CON3500
Except for Consumable Electrodes, The Body Is Guar
1 Years
LED
Food Analysis, Medical Research, Biochemistry
Non Portable
CE
Conductivity Meter
0.000us/Cm-400.0ms/Cm
0.001us/Cm-0.1ms/Cm
±0.5%F.S
K=0.01,0.1,1.0,10.0
Conductivity Range * Set The Conversion Coefficien
CLEAN
270*190*150
(H× W× D) 185× 40× 48 mm
China
3122443543
Product Description
CON3500 Conductivity / TDS / Salinity
It is suitable for accurate measurement of conductivity, salinity, total solid dissolution in harsh climate and complex industrial environment.![]() | ![]() | ![]() |
128 * 64 dot-matrix LCD display, switchable in Chinese and English, IP65 protection level, all-weather stable operation
Simple menu design, simple and convenient operation, graphical prompt, beautiful and clear interfaceSoftware digital filtering is adjustable, with enhanced hardware resistance to interference, making measurements more stable and adapted to complex industrial environments
Global access power supply 85~260VAC, but also customized DC model 18 to 36 VDC
RS-485 digital interface, MODBUS-RTU communication protocol, read and write two-way communication, can achieve remote complete control of the instrument
Three measurement modes CON (conductivity) SAL (salinity) or TDS (total dissolved solids)
Ultra pure water Industrial process Boiler water Circulating water
Conductivity | Range | 0.000uS/cm~400.0mS/cm |
Resolution | 0.001uS/cm~0.1mS/cm | |
Accuracy | ±0.5%F.S | |
Electrode constant | K=0.01,0.1,1.0,10.0 | |
Reference temp. | 15.0~35.0 °C | |
Temp. coefficient | 0.00~4.00% | |
Salinity | Range | Conductivity range * Set the conversion coefficient |
Resolution | 0.1g/L | |
Accuracy | ±0.5%F.S | |
TDS | Range | 0.000mg/L~200.0mg/L |
Total dissolved solids | Resolution | 0.001mg/L~0.1mg/L |
Accuracy | ±0.5%F.S | |
TDS factor | 0.40~1.00 | |
Temperature | Range | -10.0~130.0 ºC |
Resolution | 0.1 ºC | |
Accuracy | ±0.3 ºC | |
Temp. input | PT1000 | |
Temp. compensation | Automatic/Manual | |
Output type | wo 4~20 mA (Corresponding range can be set) | |
Transmission current | Accuracy | ±0.5 %FS |
Output load | Less than 500 Ω | |
Function relay | 1 (Can be set as cleaning or alarm function) | |
Relay control | Switch relay | 2 SPST relays |
Load capacity | 2.5A 230VAC | |
Transmission interface | 1 RS485 Isolation voltage 2500Vrms | |
Data transmission | Protocol | MODBUS-RTU (Read and write duplex communication) |
Power supply | 85~260VAC or 18~36VDC(User can order) | |
Operating temperature | 0~60°C | |
Working humidity | Relative humidity < 90% | |
Protection level | IP65 | |
Installation method | Dial installation | |
Dimensions | (H×W×D) 108×108×132 mm | |
Hole Size | 92.5×92.5 mm(Positive tolerance) |
Model | Specification | images |
CON3500 | Conductivity /Salinity /TDS Controller/Transmitter | |
CS3500 | Process Conductivity Sensor | |
CS3510 | Process Conductivity Sensor | |
CS3521 | Process Conductivity Sensor | |
CS3522 | Process Conductivity Sensor | |
CS3523 | Process Conductivity Sensor | |
Product Enquiry Form |