ASTM A36
1 Year
1 Year
ASTM A36 A572 Gr.50 API 5L
Welding
235-6400 Psi
Buna-N Packing, Viton, Silicone and etc
GREAT WALL
Wooden Box
4'' to 30''
China
Product Description
Full Encirclement Welded Split-Casing Sleeve
Type B Sleeves :




1. PLIDCO Type Full Encirclement Welded Split-Casing Sleeve are typically used for two applications:
pressure containing and non-pressure containing .
A. pressure containing
The application is pressure containing when the Split-Casing Sleeve is installed over a known leak .
For a pressure containing application, the wall thickness of Split-Casing Sleeve and all welds must be able to contain the full operating pressure of pipeline .
The longitudinal weld joint formed by the two halves of the Split-Casing Sleeve must be a full thickness butt weld .
The circumferential joint formed by the Split-Casing Sleeve welded to pipeline must be a full thickness fillet weld .
B. Non-pressure containing
The application is non-pressure containing if the Split-Casing Sleeve is not installed over a known leak and the intended use is only to reinforce a damaged area of the pipe.
The longitudinal weld joint formed by the two halves of theSplit-Casing Sleeve must be a full thickness butt weld .
The circumferential joint does not have to be welded, but should be sealed with a coating to prevent ground water from penetrating the crevice between the sleeve and the pipe .
If the circumferential joint is welded, the application should be assumed to be pressure containing and all the requirements of a pressure containing application now apply .
2. PLIDO Type Full Encirclement Welded Split-Casing Sleeve are usually fabricated in length of 5 or 10 feet.
But you can define the length of Split-Casing Sleeve as per your own demand .
Back-up strips for the longitudinal butt welds are furnished with all sleeves .
3. PLIDCO Type Full Encirclement Welded Split-Casing Sleeve conform to ASME B31.4 and B31.8 as well as US Department of Transportation (US DOT) requirements . Individual company codes and safety pratices should be observed .US DOT requires that population density be considered in the installation area for natural and other gas pipelines ( DOT section 192.5). Table showing maximum operating pressure PLIDCO Type Full Encirclement Welded Split-Casing Sleeve by size, materials of construction and class location are shown beside
4. Standard body materials
- ASTM A36
- ASTM A572 Gr.50
Recommended Working Pressure(PSI)
Class I
Sparsely populated areas
Class II
Fringe Areas Around Urban Centers
Class III
Average Commercial and Residential Areas
Class IV
Densely Populated Areas
2. Project Cases :




Type B Sleeves :




1. PLIDCO Type Full Encirclement Welded Split-Casing Sleeve are typically used for two applications:
pressure containing and non-pressure containing .
A. pressure containing
The application is pressure containing when the Split-Casing Sleeve is installed over a known leak .
For a pressure containing application, the wall thickness of Split-Casing Sleeve and all welds must be able to contain the full operating pressure of pipeline .
The longitudinal weld joint formed by the two halves of the Split-Casing Sleeve must be a full thickness butt weld .
The circumferential joint formed by the Split-Casing Sleeve welded to pipeline must be a full thickness fillet weld .
B. Non-pressure containing
The application is non-pressure containing if the Split-Casing Sleeve is not installed over a known leak and the intended use is only to reinforce a damaged area of the pipe.
The longitudinal weld joint formed by the two halves of theSplit-Casing Sleeve must be a full thickness butt weld .
The circumferential joint does not have to be welded, but should be sealed with a coating to prevent ground water from penetrating the crevice between the sleeve and the pipe .
If the circumferential joint is welded, the application should be assumed to be pressure containing and all the requirements of a pressure containing application now apply .
2. PLIDO Type Full Encirclement Welded Split-Casing Sleeve are usually fabricated in length of 5 or 10 feet.
But you can define the length of Split-Casing Sleeve as per your own demand .
Back-up strips for the longitudinal butt welds are furnished with all sleeves .
3. PLIDCO Type Full Encirclement Welded Split-Casing Sleeve conform to ASME B31.4 and B31.8 as well as US Department of Transportation (US DOT) requirements . Individual company codes and safety pratices should be observed .US DOT requires that population density be considered in the installation area for natural and other gas pipelines ( DOT section 192.5). Table showing maximum operating pressure PLIDCO Type Full Encirclement Welded Split-Casing Sleeve by size, materials of construction and class location are shown beside
4. Standard body materials
- ASTM A36
- ASTM A572 Gr.50
Recommended Working Pressure(PSI)
Class I
Sparsely populated areas
API Nominal Pipe Size (In.) | A-36 Steel Plate | A-572-Gr.50 Steel Plate | ||||||
1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | 1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | |
4 | 2529 | 3086 | 3617 | 4608 | 3512 | 4286 | 5023 | 6400 |
6 | 1788 | 2197 | 2592 | 3345 | 2483 | 3051 | 3600 | 4645 |
8 | 1401 | 1728 | 2046 | 2658 | 1946 | 2400 | 2842 | 3692 |
10 | 1139 | 1409 | 1672 | 2183 | 1582 | 1957 | 2323 | 3032 |
12 | 969 | 1200 | 1427 | 1868 | 1346 | 1667 | 1982 | 2595 |
14 | 886 | 1098 | 1307 | 1714 | 1231 | 1525 | 1815 | 2380 |
16 | 780 | 967 | 1152 | 1514 | 1083 | 1343 | 1600 | 2102 |
18 | 696 | 864 | 1030 | 1355 | 966 | 1200 | 1430 | 1882 |
20 | 628 | 781 | 931 | 1227 | 873 | 1084 | 1293 | 1704 |
22 | 573 | 712 | 850 | 1121 | 796 | 989 | 1180 | 1557 |
24 | 526 | 655 | 782 | 1032 | 731 | 909 | 1085 | 1433 |
26 | 487 | 606 | 723 | 956 | 676 | 841 | 1005 | 1327 |
28 | 453 | 563 | 673 | 890 | 629 | 783 | 935 | 1236 |
30 | 423 | 527 | 630 | 833 | 588 | 732 | 874 | 1157 |
Class II
Fringe Areas Around Urban Centers
API Nominal Pipe Size (In.) | A-36 Steel Plate | A-572-Gr.50 Steel Plate | ||||||
1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | 1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | |
4 | 2107 | 2571 | 3014 | 3840 | 2927 | 3571 | 4186 | 5333 |
6 | 1490 | 1831 | 2160 | 2787 | 2069 | 2542 | 3000 | 3871 |
8 | 1168 | 1440 | 1705 | 2215 | 1622 | 2000 | 2368 | 3077 |
10 | 949 | 1174 | 1394 | 1819 | 1319 | 1630 | 1935 | 2526 |
12 | 807 | 1000 | 1189 | 1557 | 1121 | 1389 | 1651 | 2162 |
14 | 738 | 915 | 1089 | 1428 | 1026 | 1271 | 1513 | 1983 |
16 | 650 | 806 | 960 | 1261 | 902 | 1119 | 1333 | 1752 |
18 | 580 | 720 | 858 | 1129 | 805 | 1000 | 1192 | 1569 |
20 | 524 | 651 | 776 | 1022 | 727 | 904 | 1078 | 1420 |
22 | 477 | 593 | 708 | 934 | 663 | 824 | 984 | 1297 |
24 | 439 | 545 | 651 | 860 | 609 | 758 | 905 | 1194 |
26 | 406 | 505 | 603 | 796 | 563 | 701 | 837 | 1106 |
28 | 377 | 470 | 561 | 742 | 524 | 652 | 779 | 1030 |
30 | 353 | 439 | 525 | 694 | 490 | 610 | 729 | 964 |
Class III
Average Commercial and Residential Areas
API Nominal Pipe Size (In.) | A-36 Steel Plate | A-572-Gr.50 Steel Plate | ||||||
1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | 1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | |
4 | 1756 | 2143 | 2512 | 3200 | 2439 | 2976 | 3488 | 4444 |
6 | 1241 | 1525 | 1800 | 2323 | 1724 | 2119 | 2500 | 3226 |
8 | 973 | 1200 | 1421 | 1846 | 1351 | 1667 | 1974 | 2564 |
10 | 791 | 978 | 1161 | 1516 | 1099 | 1359 | 1613 | 2105 |
12 | 673 | 833 | 991 | 1297 | 935 | 1157 | 1376 | 1802 |
14 | 615 | 763 | 908 | 1190 | 855 | 1059 | 1261 | 1653 |
16 | 541 | 672 | 800 | 1051 | 752 | 933 | 1111 | 1460 |
18 | 483 | 600 | 715 | 941 | 671 | 833 | 993 | 1307 |
20 | 436 | 542 | 647 | 852 | 606 | 753 | 898 | 1183 |
22 | 398 | 495 | 590 | 778 | 552 | 687 | 820 | 1081 |
24 | 365 | 455 | 543 | 716 | 508 | 631 | 754 | 995 |
26 | 338 | 421 | 502 | 664 | 469 | 584 | 698 | 922 |
28 | 314 | 391 | 468 | 618 | 437 | 543 | 649 | 858 |
30 | 294 | 366 | 437 | 578 | 408 | 508 | 607 | 803 |
Class IV
Densely Populated Areas
API Nominal Pipe Size (In.) | A-36 Steel Plate | A-572-Gr.50 Steel Plate | ||||||
1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | 1/4'' WALL | 5/16'' WALL | 3/8'' WALL | 1/2'' WALL | |
4 | 1405 | 1714 | 2009 | 2560 | 1951 | 2381 | 2791 | 3556 |
6 | 993 | 1220 | 1440 | 1858 | 1379 | 1695 | 2000 | 2581 |
8 | 778 | 960 | 1137 | 1477 | 1081 | 1333 | 1579 | 2051 |
10 | 633 | 783 | 929 | 1213 | 879 | 1087 | 1290 | 1684 |
12 | 538 | 667 | 793 | 1038 | 748 | 926 | 1101 | 1441 |
14 | 492 | 610 | 726 | 952 | 684 | 847 | 1008 | 1322 |
16 | 433 | 537 | 640 | 841 | 602 | 746 | 889 | 1168 |
18 | 387 | 480 | 572 | 753 | 537 | 667 | 795 | 1046 |
20 | 349 | 434 | 517 | 682 | 485 | 602 | 719 | 947 |
22 | 318 | 396 | 472 | 623 | 442 | 549 | 656 | 865 |
24 | 292 | 364 | 434 | 573 | 406 | 505 | 603 | 796 |
26 | 270 | 336 | 402 | 531 | 376 | 467 | 558 | 737 |
28 | 252 | 313 | 374 | 494 | 349 | 435 | 519 | 687 |
30 | 235 | 293 | 350 | 463 | 327 | 407 | 486 | 643 |
2. Project Cases :