Large-Capacity Dry Type Transformer Cast Resin Copper

Price Negotiable Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 315 people viewed
Quantity
+-
 

JINSHANMEN TECHNOLOGY CO., LTD.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
Three
Jsm
Yyn0, Dyn11 or Others
11, 10.5, 10, 6.3, 6, Kv
50 or 60 Hz
0.4, 0.433kv or Others
Transformer
JSM
China
Product Description


1) 22 years' manufacturing experience with three subsidiaries
2) Authoritative type test report
3) KPLC's supplier in Kenya
3) IP54
Tech data of 10kv, 11kv SCZ(B)10 series on-load tap changer resin insulation dry-type power transformer

1. Standards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726
2. Voltage Grade: 6, 10, 6.3KV, 11kV
3. Voltage Regukation Mode: Off circuit tap changing; On load tap changing
4. Tapping Range: ± 5%, ± 2× 2.5%, ± 4× 2.5% or others
5. Frequency: 50Hz; 60Hz
6. Phase: Three phase
7. Connection Sign: Yyn0, Dyn11 or others
8. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
9. Max. Temperature: 120K
10. Cooling Method: ONAN or ONAF
11. Insulation Class: Grade F

Features:
High voltage coils are wrapped with Polyester enameled wires, filled with glass fiber, and then resin under vacuum condition. It becomes solid under high temperature. It equipped with high mechanical intensity, low discharge partly; Low voltage coils are wrapped with a whole piece of copper foil, with strong anti-shortcut capacity. The core is made of silicon steel. By reasonable choosing magnetic density, decrease the empty loading loss effectively
Fire protection, anti-explosion, and no pollution
Coil is free from humidity, low noise and well characteristic of heating dispersion
Low loss, energy saving, free from maintenance, small size, light, and easy for installation
Technical Data of 11kV SCZ(B)10 F-Grade OLTC Cast Resin Insulation Dry Type  Power Transformer
   Loss (kW)    (mm)
Rated CapacityVoltage Group(kV)Connection Method                 (120)No-load currentImpedance VoltageInsulation LevelWeight(L)(W)(H)
(kVA)HVLVNo-loadLoad%% (kg)Outline Dimension with Protective casing
200   0.692.661.64 1180145018501600
250   0.792.91.6 1290150019001600
315   0.973.611.4 1430150019501600
400   1.084.241.4 1700160020001600
500   1.285.151.4 1880160020501600
63011  1.4756.271.26 2150160020501650
80010.5 Dyn111.677.41.2F/F2540190020501800
1000100.4 1.958.761.1 2950195020501950
1250 Yyn02.310.541.1 3380205021002000
16006.3  2.712.411.1 3990210021502100
20006  3.6815.221 4400215022502100
2500   4.418.11 5060220022502200
3150   5.6523.630.88 6050235023502250
4000   6.5628.350.8 7350240023502300
(Note): (Tapping range of high voltage) ± 4× 2.5% or ± 3× 2.5%, Frequency: 50Hz.