1250A Vs1-12 Vcb Side Mounted Vacuum Circuit Current Breaker

Price $720.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 412 people viewed
Quantity
+-
 

Shengsu Electric Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
ZN63-12 BESIDE TYPE
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Vacuum
Fixed
Vcb
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
ISO9001-2000
12kv
Withdrawable
630A/1250A/1600A/2000A
150mm/210mm
50/60Hz
Steel, Expoxy Resin
Yes
Zn63-12 Beside Type
Medium
1000times
0.1s
Not Exceeding Level 8
0.4~0.8m/S
-15-40
≤1000m
SHENGSU ELECTRIC CO., LTD
Wooden Case
pcs
China
Product Description
Place of Origin:Wenzhou Zhejiang China
Brand Name: SHENGSU
Model Number: VS1-12
Material: Stainless steel
Mechanical life: 20000 times
Color: White Red
Rated voltage: 12KV
 
VS1 (ZN63A) - 12 indoor high voltage vacuum circuit breaker, three-phase ac 50 hz, rated voltage of 12 kv power system of indoor switchgear, as power equipment, industrial and mining enterprises, power protection and control unit. Apply to working in the rated electric demand flow frequent operation, or more open circuit short circuit current.
The circuit breaker operating mechanism and circuit breaker unibody design of ontology. Either as a fixed installation unit, also can equipped with feed mechanism, form a handcart unit.
 
Product Parameters
 
No.ItemUnitTechnical Parameter
1Rated voltage KV7.2, 11, 12 , 13.817.5 , 24
2Rated frequency HZ50, 6050, 60
3Rated currentA630,800, 1000,1250, 1600630,800, 1000,1250, 1600
4 
1min Power frequency withstand voltage
 
wetKV3850
dryKV4860
5Brand BoerstnBoerstn
6Type side mountedside mounted
7Rated lightning impulse withstand voltageKV75125 /150
8Rated short circuit breaking current (Peak)KA63, 80, 100
9Rated active load and close circuit breaking currentA6350
10Rated short circuit breaking currentKA20 , 25 , 31.5
11Rated short circuit making current (peak)KA63, 80, 100
12Rated cable(line) charging breaking currentA50, 10050, 100
13Cable charge breaking current in earthing faultA2020
14Rated withstand current (peak)KA63, 80, 100
15Short time withstand current (4s)KA31.531.5
16Mechanism lifetimes1000010000

Using the environment conditions


Ambient air humidity: cap + 40 ° ºC, lower limit - 15 ° ºC
Height: < 1000 m (if need higher elevation, the rated insulation level increase)
Amplitude: the earthquake intensity is not more than 8 degrees
Air relative humidity, average no greater than 95%, on average no greater than 90%
No fire and explosion danger, serious pollution, chemical corrosion and the site of violent vibration