Wholesale Price AC 220V/380V 1/3 Phase Power Frequency Converter 0.75/1.5/15/160kw

Price Negotiable Compare
Min Order 1 PCS
Shipping From Guangdong, China
Popularity 316 people viewed
Quantity
+-
 

SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO., LTD

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
ENA100 Series
Three Phase Transducer, General Transducer, Single-phase Transducer
Triple
V/F Control Transducer
PWM Control
Voltage
Low Voltage Variable-Frequency Drive
AC-DC-AC Variable-Frequency Drive
Simple Type, Textile Special, Constant Torque Universal Type
Enc
ENC
Carton/Wood
Shenzhen, China
8504409999
Product Description
Product Description

Product Description:
ENA100 is a cost-effective general vector inverter with a power range from 0.4kW to 160kW. Built-in macro functions for typical industry applications, greatly facilitate customer operations. Models below 30KW are equipped with a built-in braking unit as standard. Suitable for higher ambient temperature situations. 


Typical application industry:
It is suitable for metal processing, plastic machinery, CNC machine tools, printing equipment, printing and dyeing industry, paper making, municipal engineering, water supply engineering, sewage treatment, etc. lt is also widely used in textile,refrigeration, cement, ceramics, stone processing and other fields.

Product advantages:
  1. Covering sensorless magnetic flux vector control and optimized V/F control, with two modes of speed control and torque control;
  2. Adopting excellent magnetic flux vector control algorithm, high control precision, fast speed response, and excellent low-frequency characteristics, +0.3% rated synchronous speed (vector control without PG); +1% rated synchronous speed (V/F control)
  3. Excellent application macro function, can drive synchronous and asynchronous motors, strong environmental adaptability 50°C without derating, support dual keyboard display, local and remote control keyboards can be used at the same time, small size, high cost performance
  4. Power-on short circuit detection, input and output phase loss protection, over-current protection,under-voltage protection, overheat protection, overload protection, under-load protection, terminal protection, power failure non-stop protection, PlD disconnection protection, water shortage protection.etc.
  5. Support random carrier function, the motor noise is softer
  6. No derating required for 50°C ambient temperature in heavy duty mode
 
 

ENA100 Performance advantage:
Two-in-one drive
Motor type: can drive both synchronous and asynchronous motors;
One-key switch between synchronous motor and asynchronous motor, convenient for debugging;
Convenient stocking, effectively shorten the cycle of the warehouse;
ENA100 supports both synchronous and asynchronous motors.



Dynamic response:
Torque response:<20ms (without PG quantity control)
Starting torque:1.0Hz, 150% rated torque (V/F control)0.5Hz up to 180% torque (No PG open loop vector)
Control accuracy:±1% rated synchronous speed (V/F control)+0.3% rated synchronous speed (No PG quantity control)



Convenient and practical keyboard:
Support dual keyboard display
Support the simultaneous use of local keyboard and external control keyboard
External control keyboard can realize parameter upload and download function
The local keyboard and external control keyboard of traditional inverter can only one to use.
ENA100 local and external control keyboard can be used simultaneously


Application macro function:
Built-in multiple application macros, only need to set one parameter for different industries.




Structural optimization design:
The difference of power section:
Conventional general series power section :0.4KW~55KW
ENA100 series power section:0.4KW~160KW


Brake unit:
Conventional general series:Three-phase 380V,0.75KW~15KW with built-in brake unit
Three-phase 380V,18.5KW~55KW, optional built- in brake unit

ENA100 series:
Single-phase 220V,0.4KW~2.2KW with built-in brake unit
Three-phase 380V,0.75KW~22KW with built-in brake unit
Three-phase 380V,30KW~160KW, optional external brake unit

No derating at 50ºC and below:
Passed many rigorous tests: salt spray test, high and low temperature impact test, vibration test, ete.
Normal inverter is 30°C, national standard temperature is 40°C, ENA 100 is 50ºC




 
Product Specification
 Product Specification
 
ItemDescription


Input

 
Rating volt, frequency1 phase 220VGrade:1 phase 220V50Hz/60Hz
3 phase380VGrade: 3 phase380V50Hz/60Hz
Allow volt.range1 phase 220VGrade: 200~260V
3 phase 380VGrade: 320~460V
OutputVoltage0~Input voltage
Frequency0~600HZ
Over loading capacityHeayy Load:150% of rated current for l minute:Light Load:120% of rated current for 1 minute.
Control 
PerformaAnalog input channelnce
Control modeWithout PG vector control, open loop V/F control.
Without PG torque control, support synchronous and asynchronous motors
Velocity control precision+0.3% rated synchronous speed(vector control);
+1% rated synchronous speed(V/F control);
Speed regulation range1:100(Without PG vector control)
1:50(V/F control)
Start-up torque1.0Hz: 150% rated torque (V/F control);
0.5Hz:150% rated torque (Without PG vector control);
Speed fluctuation+0.3% rated synchronous speed (Without PG vector control, Without PG torque control); (Without PG vector control)
Torque response≤20ms(Without PG vector control)
Frequency precisionDigital setting: max.Frequency×±0.01%; Analog setting:max.frequency×±0.5%
Frequency
resolution
Analog setting0.1% of max.frequency
 
Digital setting precision0.01Hz
Exterior impulse0.1% of max.frequency
Torque boostAutomatic torque boost;manual torque boost 0.1~12.0%
V/F curve(volt. Frequency
characteristic)
Setting rated frequency at the range of 5~600Hz, by choosing constanttorque, degressive torque l, degressive torque 2, degressive torque3, self-defined V/F total 5 kinds of curve.
Acceleration Deceleration curveTwo methods: linear acceleration and deceleration and S curve accelerationand deceleration; 15 kinds of acceleration and deceleration time, time unit(0.01s.0.1s.1s)
BrakePower consumption brakeENA100 series three-phase 22KW and below power section has built-in braking unit, only need to add braking resistor between (+)and PB; 30KW and above can connectexternal braking unit between (+) and (-)to achieve Energy consumption braking.
DC brakeStart, stop action for option, action frequency 0~15Hz, action current 0~100% of ratedcurrent, action time 0~30.0s
JogJog frequency range:0Hz~up limit frequency ; jog acceleration and deceleration time
0.1~6000.0 seconds for setting.
Multi-section speed runRealized by inbuilt PLC or control terminal; with 15 section speed, each section speed with separately acceleration and deceleration time; with inbuilt PLC can achieve reserve when power down.
Built-in PID controllerConvenient to make closed-loop control system
Automatic energy saving runOptimize V/F curve automatically to achieve power saving run according to the load status.
 

Control performance
 
Automatic voltage regulate(AVR)Automatically keep output voltage constant, when the power grid voltage fluctuation
Automatic current limitingCurrent limited automatically under run mode in avoid of inverter over-current frequently to trip
Carrier modulationMake rotating motor smoothly start without shocking
Speed tracking restartMake rotating motor smoothly start without shocking
Running functionRunning command specifed channelKeypad specified, control terminal specifed, communication specifed can switch through various means
Running frequency specified channelMain & auxiliary specifed to a realize one main adjusting and one fine control. Digital specifed, analog specified, pulse specifed, pulse width specifed, communication specifed and others, which can be switched by many means at any time.
Binding functionRun command channel and frequency specified channel can bind together randomly and switch synchronously
Input and output characteristicsDigital input channel5 general-purpose digital input channels, the maximum frequency is lKHz, one of which can be used as a pulse input channel, the maximum input is 20KHz
Analog input channel2 analog input channels, of which All is 0~10V output, AI2 channel is 0~20mA or 0~10V input optional.
Pulse output channel0.1 ~20KHz pulse square signal output to achieve setting frequency, output frequency andother physical quantity output.
Analog output channel1 analog signal output, AOl channel can choose 0~20mA or 0~10V to realize the output of physical quantities such as set frequency and output frequency
Digital output2 Y outputs, Y2 can achieve the highest frequency output of 20K, 1 Rel output
Unique functionRapid current limitLimit inverter over current to the greatest point, and make it run more stably
Monopulse controlSuitable for working site where need one button to control inverter start and stop,first press to start, then press to stop, and that cycle repeats. Its very simple and reliable.
Fixed length controlRealize fxed length control
Timing controlTiming control function: setting time range 0.1Min~6500.0 Min
Virtual terminalFive group virtual input & output lO can realize simply logical control
Operation keyboardKeyboard displayThe parameters as setting frequency, output frequency, output voltage, output current canbe displayed
Button lockedLock all or part ofthe buttons
Dual keyboard controlCan use external keyboard to achieve dual keyboard control (local and remote control)
Dual keyboard controlMotor power on Shot circuit test, input & output phase loss protection, over-currentprotection, over voltage protection, under voltage protection, over heat protection,overload protection, under load protection, relay absorption protection, terminalprotection and no stop protection under power of.
AmbientApplication siteIndoor, not bare to sunlight, no dust, no corrosive gas, no flammable gas, no vapor, nowater drop or salt etc.
AltitudeUnder 1000 meter. (above 1000 meter require to reduce volume to use, output currentreduce about 10% of rated current volt per 1000 meter high)
Environment temperature-10ºC~+50ºC
Environment humiditySmaller than 95%RH, no drop condenses
VibrationSmaller than 5.9 M/S2(0.6g)
Storage temperature-40ºC~+70ºC
StructureProtection gradeIP20
Cooling modeForced air cooling and natural
Installation modeWall hanging and cabinet installation
 

















Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA