VS1-12/1250-25
Mv Vacuum Circuit Breaker
Electric Type
High-Speed Circuit Breaker
Vacuum
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
VDE, ISO9001-2000, CE, CCC
630A, 1250A, 1600A,2000A, 2500A, 3150A, 4000A
12/24kv
30000 Cycles
50Hz
Common Insulated Cylinder
20ka, 25ka, 31.5ka, 40ka
150mm/210mm/275mm
Fixed & Withdrawable
Longxiang Electrical
Non-Solid Wooden Case
IEC: M2-E2-C2
Baoji, Shaanxi China
85389000
Product Description
11KV 1250A Fixed Type Vacuum Breaker Manufacture

General Description
ZN63A(VS1)-12 series of indoor vacuum circuit breaker is used for indoor 12kv switchgear,it is suitable to control and protect transmission
and distribution system such as electric network equipment and industrial&minning industry etc as their protection and control unit.
It can match with KYN28(GZS1), XGN and GG1-A series of switchgears. The products meet standards of GB1984-2003, this series of
products include:VCB truck, isolation truck and fuse truck etc.
1.This series of VCB is used integrated design for operating mechanism and VCB body with reasonable, beautiful and compact arrangement.
2.This series of VCB adopted vertical insulation house against impact due to different weather,it can effectively prevent VIS against damage by exterior factors.
3.With two kinds of installation unit:fixed type and withdrawable type,it can meet different assembling requirements between switchgear and breaker.
Applying ambient conditions
1.Ambient temperature:-10ºC~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.

Our Factory





Packaging & Delivery.



Welcome for enquiry and factory visit!

General Description
ZN63A(VS1)-12 series of indoor vacuum circuit breaker is used for indoor 12kv switchgear,it is suitable to control and protect transmission
and distribution system such as electric network equipment and industrial&minning industry etc as their protection and control unit.
It can match with KYN28(GZS1), XGN and GG1-A series of switchgears. The products meet standards of GB1984-2003, this series of
products include:VCB truck, isolation truck and fuse truck etc.
1.This series of VCB is used integrated design for operating mechanism and VCB body with reasonable, beautiful and compact arrangement.
2.This series of VCB adopted vertical insulation house against impact due to different weather,it can effectively prevent VIS against damage by exterior factors.
3.With two kinds of installation unit:fixed type and withdrawable type,it can meet different assembling requirements between switchgear and breaker.
Applying ambient conditions
1.Ambient temperature:-10ºC~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.

Our Factory





Packaging & Delivery.
Packaging Details | Non-solid wooden case(standard export package). |
Delivery Detail | Within 10~15 days from the date of receiving signed sales confirmation by both parties. |



Welcome for enquiry and factory visit!