UPS
Single Phase
On-line
Unbalanced Loads
Fire Safety
Lighting/Power
Long-acting Machine
Sine Wave Output UPS
Small Type
Decentralized
Xinsilu
NICEA
Crate
282*145*220
China
3101
Product Description
Key Feature:
Zero Transfer time
True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues
DSP Digital Control Based
Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply
Ultra Wide Input Mains range
Strong compatible with ultra with electric environment, stay well with ultra wide range mains of 90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life
Best Loading Capability
Up to 0.9 Output Power Factor, 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application
Genset Compatible
Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.
High Input power factor
Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer
Reliable design
Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion
Open to customization
Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system
TECHNICAL SPECIFCATIONTrue Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues
DSP Digital Control Based
Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply
Ultra Wide Input Mains range
Strong compatible with ultra with electric environment, stay well with ultra wide range mains of 90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life
Best Loading Capability
Up to 0.9 Output Power Factor, 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application
Genset Compatible
Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.
High Input power factor
Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer
Reliable design
Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion
Open to customization
Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system
Tower Model | S1K | S1KL | S2K | S2KL | S3K | S3KL | S6K | S6KL | S10K | S10KL |
Phase | 1Phase 2Wire + PE | |||||||||
Capacity | 1KVA/900W | 2KVA/1.8KW | 3KVA/2.7KW | 6KVA/5.4KW | 10KVA/9KW | |||||
Input | ||||||||||
Nominal Input Voltage | 110 / 115 / 120 / 127VAC or 220 / 230 /240VAC | 220 / 230 / 240VAC | ||||||||
Input Voltage Range | 110 / 115 / 120 / 127VAC: 60V~300V Halfload 176V~300V Full Load 220 / 230 / 240VAC: 90V~300V Halfload 176V~300V Full Load | 110V~300V Halfload 176V~300V Full Load | ||||||||
Input Frequency Range | 40~70Hz | |||||||||
Input Power Factor | 0.99 @Full load | |||||||||
Output | ||||||||||
Output Voltage | 230Vac(220 / 240 / 208V Selectable) or 120Vac (100 / 110 /115 / 127V Selectable | 230V(220 / 240 / 208V Selectable) | ||||||||
Output Voltage Regulation | 1% | |||||||||
Output Frequency (Sync.Mode) | 46Hz ~ 54Hz / 57Hz ~ 63Hz | 46Hz ~ 54Hz / 56Hz ~ 64Hz | ||||||||
Output Frequency (Bat.Mode) | 50Hz+ / -0.05Hz 60Hz+ / -0.05Hz | |||||||||
Output THDv% | 2% Linear Load 6% Non-Linear Load | 2% Linear Load 5% Non-Linear Load | ||||||||
Output Waveform | Pure Sine Wave | |||||||||
Transfer Time | ||||||||||
Line mode ↔ Bat Mode | 0ms | |||||||||
Inv ↔ Bypass Mode | <4ms | |||||||||
Efficiency | ||||||||||
AC-->AC | 89% | 90% | 91% | >93% | ||||||
ECO | 94% | 95% | 96% | >95% | ||||||
Battery Mode | 87% | 88% | 89% | >90% | ||||||
Battery & Charger | ||||||||||
Battery Voltage/Capacity | 2 * 12V/7AH | 24V/36V External Battery | 4 * 12V/7AH | 48V/72V External Battery | 6 * 12V/7AH | 72V/96V External Battery | 12 * 12V/7AH | 144V/192V External Battery | 16 * 12V/7AH | 192V/240V External Battery |
Battery Type | Valve Regulated Maintenance Free Lead Acid (VRLA) for Standard Model with internal battery | |||||||||
Recharge Time | ~5 Hours | Subject to External Battery Config | ~5 Hours | Subject to External Battery Config | ~5 Hours | Subject to External Battery Config | ~5 Hours | Subject to External Battery Config | ~5 Hours | Subject to External Battery Config |
Max Recharge Current | 1.5A | 6A | 1.5A | 6A | 1.5A | 6A | 1.5A | 4A | 1.5A | 4A |
Floating Charge Votlage | 27.3V | 27.3V / 41.0V | 54.6V | 54.6V /81.8V | 81.8V | 81.8V/109.2V | 163.8V | 163.8V/218.4V | 218.4V | 218.4V/273V |
HMI | ||||||||||
Display | LED / LCD (Option) | |||||||||
Buzzer Alarm | Bat.Mode / Bat.Low / OverLoad / Fault | |||||||||
Communication Port | RS232 / SNMP (Option)/ USB(Option) | |||||||||
Physical | ||||||||||
Form Factor | Tower | |||||||||
Dimension(Tower) - W*H*L(mm) | 145*220*328 | 145*220*400 | 145*220*328 | 190*318*380 | 190*360*540 | 190*340*540 | 190*360*680 | 190*340*540 | ||
Weight(KG) | 8.9 | 6.1 | 17.5 | 10.6 | 21.6 | 10.8 | 37 | 15.4 | 48 | 16 |
Environment | ||||||||||
Humidity | 5~97% (Non Condensing) | |||||||||
Operating Ambient Temperature | 0~40oC | |||||||||
*External Battery Pack Rated Voltage Can Select Upon Order, 192 / 240V | ||||||||||
*Product Specifications are Subject to Change Without Notice. |