SRPM210L8F132
Universal, Industrial, Power Tools, Fan, Blower, Mining, Compressor, Pump
High Speed
Electric Motor
Permanent Magnet
Driving
Rotating Armature Type (Pole Fixed)
8
Open Type
ISO9001, CE, RoHS
Mc-Motor
6000rpm 7000rpm
Air Cooling, Water Cooling, Oil Cooling
80kw - 160kw
5000rpm, 6000rpm, 7000rpm
H
IP54
Im B35
S1-S9
Compressor, Blower, Fan, Test Bench
110kw 132kw
mc motor
1PC/ Carton ( Wood /Paper Box Optional)
TBD (based on real motor dimension)
China
8501520000
Product Description
Synchronous High Speed PMS Electric Motor 110kw 132kw 7000rpm IEC European Standard

Product Feature
1.Suitable for the 6000-7000rpm Rated Speed
2.Reserve a large margin of security
3.Low power & low torque
4.High efficiency 96.5%
5.Small size
6.Low noise low vibration
7.The autonomous patented cooling structure
Specifications
Model type:SRPM290L8F132
Voltage: 380-400V AC
Rated Power:75kw,87kw,110kw,132kw
Rated Speed:6000rpm,7000rpm
Isolation: H/F
Cooling Method:Air/Water (glycol)/ Oil
Ingress Protection:IP54(IP67 option)
Duty type: S1
Pole:8
Rated Torque: 180N.m
NW: 180KG


Company Introduction


Power: 5KW-2MW
Speed:2500rpm-100000rpm
Voltage:110v-690v






Other motors you will be interested in
FAQ
1. Can performanent magnet synchronous motor be used as generator?
Yes. Permanent magnet synchronous motor can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation.


Product Feature
1.Suitable for the 6000-7000rpm Rated Speed
2.Reserve a large margin of security
3.Low power & low torque
4.High efficiency 96.5%
5.Small size
6.Low noise low vibration
7.The autonomous patented cooling structure
Specifications
Model type:SRPM290L8F132
Voltage: 380-400V AC
Rated Power:75kw,87kw,110kw,132kw
Rated Speed:6000rpm,7000rpm
Isolation: H/F
Cooling Method:Air/Water (glycol)/ Oil
Ingress Protection:IP54(IP67 option)
Duty type: S1
Pole:8
Rated Torque: 180N.m
NW: 180KG


Company Introduction
MC MOTOR is a high-tech manufacturing enterprise which focuses on special permanent magnet motor. MC MOTOR globally leads high-speed motor technology with the strongest R&D capability obtained more than 100 intellectual property patents. Our products are applied to high-speed compressor, fan, turbine, pump, supercharger and new energy fuel cell compressor system in vehicles, and other new emerging industries. New designs are more than 50 types from 8kw to 200kw, between 5000rpm and 24000rpm. Besides, product quality is guaranteed because all production process strictly abide by ISO9001-2015.


Main Service
We can provide customers with customized services, according to your motor application scenarios and needs, so that you can apply rationally and save costs.

Customizing Range:
Power: 5KW-2MWSpeed:2500rpm-100000rpm
Voltage:110v-690v







Motor type | Voltage | Rated power | Rated torque (N.m) | Rated speed | Efficiency | Insulation | Ingress protection | Pole Number | PIC | Weight | Cooling Method | Position Signal | Duty Type | Installation Method |
(V AC) | (kW) | (rpm) | (%) | (kg) | ||||||||||
SPRM( General) | 380 | 5.5-110 | 10-420 | 10000-80000 | 95.00% | H/F | IP54/IP67 | 8 | 19-112 | Water | Resolver | S1-S9 | B35 | |
SPRM( General) | 380 | 4-37 | 35-463 | 15000-24000 | 95.00% | H/F | IP54/IP67 | 8 | 14-100 | Air | N/A | S1-S9 | B35 | |
SPRM( General) | 380 | 37-350 | 35-463 | 12000-24000 | 95.00% | H/F | IP54/IP67 | 8 | 14-25 | Oil | N/A | S1-S9 | B35 | |
SRPM112H4F7.5C | 380 | 7.5 | 3.4 | 21000 | 95 | H/F | IP54 | 4 | 12 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F7.5C | 380 | 7.5 | 3 | 24000 | 95 | H/F | IP54 | 4 | 12 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F15F | 380 | 15 | 6 | 24000 | 95 | H/F | IP54 | 4 | 20 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F18.5 | 380 | 18.5 | 8.41 | 21000 | 95 | H/F | IP54 | 4 | 25 | Air | N/A | S1-S9 | B35 | |
SRPM180L8F18.5 | 380 | 18.5 | 33.3 | 5300 | 95 | H/F | IP54 | 8 | 25 | Air | N/A | S1-S9 | B35 | |
SRPM130H4F22 | 380 | 22 | 10 | 21000 | 95 | H/F | IP54 | 4 | 33 | Air | N/A | S1-S9 | B35 | |
SRPM130H4F37 | 380 | 37 | 19.63 | 18000 | 95 | H/F | IP54 | 4 | 47 | Air | N/A | S1-S9 | B35 | |
SRPM168H2F75C | 380 | 75 | 21.07 | 34000 | 95 | H/F | IP54 | 2 | 50 | Air | N/A | S1-S9 | B35 | |
SRPM112H4F15 | 380 | 15 | 5.96 | 24000 | 96.5 | H/F | IP54 | 4 | 12 | Air/Water | N/A | S1-S9 | B35 | |
SRPM112H4W5.5 | 380 | 10 | 2.5 | 21000 | 94 | H/F | IP67 | 4 | 14 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W10 | 380 | 10 | 8 | 12000 | 94 | H/F | IP67 | 4 | 20 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W20 | 380 | 20 | 8 | 24000 | 96.5 | H/F | IP54 | 4 | 25 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W22B | 380 | 22 | 8.75 | 24000 | 96.5 | H/F | IP54 | 4 | 25 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W25 | 380 | 25 | 15.9 | 15000 | 96.5 | H/F | IP54 | 4 | 28 | Water | N/A | S1-S9 | B35 | |
SRPM112H4W30 | 380 | 30 | 17.9 | 16000 | 96.5 | H/F | IP54 | 4 | 32 | Water | N/A | S1-S9 | B35 | |
SRPM210M4W55B | 380 | 55 | 52.5 | 10000 | 95.4 | H/F | IP54 | 4 | 55 | Water | N/A | S1-S9 | B35 | |
SRPM210H4W60 | 380 | 60 | 45.8 | 12500 | 96.5 | H/F | IP54 | 4 | 80 | Water | N/A | S1-S9 | B35 | |
SRPM210M4W75C | 380 | 75 | 71.6 | 10000 | 96.5 | H/F | IP54 | 4 | 95 | Water | N/A | S1-S9 | B35,V1 | |
SRPM130H4W20 | 380 | 20 | 3.3 | 60000 | 95.00% | H/F | IP54/IP67 | 4 | 45 | Water | N/A | S1-S9 | B35 | |
SRPM95H2W18 | 380 | 18 | 0.667 | 75000 | 95.00% | H/F | IP54/IP67 | 2 | 45 | Water | N/A | S1-S9 | B35 | |
SRPM95H2W5.5 | 380 | 5.5 | 2.29 | 80000 | 95.00% | H/F | IP54/IP67 | 2 | 25 | Water | N/A | S1-S9 | B35 | |
SRPM180M8O30 | 380 | 30 | 23.8 | 12000 | 96.5 | H/F | IP67 | 8 | 12 | Water/Oil | N/A | S1-S9 | B35 | |
SRPM165H4XO37 | 380 | 37 | 17.7 | 20000 | 96.50% | H/F | IP54/IP67 | 4 | 100 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O50 | 380 | 50 | 19.9 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 100 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O75 | 380 | 75 | 29.8 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 120 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O100 | 380 | 100 | 39.8 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 150 | Oil | N/A | S1-S9 | B35 | |
SRPM214H4O124 | 380 | 124 | 66 | 18000 | 95.00% | H/F | IP54/IP67 | 4 | 250 | Oil | N/A | S1-S9 | B35 | |
SRPM160H4XO90 | 380 | 90 | 43 | 20000 | 96.5 | H/F | IP67 | 4 | 48 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4XO110 | 380 | 110 | 52.5 | 20000 | 96.5 | H/F | IP67 | 4 | 76 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4XO160 | 380 | 160 | 76.4 | 20000 | 96.5 | H/F | IP67 | 4 | 86 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4XO200 | 380 | 200 | 95.5 | 15500 | 95.5 | H/F | IP67 | 4 | 350 | Oil | N/A | S1-S9 | B35 | |
SRPM205H4O220 | 380 | 200 | 131.1 | 16000 | 95.5 | H/F | IP67 | 4 | 310 | Oil | N/A | S1-S9 | B35 | |
SRPM290H4O350 | 380 | 350 | 167.1 | 20000 | 95.5 | H/F | IP67 | 4 | 530 | Oil | N/A | S1-S9 | B35 |
Motor type | Voltage (V AC) | Rated power (kW) | Rated torque (N.m) | Rated speed (rpm) | Efficiency (%) | Duty type | Insulation | Ingress protection | Pole Number | Weight (kg) | Cooling Method | position signal |
SRPM160H4XO15 | 380 | 15 | 5.96 | 24000 | 96.5 | S1 | H/F | IP67 | 4 | 12 | Oil | Resolver |
SRPM160H4XO75 | 380 | 75 | 35.8 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 44 | Oil | Resolver |
SRPM160H4XO90 | 380 | 90 | 43 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 48 | Oil | Resolver |
SRPM205H4XO110 | 380 | 110 | 52.5 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 76 | Oil | Resolver |
SRPM205H4XO160 | 380 | 160 | 76.4 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 86 | Oil | Resolver |
SRPM205H4XO200 | 380 | 200 | 95.5 | 20000 | 96.5 | S1 | H/F | IP67 | 4 | 95 | Oil | Resolver |
FAQ
1. Can performanent magnet synchronous motor be used as generator?
Yes. Permanent magnet synchronous motor can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation.