Clean ORP Tester Oxidation-Reduction Potential Testing Meter

Price Negotiable Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 423 people viewed
Quantity
+-
 

Strider Instrument & Application Co. (Shanghai), Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
ORP30
Digital
Portable
Food Analysis, Medical Research, Biochemistry
CE
-1000 ~ +1000 Mv
1 Mv
±1 Mv
0 - 100.0 °c / 32 - 212 °f
CLEAN
L*W*H 210*100*65mm
(H× W× D) 185× 40× 48 mm
China
3122443543
Product Description
CLEAN ORP Tester
Easy ORP testing
ORP30 Tester is designed for easy Oxidation-Reduction Potential testing.
You can simply track mV value in the most convenient way.

Features

Waterproof, dustproof housing-IP67 rated.

Precise & easy operation, all functions operated in one hand.
Widest applications: meet your indoor and outdoor water measurement needs, from lab to field
hrow-out measurement.
User replaceable plane ORP electrode.
Large LCD with backlight.
1*1.5 AAA long battery life.
Self-Diagnostic for easy troubleshooting (e.g battery indicator, message codes).
Auto Lock Function
Floats on water

Specifications

Water analysis   Swimming pool   Waterworks  Surface water

Applications

 Range-1000 ~ +1000 mV
 Resolution1 mV
 Accuracy±1 mV
 Temp. Range0 - 100.0 °C / 32 - 212 °F
 Working Temperature0 - 60.0 °C / 32 - 140 °F
 Temp. Resolution0.1 °C / 1 °F
 Calibration Point1 points (Random point full-scale calibration)
 ElectrodeCS2930 platinum plane electrode
 LCD20* 30 mm multi-line crystal display
 LockAuto / Manual
 Auto backlight off1 minute
 Auto power off5 minutes without key be pressed
 Power1x1.5V AAA battery
 Dimensions(H×W×D) 185×40×48 mm
 Weight95g
 ProtectionIP67


Electrode use and maintenance
A good ORP electrode and its platinum sensing plateshould always be kept clean and bright, if the platinumplate of the electrode becomes rough or covered bypollutants after measurement, it should be cleaned withappropriate solution according to the nature of thepollutants. Please clean it as follows: (for referencel
Contaminants: detergents:Inorganic metal oxide (less than 1m dilute hydrochloricacidOrganic oil and grease thin detergent (weak alkali)Resin: high molecular substance (dilute alcohol,acetone, hexyi ether)Protein blood cell precipitate acidic enzyme solution(such as pepsin)Plgment substances (bleaching solution, hydrogenperoxide)
Inorganic pollution: immerse the electrode in 0.1M dilutehydrochloric acid for 15 minutes,gently wipe theplatinumn sheet of the electrode with a cotton swab, andthen clean it with tap water.Organic matter or oil pollution: immerse the electrode intap water with a small amount of detergent (e.g.detergent),and thoroughly clean the sensing surface ofthe electrode sensor Gently wipe the platinum sheet ofthe electrode with a cotton swab, and then rinse it withtap water. The cleaning is completed.If the platinum sheet of the electrode has formed anoxide film, please polish the sensing surface withtoothpaste or 1000 mesh fine sandpaper, and thenclean it with tap water (as shown on the right)The platinum sheet is connected with the glass. Pleasehandle it carefully when grinding.Service life of the electrode. It will vary depending on thefrequency of use. Generally, please replace the




Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA