11kv15kv 33kv PVC Sheathd Aluminum PVC XLPE PE Insulated Underground Medium Voltage Mv Power Wire Copper Cable Industrial Armoured Yjv22 Yjv32 Yjv62 Electrical

Price $1.00 Compare
Min Order 500 Meters
Shipping From Hebei, China
Popularity 474 people viewed
Quantity
+-
 

Hebei Huatong Wires & Cables Group Co., Ltd.

VIP   Audited Supplier 10 years
Profile Certified by SGS/BV
YJV32 YJLV32
Construction, Underground, Power Station
Low and Medium Voltage Cable
AC Cable
XLPE
PVC
Round Wire
ISO
YJV
Huatong
11kv Power Cable
IEC60502
11kv 15kv 33kv
Copper or Aluminum
XLPE
PVC
Steel Wire Armour Steel Tape Armour Aluminum Wire
185mm2
TUV Psb
HuaTong
Standard Export Drum
IEC60502
Hebei, China
85444921
Product Description

 
33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Power Cable

1 Application:
 It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.

Standard: BS6622, BS EN/IEC 60228,IEC60502.2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armouring:

Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour: Red or Black

2. Using features :Medium Voltage Power Cable Underground 11kv 15kv 33kv XLPE Power Cable

1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius:Single core - Fixed: 15 x overall diameter;3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
Note:The single core armoured cables are used for D.C. system only. If used for A.C. system, the magnetic isolation should be applied on the steel armor wires of non-magnetical materials should be used.




 