146mm Squirrel Cage Duel Inlet Centrifugal Blower
Brand New
Blower Fan
0~10V /PWM Speed Control, Tach Output
Ec Brushless External Rotor Motor
48 VDC
106W
1580rpm
960m3/H
248PA
PBM
2PCS/Carton, 48PCS/Pallet
92mm motor, 146mm dia. impeller
Suzhou
8414593000
Product Description
48VDC Squirrel Cage Duel Inlet Centrifugal Blower Fan with 146mm Impeller
Model No.:PD3N146B48H

1.General Characters
Model | PD3N146B48H |
Rated Voltage | 48VDC |
Operating Voltage | 36~57VAC |
Rated Speed | 1580 RPM |
Input Current | 3.0A |
Input Power | 144W |
Air Flow | 960m3/H |
Static Pressure | 248 Pa |
Sound Level | 61 dB(A) |
Protection Type | IP44 |
2.Mechanical Characters
Dimension | 209mm X219mm X270mm (see dimension drawing) |
Material of Impeller | Propylene with glass-fiber reinforced |
Mounting Position | Any |
Surface of Rotor | Coated in black |
Bearing System | NMB ball bearing |
Lead Wire | D2 |
Weight | 4500g |
Package | Standard |
3.Environmental Characters
Locked-rotor Protection | Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage. |
under Locked Rotor | A, Typical inrush current when the motor is trying to re-start under locked rotor conditions is 2~4 times the normal running current reoccurring and for 16~20% of restarting cycle period. B, If he CL function is used this restarting inrush current is about the same as the normal running current. |
Reverse Polarity Protection | No damage if the positive and negative leads are reversed under maximum operation voltage conditions. |
Over Voltage Protection | The circuit will be shut down automaticlly when input voltage over threshold. And re-started when Voltage down to threshold below. |
Soft Start | In 5 seconds after power on and speed control voltage gets to 1.5V or PWM duty cycle at 10% above. |


Related Products

IP55 Fan Ec-AC Axial Fan Fan Ec-AC Axial Fan Forward Curved Centrifugal Fan Blower Fan with 146mm Impeller
FOB Price:US $51.4-57.4/Piece FOB Price:US $40.7-45.5/Piece FOB Price:US $51.2-57.2/Piece FOB Price:US $52-58/Piece
Contact Now Contact Now Contact Now Contact Now

Fan Ec-AC Backward Cur... Air Blower Fan Centrifugal Fan for HVAC Curved Centrifugal Fan
FOB Price:US $53.1-59.3/Piece FOB Price:US $49-56/Piece FOB Price:US $45.2-48.88/Piece FOB Price:US $73.95-75.78/Piece
Contact Now Contact Now Contact Now Contact Now




PBM Products Series
![]() | ![]() |
![]() | ![]() |
![]() | ![]() |
![]() | ![]() |



Q: What are electronically commutated motors?
Electronically Commutated motors are brushless DC motors where the direction of the electric current is switched using electronic controllers. As the switching of the current is technically known as 'commutating', brushless motors are also called 'electronically commutated' motors. EC motors provide the advantages of brushed DC motors in terms of the ability to have variable speed control, but without the drawbacks of brushes.Q: What are the advantages of EC motors?
EC motors are very high efficiency electric motors (80%) and maintain a high efficiency level at part speed. This means that in most cases they use less than one third to half of the electricity used by traditional induction motors, which in turn translates into lower operating costs and short payback periods. As EC motors have a higher efficiency this ensures that the motors run cooler in application which ensures a longer life for the motor.
In terms of speed control and features, because the motor's operation is controlled by software, EC motors allow customers to optimize and integrate the motor, fan and controller with the application, and to include features like data communications, constant volume control, variable speed.
Features & Advantages
Q: What about cost?
The initial outlay for an EC motor is more expensive than the traditional induction / shaded pole motors and this is mainly due to the electronic components required to drive the commutation. In recent years the cost of electronic components has reduced dramatically as volumes increase.
The huge energy savings provided by EC motors, mean equally large savings in operating costs, which in turn translate in payback periods as short as a few months combined with a longer life expectancy.
In our case, together with high energy savings, low use of raw material, low part count and simple electronics, have allowed us to make our motor price very competitive.
Q: How are EC motors 'sustainable'?
The huge energy savings provided by our EC motors directly translate into large carbon emissions savings.
By using an EC motors in your application we are able to assist our customers in dramatically reducing the air pollution (CO2) generated by their applications. This is due to the motors high efficency & low energy costs which helps to preserve the world for a 'greener' future.
EC Motors are designed & manufactured using 70% less copper and 80% less steel than traditional induction and shaded pole motors which has a dramatic reduction in environmental impact in producing these raw material components.
services to the clients.
Contact Us
We highly appreciate your any enquiry by email, call or instant message.