12kwh off Grid Lithium Battery Power Supply System for Outdoor/Household

Price Negotiable Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 254 people viewed
Quantity
+-
 

Shenzhen Gold Power Tech Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
GPESS-48250-302
off Grid
Government,Military/Security,Commercial,Home,Marin
Large Type
Goldpower
3.3kw 120V
12kwh
5
LFP
48V/DC
250ah
More Than 90%
Goldpower
Wooden Case Packing
Dimension: 610*602*1031(mm)
Shenzhen
8504401990
Product Description
1.1 Configuration
AC CHARGER,DC CHARGER,AC(OUT) INVERTER and FRONT PANEL
 

1.2 Working Principle
The system adopts AC charge and solar charge with MPPT. AC will complement the electricity when the solar energy is poor. The system is also with the function of bypass. AC will offer electricity first, but it will convert to inverter output if AC is off or it's over/under voltage, with 1-route 48V output and the max load is 5A.



 

1.3 Performance Index
Input
ItemMinTypicalMaxUnitNote
DC ChargerInput Voltage100 300Vdc 
Output Rated Voltage 48 Vdc
Output Current  30A
AC ChargerInput Voltage90220280Vac 
Input Rated Voltage 120 Vac
Input voltage frequency576063Hz
Power Factor 0.99  
Output Voltage 48 Vdc
Output Current  50A
 
Output
ItemMinTypicalMaxUnitNote
AC(OUT) InverterOutput voltage115120125Vac 
Output Rated Voltage 120 Vac
Output Voltage Frequency576063Hz
Output Current  30A
AC BypassOutput Rated Voltage90 164VacAC first
Output Voltage Frequency 60  
Output Current  30A
BAT+ BAT-(OUT)Output Voltage 48 VdcBAT output directly, with protection of short and current limit
Output Current 5 A
DC1+ DC2+ DC3+ GND(OUT)Output Voltage  300VdcThere's equipped with output interface and the user can connect a certain load to absorb the excess power when the PV input exceeds the max DC charging
 
Protection
ItemMinTypicalMaxUnitNote
Each ModuleOver TemperatureOutput is cut off when the inside temperature of heat sink is up to the peak point, then it will reduce 10ºC
Output Over CurrentAlso protection of over power and short
 
BMS
Battery ManagementDC Charger MPPT, charge with the max power
AC ChargerConstant current charge first, constant voltage charge later
Over/under Voltage ProtectionWith BMS itself
 
 
Insulation
ItemMinTypicalMaxUnitNote
Input-Cabinet 2121 VdcOnly test DC charge, AC charger and inverter
Input-Output 2121 Vdc
Output-Cabinet 750 Vdc
Isolated ResistanceAll the isolated resistance of input-output, input-earth and output-earth is no less than 10MΩ under the situation of normal atmosphere, 90% humidity and 500Vdc test voltage.
 
Environment
ItemMinTypicalMaxUnitNote
Working Temperature-10 40°C 
Extended Working Temperature-20 50°C 
Storage Temperature-10 60°C 
Humidity  90% 
Atmosphere70 106KPa 
Altitude0 3000m 
CoolingFan
Dust ProofRequirement of dust: diameter: >5um, density: ≤3×104pcs/m3, non-conductive, non-magnetic and non-caustic.  No protection of water proof