LC1K, LP1K
AC
3pole, 4pole
3
690V
6A, 9A, 12A, 16A
Ac Contactors
6A, 9A, 12A, 16A
Max 690VAC
120V 220V AC or 12V 24V DC
3 Pole, 4 Pole
DIN Rail or PCB
NewTrend or OEM
AC or DC voltage coil
China
853649
Product Description
LC1K and LP1K series is a complete range of compact mini style contactors and reversing contactors with common options available for ratings 6A, 9A, 12A, and 16 A. The offer includes a variety of different terminal connection choices and a wide range of coil voltage options. Compliance with standards: IEC 60947, VDE 0660, BS 5424, CE, etc.
- Available control circuits: AC, DC
- Applications: 2.2 kW, 4.5 kW, 5.5 kW in AC3 and AC4
- Terminal connection types include:
- Screw clamp
- Faston connectors
- Spring terminals
- Pins for printed circuit boards - 1 NO or 1NC contact embedded
- Available for 1 way motors, 2 way motors (reversing Contactors) and Star Delta pre- wired version
- Includes full range of control relays in the same design
- Possibility to extend the amount of auxiliary contacts thanks to additional auxiliary contact blocks
- Possibility to protect the motor thanks to additional thermal relays LR2K
Model Number | LC1K06 | LC1K09 | LC1K12 | LC1K16 | LP1K06 | LP1K09 | LP1K12 | LP1K16 |
Rated operational current (AC-3, 380V) | 6A | 9A | 12A | 16A | 6A | 9A | 12A | 16A |
Rated operational current (AC-3, 660V) | 5A | 7.5A | 10A | 12A | 5A | 7.5A | 10A | 12A |
Coil voltage (Control circuit voltage) | AC 230V 240V 380V 415V | DC 220V 230V 240V 250V | ||||||
Rated operational voltage | 380V, 660V | |||||||
Rated insulation voltage | 690V | |||||||
Main and auxiliary contacts | 3P+NO, 3P+NC, 2NO+2NC | |||||||
Motor power (AC-3, 220/240V) | 1.5KW | 2.2KW | 3KW | 3KW | 1.5KW | 2.2KW | 3KW | 3KW |
Motor power (AC-3, 380/415V) | 2.2KW | 4KW | 5.5KW | 7.5KW | 2.2KW | 4KW | 5.5KW | 7.5KW |
Motor power (AC-3, 440V) | 3KW | 4KW | 5.5KW | 7.5KW | 3KW | 4KW | 5.5KW | 7.5KW |
Motor power (AC-3, 500/660/690V) | 3KW | 4KW | 4KW | 4KW | 3KW | 4KW | 4KW | 4KW |
Mouting type | DIN Rail / PCB Solder Pin / Plate | |||||||
Coil Pull-In Voltage | 0.85-1.1 Us | |||||||
Coil Drop-Out Voltage | 0.2-0.75 Us | ≤0.2 Us | ||||||
Coil power | Pull-In 40VA, Maintain 4VA | |||||||
Coil power consumption | 1.2W | |||||||
Coil Pull-In time | 6-18 ms | |||||||
Coil Drop-Out time | 5-12 ms | |||||||
Electrical life | 500 thousand times | |||||||
Mechanical life | 100 thousand times | |||||||
Ambient air temperature | -5…40 °C | |||||||
Operating altitude | 2000 m without derating in temperature |
Standard control coil voltage CODE:
LC1K (AC voltage coil) | |||||||||||||||||
Volts (50/60Hz) | 12 | 20 | 24 | 36 | 42 | 48 | 110 | 115 | 120 | 127 | 200/ 208 | 220/ 230 | 230 | 230/ 240 | 256 | 277 | 380/ 400 |
Code | J7 | Z7 | B7 | C7 | D7 | E7 | F7 | FE7 | G7 | FC7 | L7 | M7 | P7 | U7 | W7 | UE7 | Q7 |
Volts (50/60Hz) | 400 | 400/ 415 | 440 | 480 | 500 | 575 | 600 | 660/ 690 | |||||||||
Code | V7 | N7 | R7 | T7 | S7 | SC7 | X7 | Y7 | |||||||||
LP1K (DC voltage coil) | |||||||||||||||||
Volts | 12 | 20 | 24 | 36 | 48 | 60 | 72 | 100 | 110 | 125 | 155 | 174 | 200 | 220 | 230 | 240 | 250 |
Code | JD | ZD | BD | CD | ED | ND | SD | KD | FD | GD | PD | QD | LD | MD | MPD | MUD | UD |
Example of complete model number:
LP1K09105BD:
LP1K means DC coil contactor, LC1K means AC coil contactor
09 means AC-3 9A rated current
10 means NO auxiliary contact, 01 means NC auxiliary contact
5 means PCB Solder Pin type, without 5 means regular DIN Rail type
BD means the coil voltage code
Dimension for DIN Rail mounting:

Dimension for PCB Solder Pin mounting: