Product Description
Medical Disposable Temperature Sensor Probe 2.252K 10K CE Standard
Temperature sensors for Food & Medical Applications. Since most products for food and medical applications directly relate to the healthy and lives of people, their quality is strictly specified to be '' clean and sanitary'' in the food Sanitation Act and Pharmaceutical Affairs Act. Especially, in recent years, international restrictions such as HACCP and GMP have been applied in many cases and the importance of temperature measurement has been increasing.
For the temperature sensors which are used in manufacturing processes, ''sanitary design is a mandatory condition in order to retain a clean manufacturing environment without foreign substances and a microbiologically clean status.
Quick Details
Technical parameters
Tolerance of resistance value: ±3%
Tolerance of temperature: ±0.1ºC
Application
▪ Skin / coelom / body temperature measurement
▪ Adult / pediatric esophageal / rectal / air / skin temperature monitoring
▪ Medical equipment, healthy monitor
Disposable and reusuable medical temperature probe:
▪ Tympanic temperature sensor probe
▪ Foley catheter temperature sensor probe
▪ Skin temperature sensor
▪ General purpose temperature probe





Temperature sensors for Food & Medical Applications. Since most products for food and medical applications directly relate to the healthy and lives of people, their quality is strictly specified to be '' clean and sanitary'' in the food Sanitation Act and Pharmaceutical Affairs Act. Especially, in recent years, international restrictions such as HACCP and GMP have been applied in many cases and the importance of temperature measurement has been increasing.
For the temperature sensors which are used in manufacturing processes, ''sanitary design is a mandatory condition in order to retain a clean manufacturing environment without foreign substances and a microbiologically clean status.
Quick Details
Model No. | Shell | Wire specification | Body part |
JP405 | Epoxy coated | Insulated wire | Body surface |
Lead wire | Parallel wire / stranded wire, customized wire length | ||
Terminal | USB connector / Molex connector | ||
Tube | PVC shell | ||
Application | body surface temperature measurement, temperature monitoring |
Technical parameters
Tolerance of resistance value: ±3%
Tolerance of temperature: ±0.1ºC
2.252K NTC ------- Resistance VS temperature | |||||||
Temp (ºC) | Resistance (Ω) | Temp. (ºC) | Resistance (Ω) | Temp. (ºC) | Resistance (Ω) | ||
25 | 2252 | 30 | 1815 | 35 | 1471 | ||
26 | 2156 | 31 | 1739 | 36 | 1412 | ||
27 | 2064 | 32 | 1667 | 37 | 1355 | ||
28 | 1977 | 33 | 1599 | 38 | 1301 | ||
29 | 1894 | 34 | 1533 | 39 | 1249 |
Application
▪ Skin / coelom / body temperature measurement
▪ Adult / pediatric esophageal / rectal / air / skin temperature monitoring
▪ Medical equipment, healthy monitor
Disposable and reusuable medical temperature probe:
▪ Tympanic temperature sensor probe
▪ Foley catheter temperature sensor probe
▪ Skin temperature sensor