Medical 400 Series Skin Temperature Probe Medical Grade Sterilized Temperature Sensor

Price $8.00 Compare
Min Order 500 Pieces
Shipping From Anhui, China
Popularity 253 people viewed
Quantity
+-
 

Hefei Jingpu Sensor Technology Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
JP402
Customized
RoHS
Small
Resistive
Analog Type
SUS304 & Epoxy&TPU
Gray or White
J. P. Sensor
Neutral Packing
metal disk Ф 9.50mm or Ф 12.0mm
Hefei, Anhui, China
9025191010
Product Description
Medical 400 Series Skin Temperature Probe Medical grade Sterilized Temperature Sensor
 
Product Description

The item is medical 400 series skin temperature probe medical grade sterilized temperature sensor. JP400 skin temperature probe is a pressed disk ceramic sensor. It is both FDA Registered and CE marked for selling globally.
As with all the 400 series probes Variohm offers, it has 2252.4ohm resistance at 25ºC and is interchangeable ±0.1ºC betwween 25ºC to 45ºC.

Shape and dimensions

Medical 400 Series Skin Temperature Probe Medical grade Sterilized Temperature Sensor

Product Features

CE MDD
Fast response through surface contact area
Standard 400 series resistance response
Standard 1/4'' phone plug connector
Reuse after cleaning
PTFE ribbon cable at thermistor
fast response, good stability, high accuracy, small size etc.
Medical 400 Series Skin Temperature Probe Medical grade Sterilized Temperature Sensor

Detailed Photos

Application: medical equipments, body temperature monitor, microwave hyperthermia etc.
Due to their fast response and high sensitivity, NTC thermistors are commonly used in applications like temperature control systems, temperature compensation, temperature monitoring, and thermal protection in electronic devices and industrial equipment.Medical 400 Series Skin Temperature Probe Medical grade Sterilized Temperature Sensor
You may also like these products:



Remarks: It's important to note that while NTC thermistors offer fast response times and high sensitivity, they do have some limitations. One key consideration is their non-linear response to temperature changes. The relationship between resistance and temperature is not linear and may require compensation or calibration to obtain accurate temperature readings. Additionally, NTC thermistors may have limited accuracy compared to other temperature sensors, such as resistance temperature detectors (RTDs) or thermocouples, especially over an extended temperature range
Medical 400 Series Skin Temperature Probe Medical grade Sterilized Temperature Sensor