MO00001556010/6011/0505
Fixed Resistor
Protective Resistor, Load Resistor
Welding or Insertion
Ceramic Metal Alloy Stainless Steel Sheetsu
Surface Mount
Fixed Resistor
Single Connection
Trapezoid
Linear Scale
Metor
Power Electric
ISO9000
Anhui Power Electric
Carton Packing
275x208mm
Bengbu, Anhui
8533900000
Product Description

/ Product Characteristics /
1.The product is used in subway grounding protection system, ac bus or DC bus overvoltage protection; It can also be used as brake resistance or energy-absorbing resistance of large equipment
2.Packaging: welding, insert
3Feature: low resistance, extra high power, excellent ability absorb energy in short time
2.Packaging: welding, insert
3Feature: low resistance, extra high power, excellent ability absorb energy in short time
/ Product Features /
1.It has good weldability performance, between the resistive element sheet-language films, the connecting point use resistance spot welding, non-contact resistance, strong,durable beautiful.
2.The resistor's value is stable, has a resistance - temperature complementary characteristics, the error of the total resistance value is smaller than the original old models (error does not exceed ± 7.5%).
3.Durable, long life
4.The resistance material is 304L stainless steel, not easy to rust. Can be used in harsh environments
2.The resistor's value is stable, has a resistance - temperature complementary characteristics, the error of the total resistance value is smaller than the original old models (error does not exceed ± 7.5%).
3.Durable, long life
4.The resistance material is 304L stainless steel, not easy to rust. Can be used in harsh environments
/ Outline (mm) /

/ Technical Features /
Ratedpower (W) | Resistor range (Ω) | Precision range | Dielectric strength (V) | duration of current applied | Impulse energy |
1KW | 0.01Ω ~ 0. 5Ω | ±5% ~±10% | 2500V ~ 5000V | ≤10s | 10KJ~3MJ |
/ Environmental use requirements /
Line No | Specifications | Use requirement |
1 | TCR | ND |
2 | Insulation requirements | ≥100MΩ |
3 | Protection requirements | The resistance material is 304L stainless steel, not easy to rust. Can be used in harsh environments |
4 | Installation requirements | Use where there is no severe vibration or jolting |
5 | Cooling requirements | Cool |
/ Derating Curve /

/ Product use area /
The product is used in subway grounding protection system, ac bus or DC bus overvoltage protection; It can also be used as brake resistance or energy-absorbing resistance of large equipment.


/ Product Show map /