MFC-S6B
Adjust
Based on Customer's Requirements
Based on Customer's Requirements
Continuous
Automatic Control, Protection, Monitoring
RoHS, CCC, ISO: 9001, CE
New
Non-Customized
Sanki
Cartoon
190*53.6*94.5(L*W*H, mm)
Suzhou, China
8537109090
Product Description

Digital setting isplay The output voltage and frequency are set digitally, which facilitates the management of set values.
Slow start/stop function
Sensor timer function By connecting the sensor, the ON/OFF of the vibration machine can be controlled.
Running signal output Equipped with three output points synchronized with the vibration output.
Speed switching Two parameter modes are stored and can be switched.
Constant amplitude control Unified use of piezoelectric vibration sensors enables constant amplitude control.
Use the same operation panel as the piezo controller
Save space for users The large model requires 20% smaller installation space than the previous generation. Through multifunctional integration, the installation space is further reduced.
To operate the start/stop of the controller according to external control signal, either method of non-voltage contact signal or voltage signal (24VDC) can be used. Make connection to the external control terminal block by using the method 1 or 2 below while
watching out for the signal to be used and the connection method. When wiring, be careful not to make mistake about the polarity.
The current of 24VDC and 10mA or less flows between [S+] and [S-]. Carefully select the connection device (e.g., minute current relay).
Slow start/stop function
Sensor timer function By connecting the sensor, the ON/OFF of the vibration machine can be controlled.
Running signal output Equipped with three output points synchronized with the vibration output.
Speed switching Two parameter modes are stored and can be switched.
Constant amplitude control Unified use of piezoelectric vibration sensors enables constant amplitude control.
Use the same operation panel as the piezo controller
Save space for users The large model requires 20% smaller installation space than the previous generation. Through multifunctional integration, the installation space is further reduced.
To operate the start/stop of the controller according to external control signal, either method of non-voltage contact signal or voltage signal (24VDC) can be used. Make connection to the external control terminal block by using the method 1 or 2 below while
watching out for the signal to be used and the connection method. When wiring, be careful not to make mistake about the polarity.
The current of 24VDC and 10mA or less flows between [S+] and [S-]. Carefully select the connection device (e.g., minute current relay).

![]() | ![]() |
![]() | ![]() |