11kv Kbsg Dry Type Mining Explosion Isolation Dry Type Transformer Cupper/Aluminum200kVA

Price $7533.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 254 people viewed
Quantity
+-
 

JINSHANMEN TECHNOLOGY CO., LTD.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
KBSG 200KVA
Three
Dry-type Transformer
Distribution Transformer
Jsm
Yyn0, Dyn11 or Others
11; 10.5; 10; 6.3; 6kv
50 or 60 Hz
0.4, 0.433kv
Transformer
JSM
Exporting Wooden Case
Mine Transformer
China
8504210000
Product Description
1) 22 years' manufacturing experience with three subsidiaries
2) Top 3 in China
3) won tender abroad
4) IP54

Tech data:
1. Standards: GB1094-1996; GB8286-2005; GB3836-2000; GB/T10228-2008; EQV IEC726
2. Capacity Range: 50-4000kVA
3. Voltage Grade: 6, 11kV
4. Voltage Regukation Mode: Off circuit tap changing
5. Tapping Range: ± 5%, ± 2× 2.5% or others
6. Frequency: 50Hz; 60Hz
7. Phase: Three phase
8. Connection Sign: Yy0(d11), Dyn11 or others
9. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
10. Max. Temperature: 145K

Features:
The mineral product separates the explode migration transformer substation separaters the explode migration transformer substation by the mineral product with the do-like transformer, the high-pressured load switch either the high pressure and the low pressure switch ot he low pressure guarantees is composed
This series dry type mining explosion isolation movable transformer substation is a kind of movable whole set distribution and transformation device.
It has the protection of creepage, earth leakage, overload, short circuit, overvoltage, undervoltage etc

It is suitable for not only mines filled with firedamp mixed gas, grime and explosive gas, but also the gas and steam environment that can not erode metal and insulation.
Technical Data of 11kV KBSG Series Dry Type Mining Explosion Isolation Dry Type Transformer
   Loss (kW)  Weight (kg)(mm)Gauge(mm)
Rated CapacityVoltage Group(kV)Connection                 (145)No-load currentImpedance(L)(W)(H) 
(kVA)HVLVNo-loadLoad%% Dimension 
5010± 5%0.693/0.4 1.2/0.693  1.2          3.45Yy0              (d11)3906802.54140023109501295600
10056010502.54180024309501430
200950180024220027309501525600                  900
2501100210024250027609501540
315130025001.84280028009801555
400150030001.843000295010501610
500175035001.543300295010501610
630200041001.544400320010801450
800Yy0              (d11)  Dyn11230051001.244700320010801600
1000260061001.24.55900320011101675
12503100740014.56500325011251740
160038008500158300345012451830
2000450097000.7510900366512501900
25005200108000.75.513930378013901900
31506100128000.75.518350388013901900
40007000150000.7620910421014501900
(Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz. The above data provides a reference only, movable transformer sustation the basis switch of the shape size  of transformer substation different but different.