Primary Current Injection Injector Tester with Temperature Rise Testing

Price $30000.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 277 people viewed
Quantity
+-
 

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
DDG-6000A
Life Time Maintenance
One Year
Power Current Test Equipment
Digital
Manual Control
0-100Kg
AC380V
GOLDSOL
Aluminum Box Inside and Plywood Case Outside
CE
China
9030339000
Product Description
I. Introduction
Strong current generator is the necessary equipment in places of strong current. It is widely used in power plants, power distribution stations, electrical manufacturers, research institutes and other departments. The equipment has the characters of short-term or intermittent system, small size, light weight and easy maintenance and so on.

II. Structure
The product has full metal shell and aluminum-alloy panel combination with  reasonable structure, elegant appearance, light weight and easy move.


1: Start  Button      2: Stop Button   3: Current Regulation Handle
4: Current Switch  5: Strong Current Indicator 6: Power Indicator
7: Weak Current Indicator 8: Voltage Switch 9: Operation Indicator
10: Voltage indicator   11: Strong Current Output   12 & 13:Power Input


III. Instructions

1.Connect the current amplifier with the tested product according to the testing requirements, and make sure that there's power supply. (For split type, connect the "input" on the panel with the power, the "output" with the "input" on DDK, and the "instrument" with the "instrument" on DDK.

2.
Select the position of Current Switch according to the needed current.

3.
Turn on the power, and the green light should be on (if not, turn the Voltage Switch counterclockwise to zero until the green light is on). Press the Startup Button, the green light should be off and the red light is on. Turn the Voltage Switch clockwise until the current rises to the needed level.

4.Turn the Voltage Switch counterclockwise to zero, press the Stop Button, the red light is off and the green light is on. The testing is over.



IV. Electrical Diagram
1. Diagram of Current Generator
   
2.Output copper wires connection method at open-backed door: 

V. Maintenance Notes
1. when acceptance of goods, please check the main circuit terminal block if it is loose, or if elecrical brush of regulator is with a  good contact.

2. when not using for a long time, please check the main circuit of insulation earth resistance with 500V Megohmmeter before the equipment will be used, the resistance should be not less than 0.5 MΩ.

3. Input voltage value should be ± 10%, frequency 50HZ.

4. Current switch are not allowed to operate with load.

5. Operation should be equably & slowly rotating hand wheel to avoid damaging the regulator.

6. Full load hours should not exceed 5 minutes, continuous work time should be less than 2.5 minutes, but the working cycle should be more than 10 minutes.

7. Earth terminal should be well grounded.


VI. Technical Parameters and Specifications for DDG series (Single phase)
 

Model
Capacity of Current Amplifier
(KVA)
Capacity of Voltage Regulator
(KVA)
Supply Voltage
(V)
No.of Phase
Remark
DDG-500A322201 1 unit
DDG-1000A652201 1 unit
DDG-1500A9102201 1 unit
DDG-2000A1210220 /380121unit/2unit 
DDG-2500A1510380121unit/2unit 
DDG-3000A1815380 21unit/2unit 
DDG-4000A2420380 22 unit
DDG-5000A3028380 22 unit
DDG-6000A3630380 22 unit
DDG-8000A4840380 22 unit
DDG-10000A6050380 22 unit
DDG-15000A9075380 22 unit
DDG-20000A120100380 22 unit


  VII. Accessories
 Sr noDescriptionQtyRemarks
  1Power supply cable1 
  2Connection cables1 
  3Earth cable 6m1 
  4Operating manual1 
  5Factory's calibration1 
  6Strong current cables2For buyer's option