched fuse or circuit breaker
32A
Operating state / fault indication
Green ok / Red defect
Cross-sectional area (min.)
1.5 mm2 solid /flexible
Cross-sectional area (max.)
35 mm2 stranded / 25 mm2 flexible
For mounting on
35 mm DIN rail acc. to EN 60715
Switching capacity
AC:250V/0.5A DC:250V/0.1A,125V/0.2A,75V/0.5A
Remote signalling alarming mode
Normal: closed; Failure: open-circuit