Product description, technical parameters and configuration
Single-chip microcomputer control, Touch LCD Screen (7 inches)
Large LCD display can display multiple sets of data
Huge memory space to store multiple sets of data and curves
Auto zero,100% adjustment function
Wavelength automatic adjustment
Wrap lights, automatic filter change , large sample pool (0.5mm ~ 100mm)
Standard samples having a maximum ten-point standard curve measurement functions built
Direct input by K, B factor for quantitative measurement standard curve
Can be directly input and the corresponding standard concentration values establish a standard curve for quantitative measurement
Adjustable electric saving standard curve parameter measuring set, can save a plurality of standard curve
an be edited at any time of the standard curve , user-friendly
General Parallel printer interface with or slightly beat interfaces can print the title bar, the measurement data , curve parameters , the standard curve and the curve sample points
With USB interface
PC control can be achieved through more accurate and flexible measurement requirements ( standard )
Software features
Wavelength Scan: the measured object can be 190nm-1100nm full band spectrum scan , can also be segmented scan
Kinetic tests: the time of the measured object scanning , timely detection of changes in concentration caused by changes in absorbance
Quantitative measurement: by establishing a standard curve , the concentration can be measured in the analysis was
Multi- wavelength testing : set a plurality of wavelengths simultaneously , the measured absorbance of a plurality of wavelengths in the test
DNA / protein test: the test formula purity of nucleic acid and protein concentration analysis of DNA / protein
Technical Specifications
Wavelength Range | 190~1100nm |
Band Width | 4nm |
Wavelength Accuracy | ±0.3nm |
Wavelength Repeatability | ≤0.1nm |
Photometric Accuracy | ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A) |
Photometric Repeatability | 0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A) |
Stray Light | ≤0.03% τ (220nm NaI,340nm NaNO2) |
Stability | 0.0005A/h@500nm |
Noise | ± 0.0002A @500nm |
Baseline Flatness | ± 0.001A |
Photometric Mode | T,A,C,E |
Wavelength Setting | Automatic |
Photometric Display Range | -4~4A |
Display Mode | 6 inches high brightness blue LCD |
Detector | Import Silicon Photodiode |
Light Source | Import De Lamp & Tungsten Halogen Lamp |
Power Requirement | AC 220V/50Hz 110V/60Hz |
Power | 120W |
Dimensions(W*D*H) | 560×450×230mm |
Weight | 28Kg |
Photos: workshop: