Gv2me Enclosure IP55 Gv2mc02 Gv2mc03 IP41 Gv2mc01 Enclosed Starter Motor Protection Circuit Breakers Gv2me with IP55 Box

Price $8.00 Compare
Min Order 100 Pieces
Shipping From Shanghai, China
Popularity 416 people viewed
Quantity
+-
 

Shanghai Newtrend Electric Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
GV2ME
Low Voltage Circuit Breakers
Manual Type
Air
Fixed
ISO9001-2000, CE
Motor Protection
0.11A ~ 63A
Gv2me
Newtrend or OEM
NewTrend or OEM
China
Product Description
GV2ME Enclosure IP55 GV2MC02 GV2MC03 IP41 GV2MC01 Enclosed Starter Motor Protection Circuit Breakers GV2ME with IP55 box
 

Application

GV2ME/GV3ME series motor protection circuit breaker (Motor Manual Starter) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.

 

Setting Range of
Thermal Trips
(A)
Maximum Horsepower RatingsGV2ME
Pushbutton
GV2P
Rotary Handle
Single PhaseThree Phase
115V
(HP)
230V
(HP)
200V
(HP)
230V
(HP)
460V
(HP)
575V
(HP)
Catalog NumberCatalog Number
0.11 - 0.16
0.016 - 0.25
0.25 - 0.40
0.40 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
4 - 6.3
6 - 10
9 - 14
13 - 18
17 - 23
20 - 25
24 - 32
-
-
-
-
-
-
-
1/8
1/4
1/2
3/4
1
1-1/2
2
2
-
-
-
-
-
1/10
1/6
1/3
1/2
1-1/2
2
3
3
3
5
-
-
-
-
-
-
1/2
3/4
1-1/2
2
3
5
5
5
10
-
-
-
-
-
-
1/2
1
1-1/2
3
3
5
7-1/2
7-1/2
10
-
-
-
-
1/2
3/4
1
2
3
5
10
10
15
15
20
-
-
-
-
1/2
1
1-1/2
3
5
7-1/2
10
15
20
20
30
GV2ME01
GV2ME02
GV2ME03
GV2ME04
GV2ME05
GV2ME06
GV2ME07
GV2ME08
GV2ME10
GV2ME14
GV2ME16
GV2ME20
GV2ME21
GV2ME22
GV2ME32
GV2P01
GV2P02
GV2P03
GV2P04
GV2P05
GV2P06
GV2P07
GV2P08
GV2P10
GV2P14
GV2P16
GV2P20
GV2P21
GV2P22
1 - 1.6
1.6 - 2.5
2.5 - 4
4 - 6
6 - 10
10 - 16
16 - 25
25 - 40
40 - 63
-
-
1/8
1/4
1/2
1
2
3
5
1/10
1/16
1/3
1/2
1-1/2
2
3
7-1/2
10
-
1/2
3/4
1-1/2
2
3
5
10
20
-
1/2
1
1-1/2
3
5
7-1/2
10
20
3/4
1
2
3
5
10
15
30
40
1
1-1/2
3
-
7-1/2
10
20
30
60
GV3ME06
GV3ME07
GV3ME08
GV3ME10
GV3ME14
GV3ME20
GV3ME25
GV3ME40
GV3ME63
 

Auxiliary Contact Blocks
PictureDescriptionMounting
Location
Max. No. of
Blocks
Contact TypeCatalog Number
Instantaneous auxiliary contacts
GV2ME + GV3P
Frontbg1N.O. or N.C.
N.O. + N.C.
N.O. + N.O.
GVAE1
GVAE11
GVAE20
Left Hand Side2N.O. + N.C.
N.O. + N.O.
GVAN11
GVAN20
Fault signaling contact + instantaneous auxiliary contact GV2 + GV3PLeft Hand Side1N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C.GVAD1010
GVAD1001
GVAD0110
GVAD0101
Short circuit signaling contact
GV2 + GV3P
Left Hand Side1SPDTGVAM11
 

Voltage Trips

To order an undervoltage trip: replace the bullet (•) with a U (for example, GVAU025).
To order a shunt trip: replace the bullet (•) with an S (for example, GVAS025).

PictureOnly one trip or fault signaling contact can be installed per GV2ME/GV3ME device
DescriptionCharacteristicsVoltageFrequency  

Catalog

Number       

Voltage trips
GV2 & GV3P
Undervoltage or
Shunt trip
(external mounting,
1 block right side only)
24 V50 Hz
60 Hz
GVA•025
GVA•026
48 V50 Hz
60 Hz
GVA•055
GVA•056
100-110 V50/60 HzGVA•107
110-115 V50 Hz
60 Hz
GVA•115
GVA•116
120-127 V50 HzGVA•125
127 V60 HzGVA•115
200 V50 HzGVA•207
200-220 V60 HzGVA•207
220-240 V50 Hz
60 Hz
GVA•225
GVA•226
380-400 V50 Hz
60 Hz
GVA•385
GVA•386
415-440 V50 HzGVA•415
415 V60 HzGVA•416
440 V60 HzGVA•385
480 V60 HzGVA•415
500 V
600 V
50 Hz
60 Hz
GVA•505
Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
The GVAD is always mounted next to the starter.
For spring terminals, add 3 to the catalog number (for example, GVAE113).
One trip or one fault signaling can be fitted per GV3.
Cannot be used with GV2GH7 insulator.