Composite insulator
Low-voltage
Composite Polymer
Pin Insulator
A Type Insulator
Insulation, Electrical Installation
Spherical Type
70-100kv
CE, ISO9001
Grey
Optelec
Suspension Insulator;Pin Insulator; Post Insulator
Yes
OPTELEC
Cartons
CE, RoHS, SGS, ISO
China
85462090
Product Description


COMPOSITE INSULATORS
The Composite insulator includes epoxy glass fiber reinforced rod, silicon rubber umbrella skirt and metallic end fittings. We adopts complete injection technology to solve the key problem of interface electric spark puncture. Connection of the glass fibre rod and metal fittings adopts compression technique, equipped with full automatic sound wave detection system.
Features:
- High electrical and mechanical strength
- Good performance of hydrophobicity and sealing, strong anti-ageing and corrosion proof.
- Fine anti-pollution, strong prevent flash accident, and no need of manual cleaning, can be operated in high pollution areas.
- Small volume, light weight, easy for transportation and installation
1.

No. | Type | Rated voltage (kV) | Rated falling strength (KN) | Section length (mm) | Dry arcing distance (mm) | Min creepage d istance (mm) | Umbrella diameter (mm) | Lightning impulse with stand voltage (kV) | Power frequency 1 min wet withstand voltage (kV) |
1 | FXB-11/70CT | 11 | 70 | 350±15 | 160 | 500 | 125/90 | 75 | 50 |
2 | FXB1-15/70CT | 15 | 70 | 350±15 | 185 | 420 | 100 | 95 | 55 |
3 | FXB1-24/70CT | 24 | 70 | 455±15 | 275 | 650 | 100 | 155 | 70 |
4 | FXB1-24/70ST | 24 | 70 | 455±15 | 275 | 720 | 100 | 155 | 70 |
5 | FXB1-33/70CT | 33 | 70 | 500±15 | 320 | 840 | 100 | 75 | 200 |
6 | FXB-36/70CT | 36 | 70 | 640±15 | 365 | 860 | 100 | 80 | 210 |
7 | FXBW4-36/70SB | 36 | 70 | 670±15 | 455 | 1350 | 140/110 | 95 | 230 |
8 | FXBW4-36/70CT | 36 | 70 | 670±15 | 455 | 1350 | 140/110 | 95 | 230 |
9 | FXB-66/70SB | 66 | 70 | 890±15 | 704 | 2240 | 140/110 | 185 | 410 |
10 | FXB3-110/100 (120)SB | 110 | 100 (120) | 1260±15 1290±15 | 1050 | 3150 | 142/110 | 335 | 750 |
11 | FXB3-132/100 (120)SB | 132 | 100 (120) | 1395±15 1420±15 | 1150 | 3450 | 142/110 | 350 | 820 |

No. | Type | Rated voltage (kV) | Rated bending strength (KN) | Section length (mm) | Minimum Arc distance (mm) | Min creepage distance (mm) | Sheds distance (mm) | Full wave lightning impulse with stand voltage (kV) | Min power frequency 1 min wet withstand voltage (kV) |
1 | FPQ-11/5 | 11 | 5 | 270±15 | 140 | 350 | 138/110 | 60 | 45 |
2 | FPQ-15/5 | 15 | 5 | 330±15 | 195 | 490 | 138/110 | 65 | 140 |
3 | FPQ-24/8 | 24 | 8 | 390±15 | 260 | 720 | 140/112 | 70 | 145 |
4 | FPQ-33/8 | 33 | 8 | 445±15 | 295 | 1050 | 140/112 | 75 | 150 |
5 | FPQ-36/10 | 36 | 10 | 500±15 | 330 | 1200 | 140/112 | 95 | 200 |

No. | Type | Rated voltage (kV) | Min creepage distance (mm) | Rated mechanical failling load | Full wave lightning impulse with stand voltaga (kV) | Min Power frequency 1 min wet withstand voltage (kV) | Section length (mm) | Minimum Arc distance (mm) | |
Bending (KN) | Twist (KN.m) | ||||||||
1 | FXB-11/70CT | 11 | 560 | 6 | 1.2 | 45 | 110 | 470 | 230 |
2 | FXB1-15/70CT | 24 | 1250 | 8 | 1.5 | 95 | 180 | 585 | 310 |
3 | FXB1-24/70CT | 33 | 1250 | 8 | 1.5 | 95 | 180 | 740 | 475 |
4 | FXB1-24/70ST | 66 | 2160 | 12.5 | 2 | 170 | 350 | 865 | 740 |
4,

No. | Type | Rated voltage (kV) | Rated bending strength (KN) | Section length (mm) | Minimum Arc distance (mm) | Min creepage distance (mm) | Sheds distance (mm) | Full wave lightning impulse with stand voltage (kV) | Min power frequency 1 min wet withstand voltage (kV) |
1 | FZSW-11/4 | 11 | 4 | 215±15 | 130 | 290 | 105/78 | 75 | 42 |
2 | FZSW-15/5 | 15 | 5 | 260±15 | 185 | 600 | 138/112 | 105 | 55 |
3 | FZSW-24/8 | 24 | 8 | 355±15 | 255 | 750 | 138/112 | 145 | 65 |
4 | FZSW-33/8 | 33 | 8 | 420±15 | 340 | 1200 | 126/92 | 150 | 70 |
5 | FZSW-36/10 | 36 | 10 | 500±15 | 390 | 1200 | 138/112 | 175 | 75 |
6 | FZSW-69/12.5 | 69 | 12.5 | 760±15 | 640 | 2010 | 146/117 | 410 | 185 |
7 | FZSW-132/12.5 | 132 | 12.5 | 1200±15 | 1900 | 3200 | 190/152 | 650 | 230 |