380V AC VFD CE 3-Phase 250kw Frequency Inverter

Price $1289.00 Compare
Min Order 1 Piece
Shipping From Hunan, China
Popularity 479 people viewed
Quantity
+-
 

Changsha Vekont Electric Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
G630-4T250G
High Frequency Converter Transducer
Triple
Vector Control Transducer
PWM Control
Voltage
Low Voltage Variable-Frequency Drive
AC-DC-AC Variable-Frequency Drive
Current Variable-Frequency Drive
Textile Special, Constant Torque Universal Type
Vekont
250kw
Single Phase Input Three Phase Output
220V
Vf Control: 0~1200Hz
1K~15kHz
Open-Loop Vector Control (SVC), V/F Control
1:200 (Open-Loop Vector Control)
≤40ms (Open Loop Vector Control)
Torque Increase Automatically Torque Increase 0.1%
Vekont
DHL
0.75KW
China
Product Description

Technical specifications
 Specifications

 
Maximum frequencyVector control: 0~600Hz
VF control: 0~1200Hz
Carrier frequency1k~15kHz: The carrier frequency can be adjusted automatically according to the load characteristics.
Input frequency resolutionDigital setting: 0.01Hz
Analog setting: Maximum frequency × 0.1%
Control methodOpen-loop vector control (SVC), V/F control
Starting torqueG-model: 0.5Hz/180% (open-loop vector control)
P-model: 0.5Hz/120% (open-loop vector control)
Speed range1:200 (open-loop vector control)
Speed stabilization accuracy
(Speed control accuracy)
Open-loop vector control: ≤±0.5% (rated synchronous speed)
Speed control stabilityOpen-loop vector control: ≤±0.3% (rated synchronous speed)
Torque response≤40ms (open loop vector control)
Overload capacityModel G: 150% of rated current for 60 seconds;
180% of rated current for 5 seconds
Model P: 120% of rated current for 60 seconds;
150% of rated current for 5 seconds
Torque IncreaseTorque increase automatically
Torque increase 0.1% to 30.0% manually
V/F curveThree types: linear; multi-point; squared V/F curve
Acceleration/Deceleration curvesLinear or S-curve acceleration and deceleration mode; Four kinds of acceleration and deceleration time; Acceleration and deceleration time range 0.0s~3000.0s
DC BrakeDC braking frequency: 0.0Hz~maximum frequency Braking time: 0.0~36.0 seconds
Braking action current value: 0.0%~100.0%
Jog controlPoint-to-point frequency range: 0.00Hz~50.00Hz;
Jog acceleration and deceleration time 0.0s~3000.0s
Simple PLC
Multispeed operation
Up to 16 speeds via built-in PLC or control terminals
Built-in PIDProcess control closed-loop control system can be realized easily
Automatic Voltage Regulation (AVR)Keep the output voltage constant when the grid voltage changes automatically
Torque limiting and control"Digger" feature: torque limiting during operation to prevent frequent overcurrent trips automatically;
Closed-loop vector mode for torque control



 
Power-up peripherals safety self-testPower-on safety detection of peripheral devices such as grounding, short-circuiting, etc. can be realized
Common DC bus functionRealize the function of DC bus shared by multiple inverters
JOG keyProgrammable key: Forward and reverse operation/spot operation function selection
Textile swing controlVarious triangle wave frequency control functions
Fast current limit functionBuilt-in fast current limiting algorithm
Reduces the probability of overcurrent reported Improves the anti-interference ability
Timing controlFunction: Setting time range 0h~65535h
Standardization of keyboard extension cablesCustomers may extend the keyboard by using a standard network cable
Run
 
Run command channelThree types of channels: operator panel given, control terminal given, and serial communication port given. Switchable in various ways
Frequency source10 types of frequency sources: digital, analog voltage, analog current, pulse, and serial port give and take. Switchable in various ways
Auxiliary frequency sources10 kinds of auxiliary frequency sources.
Realization of auxiliary frequency trimming and frequency synthesis flexible.
Input terminalStandard seven digital input terminals, up to nine digital input terminals (AI1, AI2 can be used as X (DI) terminals), compatible with active PNP or NPN input.
Two analog input terminals, of which AI1 can only be used as a voltage input and AI2 can be used as a voltage or current input.
Output terminalOne digital output terminal (bipolar output)
Two relay output terminals
Two analog output terminals, can be selected from 0/4mA to 20mA or 0/2V to 10V respectively, which can realize the output of physical quantities such as set frequency, output frequency and rotational speed.
Display and keyboard operationLED displayDisplay parameters
LCD displayOptional, Chinese/English prompts for operation content
LCD parameter copyQuick copying of parameters using the LCD
Key lock and function selectionPartial or full locking of keys, defining the scope of action of some keys to prevent misoperation.
Protection and OptionsProtective functionPower-on motor short-circuit detection, input and output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, over-heating protection, overload protection, etc.
Optional accessoriesLCD operation panel, brake unit, etc.

 
LocationIndoors, out of direct sunlight, free of dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water or salt, etc.
AltitudePlease use at a reduced rate
(below 1000 meters, above 1000 meters)
Environmental temperature-10ºC~+50ºC
 (please use at a reduced rating 40ºC~50ºC)
Humidity levelLess than 95% RH, no water droplet condensation
VibratoryLess than 5.9 m/s2 (0.6 g)
Storage temperature-20ºC~+60ºC
Contamination level2
Product standardProduct implementation of safety standardsIEC 61800-5-1:2007
Product implementation of EMC standardsIEC 61800-3:2005


1. The brake resistor resistance can not less than the recommended resistance value in the table.
2. Table ×2 indicates that two groups of braking resistors are used in parallel. Table ×3 indicates that three groups of braking resistors are used in parallel, and so on;
3. Inverter model name followed by "B" for the standard built-in braking unit model inverter. Otherwise without built-in braking unit. Choose the corresponding braking unit model according to its braking torque.
4. 18.5~30kW G-type mechanism braking unit is built-in optional. Please specify when ordering if neccessary. The standard configuration does not come with a braking unit;
5. The 5S,15S listed in the table refers to the continuous braking time.
Modular design of IGBTs:
More stable! More reliable!
More environmentally adaptable
GP (heavy/normal -duty) models
Reduced customer order inventory
Digital dual display keypads
The first line display value and the second line display value can be freely defined.
Keyboard body standard with tray
Convenient network cable direct external lead
One-click setting of industry-
specific machine parameters
Built-in macros for a variety of
industry-specific applications
Message Type
* Message Content
* Name  
* Phone
* Email