S-250-12
Single
2 Years
201 - 300W
110VAC/220VAC
Series Switching Power Supply
Separate-excited Switching Power Supply
Frequency Modulation Type
Terminal Power Distribution Equipment
One-way Transmission
PWM
Ce CCC RoHS
Smun
250W
12VDC 20A
85-264VAC 240-370VDC
215*115*50mm
0.95kg
16PCS/16kg
-10~+60 Degree C,20%~90%Rh
En60950 UL60950 GB4943
Available
Available
Smun
Standard exporting carton
CE ROHS ISO9000
China
8504401400
Product Description
Model | S-250-12 | S-250-15 | S-250-24 | S-250-48 | |
Output | DC output Voltage | 12V | 15V | 24V | 48V |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 20A | 16.7A | 10A | 5.2A | |
Related Power | 250w | 250w | 250w | 250w | |
Wave&Noise | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 30ms | ||||
Input | Voltage Range | 85 ~132VAC 170-264VAC 47-63HZ 240-370VDC | |||
Input Current | 4A/115VAC 2A/230VAC | ||||
Efficiency | 79% | 80% | 81% | 82% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | ||||
Leakage current | <0.5mA/240VAC | ||||
Protection | Overload | Related output power 105-150% start overload protection | |||
Protection type: cutoff output, recovery after restart power | |||||
Over voltage | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | 55V-64.8V | |
Hiccup mode,recovers automatically after fault condition | |||||
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |||
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||||
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |||
I/P-FG:1.5KVAC 1min | |||||
O/P-FG:0.5KVAC 1min | |||||
Standard | Safety standard | Fit UL1012 | |||
Refer | Design refer to GB4943,UL60950,EN60950 | ||||
EMC standard | Design refer to GB9254,EN55022 Class A | ||||
Size | size | L215*W115*H50mm | |||
Package | 0.95kg, 16pcs/16kg |






