AM1000EX. SIL Isolated Barrier
Automatic Control, Protection
CCC
New
Customized
Reverse Protection
250V AC
2500V AC
-40ºC to +80ºC
10% to 90%
-20 ºC to + 60 ºC
1 in/1 out, 1 in/2 out, 2 in/2 out
Independent Power Supply
HollySys
Standard Packing
114.5mm× 99.0mm× 17.5mm
China
8481804090
Product Description
AM1000EX. SIL series functional safety isolation safety barrier adopts electromagnetic coupling technology to achieve reliable isolation of power supply, signal input and signal output, which is more reliable and safe than Zener gate, and does not need intrinsically safe grounding, which greatly enhances the anti-interference ability of detection and control loop. It is a general-purpose isolation safety barrier, which can meet the matching of various on-site intrinsic safety instruments. At the same time, it has obtained the German TUV functional safety certification.
Features
· Power supply: Independent power supply
· Number of channels: 1 in/1 out, 1 in/2 out, 2 in/2 out
· Functions: signal isolation transmission, transmission conversion, distribution
· Matching signal and intrinsically safe instrument:
Switch, proximity Switch Input
Intrinsically safe power supply output for driving intrinsically safe solenoid valves and indicator lamps
Two-wire and three-wire transmitter input (including HART)
Current signal input/output
Thermocouple, millivolt signal, thermal resistance input
Standards
· GB/T 3836.1-2021 "Explosive Environments Part 1: General Requirements for Equipment"
· GB/T 3836.4-2021 "Explosive Environments Part 4: Intrinsically safe 'i' Protected Equipment"
· GB/T 3836.20-2010 "Explosive Environments Part 20: Equipment Protection Rank (EPL) Ga Devices"
· IEC 61508 Parts 1-7: 2010
· IEC 61326-3-1: 2017
· IEC 61298 Parts 1-3: 2008
Certificates
· National Instrument Explosion-proof Safety Supervision and Inspection Station Explosion-proof certification
· AM1000EX.SIL series isolation grid, explosion-proof certificate number: GYB18.1229
· Chinese National Compulsory Product Certification (CCC)
General Technical Parameters
· Power supply protection: power supply reverse protection
· Safety isolation: Safety side and dangerous side isolation safety voltage 250V AC
· Insulation strength: 2500V AC; 1min (intrinsically safe end and non-intrinsically safe end) electromagnetic compatibility:
· Electromagnetic compatibility:
IEC 61326-1 (GB/T18268), IEC 61326-3-1
Electrostatic: air discharge 8kV
Pulse group: power line to ground 3kV, signal line to ground 2kV Surge: line to ground 2kV, line to line 2kV
Radio frequency: 20V/m
· Using environment:
It must be installed in a safe environment without explosive gases, and there must be no strong vibration, impact, or corrosive gases and dust in the surrounding environment
Continuous working temperature: -20 ºC to + 60 ºC
Relative humidity: 10% ~ 90%
· Storage conditions:
Temperature:-40 ºC to + 80 ºC
Relative humidity: 10% to 90%
Structure and Dimensions
· Instrument structure: DME series molded case structure
· Installation method: in a safe place, DIN35mm standard guide rail
· Terminal block: pluggable, blue terminal is connected to dangerous side signal, gray terminal is connected to safe side signal, 0.5 mm2 ~ 2.5 mm2 multi-bundle or single-strand cable can be connected
· Dimensions:
114.5 mm × 99.0 mm × 12.5 mm (depth × height × width)
114.5 mm × 99.0 mm × 17.5 mm (depth × height × width)

Packaging & Delivery
Related Products
AM2000EX Isolated Barrier

AM3000EX Isolated Barrier

AMG1000 Isolator

AML1000 Surge Protective Device (SPD)
Company Profile


Features
· Power supply: Independent power supply
· Number of channels: 1 in/1 out, 1 in/2 out, 2 in/2 out
· Functions: signal isolation transmission, transmission conversion, distribution
· Matching signal and intrinsically safe instrument:
Switch, proximity Switch Input
Intrinsically safe power supply output for driving intrinsically safe solenoid valves and indicator lamps
Two-wire and three-wire transmitter input (including HART)
Current signal input/output
Thermocouple, millivolt signal, thermal resistance input
Standards
· GB/T 3836.1-2021 "Explosive Environments Part 1: General Requirements for Equipment"
· GB/T 3836.4-2021 "Explosive Environments Part 4: Intrinsically safe 'i' Protected Equipment"
· GB/T 3836.20-2010 "Explosive Environments Part 20: Equipment Protection Rank (EPL) Ga Devices"
· IEC 61508 Parts 1-7: 2010
· IEC 61326-3-1: 2017
· IEC 61298 Parts 1-3: 2008
Certificates
· National Instrument Explosion-proof Safety Supervision and Inspection Station Explosion-proof certification
· AM1000EX.SIL series isolation grid, explosion-proof certificate number: GYB18.1229
· Chinese National Compulsory Product Certification (CCC)
General Technical Parameters
· Power supply protection: power supply reverse protection
· Safety isolation: Safety side and dangerous side isolation safety voltage 250V AC
· Insulation strength: 2500V AC; 1min (intrinsically safe end and non-intrinsically safe end) electromagnetic compatibility:
· Electromagnetic compatibility:
IEC 61326-1 (GB/T18268), IEC 61326-3-1
Electrostatic: air discharge 8kV
Pulse group: power line to ground 3kV, signal line to ground 2kV Surge: line to ground 2kV, line to line 2kV
Radio frequency: 20V/m
· Using environment:
It must be installed in a safe environment without explosive gases, and there must be no strong vibration, impact, or corrosive gases and dust in the surrounding environment
Continuous working temperature: -20 ºC to + 60 ºC
Relative humidity: 10% ~ 90%
· Storage conditions:
Temperature:-40 ºC to + 80 ºC
Relative humidity: 10% to 90%
Structure and Dimensions
· Instrument structure: DME series molded case structure
· Installation method: in a safe place, DIN35mm standard guide rail
· Terminal block: pluggable, blue terminal is connected to dangerous side signal, gray terminal is connected to safe side signal, 0.5 mm2 ~ 2.5 mm2 multi-bundle or single-strand cable can be connected
· Dimensions:
114.5 mm × 99.0 mm × 12.5 mm (depth × height × width)
114.5 mm × 99.0 mm × 17.5 mm (depth × height × width)

Packaging & Delivery
Category | International Commercial Terms (Incoterms) | Terms of Payment | Nearest Port |
AM1000EX.SIL Isolated Barrier | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |
Related Products
AM2000EX Isolated Barrier

AM3000EX Isolated Barrier

AMG1000 Isolator

AML1000 Surge Protective Device (SPD)