12/24/36kv Epoxy Resin Sensor/Capacitive Insulator/Cast Resin Insulator with Capacitive Sensor/Insulator Sensor

Price $10.45 Compare
Min Order 1500 Pieces
Shipping From Zhejiang, China
Popularity 264 people viewed
Quantity
+-
 

Yueqing Yisi Electric Co., Ltd.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
TCI
High-voltage
FRP/GRP
Post Insulator
A Type Insulator
High Voltage Power Transmission, Insulation, Electrical Installation
Trough Type
7kn
CE, ISO9001
Red
Telehan
TELEHAN
One PCS Per Master Box
China
8546900000
Product Description

Capacitive Insulators


Note: With ceramic capacitors & side reading connection

General characteristics:

Epoxy resin post insulators with capacitive divider for the reading the present or absent of the voltage .Manufactured with internal porcelain capacitor and metal fitting, they are equipped with couplings, cable and low voltage light signal box. These insulators are mainly suitable to be used as insulated supports of equipment, bus bar or fuses.

   Size                                                     φ95 × 130(140/145/150/170)                           
Rated voltage12kV
MaterialEpoxy resin
Operation ConditionIndoor installation
 
   Size                                                     φ110 × 190(210/225)                           
Rated voltage24kV
MaterialEpoxy resin
Operation ConditionIndoor installation

 

   Size                                                      φ145 × 320(380)                           
Rated voltage24kV
MaterialEpoxy resin
Operation ConditionIndoor installation


Application:

Indoor installation at max working temperature of 85°C.

Reference standards:

IEC 60660 and IEC 60273 (electrical test)

Type test:

Complete type test done by EMC and approved by ministry of energy.

Working voltage and drawing:12/24/36KV




Installation instruction:

The voltage presence indicators are devices used to supply information about the main circuit status inside the equipment where the devices are installed. To each lamp placed inside the indicator (L1 L2 L3) corresponds one phase of the input line. The line voltage presence is indicated by switching of the relevant lamp. The signal of voltage presence necessary to switch the lamps is sourced out by a capacitive coupling with an insulator equipped with capacitive output. Diagram 1 demonstrates the proper connections.