Product Description
Containerized Resistive/Reactive Load Bank 1250KVA, 400V, PF 0.8
The 1250KVA 400V containerized resistive/reactive load bank is a robust and reliable testing solution designed for continuous operation over extended periods. It features the following key characteristics:

Power Rating:
Total Capacity: 1250KVA
Voltage: 400V
Power Factor: 0.8

Construction:
Enclosed in a durable, weatherproof ISO container for safe outdoor and indoor operations.
Compact and transportable, suitable for easy deployment in various locations.
Cooling System:
Equipped with a high-volume industrial blower system that ensures efficient cooling of resistors and internal components.
Designed to maintain optimal operating temperatures, enabling continuous operation for up to 48 hours without requiring shutdown for cooldown.
Performance:

Incorporates high-quality resistive and reactive elements to simulate real-world load conditions accurately.
Supports testing of generators, UPS systems, and other power equipment with stable and reliable performance.
Control Options:
Remote and local control capabilities for flexible operation.
Intuitive control interface for precise load adjustment and real-time monitoring.
Safety Features:
Overload protection, over-temperature alarms, and emergency stop buttons ensure safe operation.
Compliance with international safety standards.
This load bank is an ideal choice for applications requiring high-performance and continuous-duty testing, such as in shipyards, data centers, power plants, and renewable energy facilities. It delivers reliable results, ensuring your power systems operate at peak efficiency under load conditions.
Description
Model No.S1250L
Country of originChina
Apparent power capacity(kV.A)1250 
Active power capacity(kW PF: 0.8)1000
Active power step load(kW)5+5+10+10+20+50+100*5+200*2
Reactive power capacity(kVAR)750
Reactive power step load(kVAR)5+5+10+10+20+50+50+150*4
Rated testing voltage480 Vac
Frequency60Hz.
Phases3
Wires(Delta connection)3
Load step resolution5kW  5kVAR
Voltage Tolerance (Short Term Operation)+5%
Load Element Tolerance± 2.5%
Insulation Test600 Vac
Load ConnectionsCopper busbars

Protection
Thermal emergency cut out
Air flow switch
Fan overload protection
Emergency stop
Control voltage(Auxiliary power supply)Optional 380V/ 400V/415V   50/60HZ.
Airflow volume(Approx. CMM)1600 CM/Min.
Airflow directionAir forced cooling,side air inlet and vertical outlet 
Load switching contactor type3 pole AC contactors
Rated maximum ambient temp. operation+60°C
Rated minimum ambient temp. operation-25°C
PortabilityFolklift holes &ISO standard lifting holes
Color RAL 7035(Customizable)
Enclosure dimentions
Length(mm)3000
Width(mm)2000
Height(mm)2591
Weight(KG) 3,900