Mining Explosion Proof Transformer
Power
Three
ISO9001-2000, ISO9001
Power Transformer, Distribution Transformer
Jsm
Yy0(D11), Dyn11 or Others
6, 10, 11kv
50 or 60 Hz
0.693, 0.4, 1.2, 3.45
Transformer
JSM
China
Product Description
1)22 years' manufacturing experience with three subsidiaries
2)authoritative type test report
3)win tender in foreign country
The KBSG series mining explosion isolation dry transformer conforms to new GB8286, mineral product separates explode migration transformer suubstation requests. Insulating the material adops C class or H class to insulate, hot stabiliby good, cooling offway a doption ANAN. Be applicable to three are air and coal dust of the mountain, tunnel of explosion danger etc. Environment, also be APP licable to shortage with air and steam environment which decays metals and breakage to insulate. Settle the frequency as 50Hz, a primary voltage is 6kVs or 10kVs, andneutergender not to cnnnect ground for the power system, for use various motive equipments in the environment with various use electricity device to provide power supply



2)authoritative type test report
3)win tender in foreign country
The KBSG series mining explosion isolation dry transformer conforms to new GB8286, mineral product separates explode migration transformer suubstation requests. Insulating the material adops C class or H class to insulate, hot stabiliby good, cooling offway a doption ANAN. Be applicable to three are air and coal dust of the mountain, tunnel of explosion danger etc. Environment, also be APP licable to shortage with air and steam environment which decays metals and breakage to insulate. Settle the frequency as 50Hz, a primary voltage is 6kVs or 10kVs, andneutergender not to cnnnect ground for the power system, for use various motive equipments in the environment with various use electricity device to provide power supply
Technical Data of 10kV KBSGZY Series Dry Type Mining Explosion Isolation Movable Transformer Substation | ||||||||||||
Loss (kW) | Weight (kg) | (mm) | Gauge(mm) | |||||||||
Rated Capacity | Voltage Group(kV) | Connection Method | (145) | No-load current | Impedance | (L) | (W) | (H) | ||||
(kVA) | HV | LV | No-load | Load | % | % | Dimension | |||||
50 | 10± 5% | 0.693/0.4 1.2/0.693 1.2 3.45 | Yy0 (d11) | 390 | 680 | 2.5 | 4 | 2400 | 3200 | 950 | 1295 | 600 |
100 | 560 | 1050 | 2.5 | 4 | 2800 | 3580 | 950 | 1430 | ||||
200 | 950 | 1800 | 2 | 4 | 3200 | 3990 | 950 | 1525 | 600 900 | |||
250 | 1100 | 2100 | 2 | 4 | 3500 | 4020 | 950 | 1540 | ||||
315 | 1300 | 2500 | 1.8 | 4 | 3800 | 4050 | 980 | 1555 | ||||
400 | 1500 | 3000 | 1.8 | 4 | 4000 | 4200 | 1050 | 1610 | ||||
500 | 1750 | 3500 | 1.5 | 4 | 4300 | 4200 | 1050 | 1610 | ||||
630 | 2000 | 4100 | 1.5 | 4 | 5400 | 4370 | 1080 | 1450 | ||||
800 | Yy0 (d11) Dyn11 | 2300 | 5100 | 1.2 | 4 | 5700 | 4370 | 1080 | 1600 | |||
1000 | 2600 | 6100 | 1.2 | 4.5 | 6900 | 4400 | 1110 | 1675 | ||||
1250 | 3100 | 7400 | 1 | 4.5 | 7300 | 4480 | 1125 | 1740 | ||||
1600 | 3800 | 8500 | 1 | 5 | 9300 | 4640 | 1245 | 1830 | ||||
2000 | 4500 | 9700 | 0.7 | 5 | 11900 | 4665 | 1250 | 1900 | ||||
2500 | 5200 | 10800 | 0.7 | 5.5 | 14930 | 4870 | 1390 | 1900 | ||||
3150 | 6100 | 12800 | 0.7 | 5.5 | 19350 | 4880 | 1390 | 1900 | ||||
4000 | 7000 | 15000 | 0.7 | 6 | 21910 | 5210 | 1450 | 1900 | ||||
(Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz. The above data provides a reference only, movable transformer sustation the basis switch of the shape size of transformer substation different but different. |