11kv 800kVA/ 500kVA /1500kVA/ 1250 kVA /2500kVA Power Dry Type Transformer

Price $10000.00 Compare
Min Order 1 sets
Shipping From Zhejiang, China
Popularity 350 people viewed
Quantity
+-
 

Zhejiang Shenmeng Electric Power Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
SCB
Power, Electronic, Instrument, Lighting, Rectifier, Audio
Three
Core-type Transformer
Dry-type Transformer
Two-winding Transformer
ISO9001-2000, ISO9001
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Power Frequency
Ring
Sinm
2 Years
Power
Aluminum or Copper
Electronic Power Transformer
Autotransformer
Cast Resin Dry
Toroidal
Power Distribution Transformer
sinm
Zhejiang, China
Product Description
Product Description

SCB series dry type transformers refer to transformers in which the core and windings are not immersed in insulating oil. The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When natural air cooling, the transformer can run continuously for a long time under the rated capacity. When forced air cooling, the output capacity of the transformer can be increased by 50% in short time. It is suitable for intermittent overload operation or emergency accident overload operation; due to the large increase in load loss and impedance voltage during overload, it is in an uneconomic operation state, so it should not be kept in continuous overload operation for a long time.

1.Power Capacity: 30-16000KVA

2.Voltage Level: 10KV,20KV,35KV or Others

3.Type of Voltage Regulation: Off-circuit or On-Ioad

4.Tapping Range: ±5 %  ±2x2.5 % ±4x2.5 %

5.Frequency: 50Hz or 60Hz

6.Phases: Three or Single

7.Connection Symbol: Dyn11,Yyn0 ( or as requested)

8.Short- circuit Impedance:  Standard Impedance

9.Maxmun Temperature Rise: 100K

10.Insulation Class:Class F or H

11.Protection Class:IP00/IP20/IP23/IP40/IP50

12.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.

 

Dry Type Power Transformer Features:
Since epoxy resin is a non-flammable, flame-retardant, self-extinguishing solid insulating material, safe and clean, epoxy resin cast dry-type transformers are oil-free, non-flammable, and have low operating loss, strong short-circuit resistance, less maintenance work, high working efficiency, small volume and low noise. It is often used in places with high performance requirements such as fire prevention and explosion protection, and has the following practical characteristics:
1.It is safe, fireproof, pollution-free, and can be directly operated in the load center;
2.High mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability and long service life;
3.Low loss, low noise, obvious energy saving effect, maintenance-free;
4.Good heat dissipation performance, and capacity operation can be increased in short time when forced air cooling;
5.Good moisture resistance;
6.Dry-type transformers can be equipped with a complete temperature detection and protection system. Using intelligent signal temperature control system, it can automatically detect and display the respective operating temperatures of the three-phase windings, can automatically start and stop the fan, and have functions such as alarms and trips. IS485 communication interface can be installed to realize wireless detection and intelligent management.
7.Small size, light weight, less space and low installation cost.

 

Dry Type Power Transformer Standard:
IEC60076, GB/T1094.11, GB/T17211.


Dry Type Power Transformer Applicable Environment:
1.0-40 (ºC), relative humidity <70%;
2.Altitude: no more than 2500 meters;
3.Avoid rain, humidity, high temperature, high heat or direct sunlight. 
4.Prevent working in places where there are more corrosive liquids, or gases, dust, conductive fibers or metal fines;
5.Prevent working in vibration or electromagnetic interference places;
6.Avoid long-term storage and transportation upside down, and avoid strong impact.
 

Dry Type Power Transformer Technical Parameter:

ModelRated capacity (KVA)Connection symbolVoltage combination (KV)No-load loss (W)Load loss (W)No-load current (%)Short circuit impedance (%)
High-Tapping rangeLow-
voltagevoltage
SC(B)10-3030Yyn011±5%0.41907102.44
SC(B)10-5050or10.5±2×2.5%27010002.4
SC(B)10-8080Dyn1110 37013801.8
SC(B)10-100100 6.3 40015701.8
SC(B)10-125125 6 47018501.6
SC(B)10-160160   55021301.6
SC(B)10-200200   63025301.4
SC(B)10-250250   72027601.4
SC(B)10-315315   88034701.2
SC(B)10-400400   98039901.2
SC(B)10-500500   116048801.2
SC(B)10-630630   135058801
SC(B)10-630630   1300596016
SC(B)10-800800   152069601
SC(B)10-10001000   177081301
SC(B)10-12501250   209096901
SC(B)10-16001600   2450117301
SC(B)10-20002000   3050144500.8
SC(B)10-25002500   3600171700.8
SC(B)10-16001600   24501290018
SC(B)10-20002000   3050158900.8
SC(B)10-25002500   3600188900.8

 

SCB12/13/14/18 10KV/0.4KV 100kVA-3150kVA

            High Voltage:10(6,6.3,10.5,11)KV                              Connection Symbol:D,yn11 or Y,yn0                          Rated Frequency:50Hz/60Hz
            Low Voltage:0.4(0.415,0.433)KV                                  Tapping Range of HV:±2x2.5%                                Insulation Level:LI75 AC35/AC3
Rated power
(KVA)
Short-Circuit Impedance(%)SC(B)18 (W)SC(B)14 (W)SC(B)12/13 (W)No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm)Overall Dimension(mm)
No-Load LossOn-Load Loss75ºCNo-Load LossOn-Load Loss75ºCNo-Load LossOn-Load Loss75ºCLWHLWH
10042101120245112029012401.54559010706001160150011002200
1252451320290132034014601.34674011006001200150011002200
1602801510330151039016801.34681011306801240150011002200
2003301800380180045020001.14689011607201250150011002200
2503801960445196052521801.146105012207201300150011002200
3154652470545247064027401.046125012407601260170013002200
4005202840605284071531501.046142012608301240170013002200
5006103470720347084538601.046153012808701200170013502200
6307054180830418097546500.948181013308801230170013502200
63066804240805424094547100.948176014708801180170013502200
80079549509404950110555000.948209015009001130190013502200
1000930578010955780129064300.848250015709001220190013502200
12501095689012906890152076600.848292016109001330210015002200
16001290835015158350178092700.848365017209001420210015002200
20001600102801890102802220114200.750419017809801480230015002200
25001890122102230122102620135700.7505400200010201830230016002200
31502340146402695146403100161500.5506730203012702050235016002200
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

SCB12/13/14/18 20KV/0.4KV 200kVA-3150kVA
              High Voltage::20(15,22,24)KV                                   Connection Symbol:D,yn11 or Y,yn0                                     Rated Frequency:50Hz/60Hz
              Low Voltage:0.4(0.415,0.433)KV                                 Tapping Range of HV:±2x2.5%                                          Insulation Level:LI125 AC55/AC3
Rated power
(KVA)
Short-Circuit Impedance(%)SC(B)18 (W)SC(B)14 (W)SC(B)12/13 (W)No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm)Overall Dimension(mm)
No-Load LossOn-Load Loss75ºCNo-Load LossOn-Load Loss75ºCNo-Load LossOn-Load Loss75ºCLWHLWH
20063902090450209053023201.546125014607201350190013502200
2504402430520243061027001.346148014907201430190013502200
3155102900600290071032201.347155015107201470210014002200
4006103450710345084038201.148173015507201500210014002200
5007104120840412098045801.148198015808301550210014002200
63080048709504870111054101.049228016008301600210015002200
800920587010805870127065301.050318017308301760230015002200
10001080695012806950150077300.850358018008301780230015002200
12501250818014708180173090900.852368018209001850240015002200
160014609820172098202030109100.852468019809202040250016002200
20001700116002010116002360128800.753534022009602080270016002200
250082030137202400137202810152500.753648023309902170280017002200
31502510163302840163303320181500.6547530236012702250280017002200
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

SCB12/13/14/18 35KV/0.4KV 200kVA-3150kVA
            High Voltage: 35(33,38.5)KV                                Connection Symbol:D,yn11 or Y,yn0                          Rated Frequency:50Hz/60Hz
            Low Voltage: 0.4(0.415,0.433)KV                        Tapping Range of HV:±2x2.5%                                  Insulation Level: LI200 AC85/AC3
Rated power
(KVA)
Short-Circuit Impedance(%)SC(B)18 (W)SC(B)14 (W)SC(B)12/13 (W)No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm)Overall Dimension(mm)
No-Load LossOn-Load Loss75ºCNo-Load LossOn-Load Loss75ºCNo-Load LossOn-Load Loss75ºCLWHLWH
20064702360540236064026301.551155015909201790230016002200
2505202700610270072030101.351175015909201860230016002200
3156203210730321085035701.351195016508501750240017002200
40073038508503850100042801.151220018408901800240017002300
500850473010104730118052601.152264019109201800250017002300
630970548011505480135060901.052288019709302100260017002400
8001130583013405830157064801.0523530198010302030260018002500
10001280740015107400176082300.8524080207010602070270018002500
125014809040175090402060100400.8534430208010502080270018002500
16001710109602010109602360121800.8535310215010502180280018002600
20002010129602370129602780143900.7546410230010502250290018002700
250082340155002760155003240172300.7557630240011002230300020002700
31502890185903330185903830205100.6557530250012002350300020002800
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.
Basic structure of dry-type transformer
1. Iron core: stacked by silicon steel sheet, is the magnetic circuit part of the transformer, used to guide the magnetic flux.
2. Winding: divided into high-voltage winding and low-voltage winding, respectively wound on the iron core, used to realize the conversion and transmission of electric energy.
3. Insulating cylinder: placed between high and low voltage coils, used to increase electrical insulation and ensure the safe operation of the transformer.
4. pads: used to support and restrain the coils to maintain their stability and shape.
5. Fasteners: used to connect and fix each part of the transformer, with anti-loosening performance.
Three-Phase Epoxy Resin Cast Dry-Type Transformers Can Be Customized
1. Are you manufacturers ?
 We are a professional factory with 10 years experience in the field of High and low Voltage switch-gears,
Substation,transformers,cable distribution box and various electrical equipment, such as vacuum circuit breaker , load break switch etc.
2. Do you accept customized serveice ?
We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters
3. What is your terms of payment ?
T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and pack-ages before you pay the balance.
4. Can your product be customerized ?
Considering differences in voltage. frequency and other speciality of transformer product in different countries and regions,our product can be customerized according to your requirements.
5. How do you solve quality problems?
Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 1 days .