EST500CF2
Fan Coil Unit
Galvanized Sheet
Higher
110V/220~240V-50Hz/60Hz-1pH
Low
HVAC
Ceiling Mount and Floor Standing
>20 years
CE
New
White
Two Pipe System/Four Pipe System
Zg 3/4"
Eurostars
Standard Export Packing, Such as Cartons
CE Approval
Guangdong, Prc.
84159010
Product Description
Energy Saving 2 Pipe Ceiling Mounted Floor Standing Fan Coil Unit
1. Ceiling floor fan coil features:
(1)Low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Flexible installation; (5) Easy operation.
In central air conditioner system, Eurostars ceiling exposed floor standing fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Ceiling floor fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Ceiling floor fan coil unit nomenclature
ES T 500 CF2 T R A O
1 2 3 4 5 6 7 8
1: ES Eurostars
2 :T Terminal series
3 :500 Rated air flow: CFM
4 :CF2 Ceiling exposed floor mounted and the number of tube system
5 :T Coil type: T-2C0H (Note: C-Cold water coil; H-Hot water coil)
6 :R Connection pipe direction: R-Right (face to air outlet) L-Left (face to air outlet)
7: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
8 :O Sales region: O-Other regions; C-Mainland China
3.Ceiling floor fan coil techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature 60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.
4.Ceiling floor fan coil unit product views

5.Ceiling floor fan coil unit installation illustration

6. Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit
1. Ceiling floor fan coil features:
(1)Low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Flexible installation; (5) Easy operation.
In central air conditioner system, Eurostars ceiling exposed floor standing fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Ceiling floor fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Ceiling floor fan coil unit nomenclature
ES T 500 CF2 T R A O
1 2 3 4 5 6 7 8
1: ES Eurostars
2 :T Terminal series
3 :500 Rated air flow: CFM
4 :CF2 Ceiling exposed floor mounted and the number of tube system
5 :T Coil type: T-2C0H (Note: C-Cold water coil; H-Hot water coil)
6 :R Connection pipe direction: R-Right (face to air outlet) L-Left (face to air outlet)
7: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
8 :O Sales region: O-Other regions; C-Mainland China
3.Ceiling floor fan coil techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Ceiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system) | |||||||||||
Model EST~ | 300CF2 | 400CF2 | 500CF2 | 600CF2 | 800CF2 | 1000CF2 | 1200CF2 | 1400CF2 | |||
Air flow (m3/h) | High | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||
Medium | 420 | 560 | 770 | 910 | 1210 | 1450 | 1850 | 2150 | |||
Low | 340 | 480 | 610 | 820 | 1100 | 1380 | 1600 | 2000 | |||
Cooling capacity | TH | H | W | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
BTU | 9215 | 12287 | 15359 | 18430 | 24574 | 30717 | 36860 | 43004 | |||
SH | W | 1990 | 2730 | 3174 | 4261 | 5385 | 6746 | 8109 | 9062 | ||
BTU | 6792 | 9317 | 10833 | 14543 | 18379 | 23024 | 27676 | 30929 | |||
TH | M | W | 2485 | 3030 | 3752 | 4467 | 6499 | 7926 | 9389 | 10605 | |
BTU | 8481 | 10341 | 12806 | 15246 | 22181 | 27051 | 32045 | 36195 | |||
SH | W | 1570 | 2015 | 2450 | 3070 | 4278 | 5447 | 6669 | 7262 | ||
BTU | 5358 | 6877 | 8362 | 10478 | 14601 | 18591 | 22761 | 24785 | |||
TH | L | W | 2078 | 2504 | 2950 | 3831 | 5660 | 7295 | 8619 | 8989 | |
BTU | 7092 | 8546 | 10068 | 13075 | 19318 | 24898 | 29417 | 30679 | |||
SH | W | 1212 | 1545 | 1844 | 2397 | 3317 | 4460 | 5300 | 5555 | ||
BTU | 4137 | 5273 | 6294 | 8181 | 11321 | 15222 | 18089 | 18959 | |||
Heating capacity | H | W | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | |
BTU/h | 13823 | 18430 | 23038 | 27645 | 36860 | 46076 | 55291 | 64506 | |||
M | W | 2792 | 3970 | 4941 | 5740 | 7987 | 10557 | 13101 | 14011 | ||
BTU/h | 9529 | 13550 | 16864 | 19591 | 27260 | 36031 | 44714 | 47820 | |||
L | W | 1788 | 2800 | 3533 | 3907 | 5464 | 7048 | 8714 | 9778 | ||
BTU/h | 6102 | 9556 | 12058 | 13335 | 18649 | 24055 | 29741 | 33372 | |||
Power Input | H | W | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |
Noise | H | dB(A) | 39.00 | 41.00 | 43.00 | 45.00 | 46.00 | 48.00 | 50.00 | 51.00 | |
Water Flow | m3/h | 0.46 | 0.62 | 0.77 | 0.93 | 1.23 | 1.54 | 1.85 | 2.16 | ||
Water resistance | kPa | 11.80 | 13.60 | 21.00 | 23.00 | 25.00 | 32.00 | 33.00 | 38.00 | ||
Heat Exchanger | Type | copper tubes with shutter-type hyperbolic aluminum fins | |||||||||
Working pressure | 1.6MPa | ||||||||||
Testing pressure | Airtightness test under pressurized water:3.3MPa | ||||||||||
Motor | Type | Single-phase capacitive motor equips with fine ball bearing, low noise,long service life | |||||||||
Power supply | 220V-/50HZ | ||||||||||
Protection grade | IP20 | ||||||||||
Insulation grade | B | ||||||||||
Pipe | Inlet/outlet water pipe | Rc 3/4 " internal thread | |||||||||
Condensation water pipe | ¢26 | ||||||||||
N.W. Kg | 31 | 31 | 31 | 41 | 41 | 46 | 46 | 46 |
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature 60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.
4.Ceiling floor fan coil unit product views

5.Ceiling floor fan coil unit installation illustration

6. Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit