11kv 1500kVA Tertiary Voltage Outdoor Oil Immersed Power Transformer

Price $50000.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 228 people viewed
Quantity
+-
 

Shenda International Engineering Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
SS-1500(1000+500)/11(6.6)-(1.05+0.415)
Power
Three
Core-type Transformer
Oil-immersed Type Transformer
Two-winding Transformer
ISO9001-2000, ISO9001
Power Transformer
Power Frequency
U
Eacher
Indoor/Outdoor
off Load – with Limit Switch
Onan
Toroidal
11kv
Silicon Sheet
Low Loss
+2.5%, -7.5% (5X2.5% Steps)
Less Than or Equal To1000m
-10 to +45 Centigrade
Dyn11yn11
Copper
Porcelain
65
EACHER
Sea Worthy Packing
CE, ISO, IEC, GB, ANSI
Jiangshan City, Zhejiang Province, China
Product Description
Product Description
11kv 1500kva Tertiary Voltage Outdoor Oil immersed Power Transformer



Introduction
  The performance of our S9 S10 S11 series 20kV and 35kV three-phase oil-immersed transformer conform to the standard of GB 1094-1996 "Power Transformer " and GB/T6451-2008 "Technical Parameter and requirements of Three-phase Oil-immersed Power Transformer". The iron core is made of quality cold -rolled silicon steel sheet , and the coil is made of quality oxygen-free copper, featuring good outlook and safe running . The products are widely used in power transmission and distribution of industrial and agricultural power networks.

Main function and features
   High reliability, advanced level of performances, reasonable economical indicators.
  The core joints are of stepped shape with this steps , and the surface of the core is coated with cured    paint to lower losses and noises.
  The winding has novel structure and its oil passage is reasonable designed composition. Its newly designed insulation structure helps enhance its mechanical strength and this short-circuit withstanding ability .
    The oil tank is in various types , all have good outlook .

Rated power
(kVA)

High Voltage
(kV)

H.V Tap range

Low Voltage
(kV)

Connection Symbol

Short-Circuit Impedance
(%)

No-load Loss
(W)

On-Load Loss
(W)

No-load Current
(%)
9 Type10 Type11 Type9 Type10 Type11 Type
306
6.3
10
10.5
±5%
±2×2.5%
0.4Dyn11
Yyn0
41301101006006006002.1
501701501308708708702
632001801501040104010401.9
802502001801250125012501.8
1002902302001500150015001.6
1253402702401800180018001.5
1604003102802200220022001.4
2004803803402600260026001.2
2505604604003050305030501.2
3156705404803650365036501.1
4008006505704300430043001
5009607806805150515051501
6304.512009208106200620062000.9
800140011209807500750075000.8
10001700132011501030010300103000.7
12501950156013601200012000120000.6
16002400188016401450014500145000.6
200052830227019401714017140171400.6
25003350269023002026020260202600.5

Rated power
(kVA)
Weight 
(kg)
Overall dimension(mm)Gauge
(mm)
Active
part
OiltotalLW
3018085310750720930400×400
5021090420780740950400×400
632801105208007501000400×400
803101105208207701040400×400
1003401205608257901020550×550
1253801306708307901120550×550
16048014077010706701085550×550
20056016089011407401160550×550
250670180107012107901200550×550
315750230123013809001230550×550
400930250145013809001300550×550
50010702601670149010001320550×550
63012903201960157010301390660×660
80015903502340162010501460660×660
100017404502760176011901590660×660
125020804903200178011401670660×660
160025306403950197012901750820×820
200030008004890210020502000820×820
2500330011806280233022102150820×820
Certifications


Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics

Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.


Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.


Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection


Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).

Packaging and transportation



Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .


Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance



FAQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA