Opzv Series 2V 200ah Gel VRLA Battery for UPS Solar System

Price $1000.00 Compare
Min Order 24 Pieces
Shipping From Guangdong, China
Popularity 420 people viewed
Quantity
+-
 

Solid Power Industrial (Shenzhen) Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
OPG2-200
Lead-Acid Batteries
UPS, Lighting, Solar System
2V
Low Discharge Rate
Flat Battery
Acid
Fixed
Chargeable
ABS
ISO9001, ISO14001, CE
17.8kg
200ah
25 Years Design Life
3 Years
Sunstone Power
Carton+Pallet
103*206*356*389mm
Yunnan, China
85072000
Product Description

OPzV Series 2V 200ah Gel VRLA Battery for UPS Solar System
 
Product Specification
Nominal Voltage2V (1 cells)Operating Temp.RangeMaximum: -40~55°C (-40~131°F)
Nominal Capacity204AH (20hr, 1.80V/cell, 25°C/77°F)Recommended: -15~50°C (5~122°F)
200AH (10hr, 1.80V/cell, 25°C/77°F)Storage: -20~40°C (-4~104°F)
178AH (5hr, 1.75V/cell, 25°C/77°F)Nominal Operating Temp.Range25 ± 5°C
120AH (1hr, 1.60V/cell, 25°C/77°F)Cycle Use2.35~2.40V Temp.Coefficient -5mV/°C
DimensionLength 103 ± 2mmInitial Charging Current Less Than 50A
Width 206 ± 2mmStandby Use2.23V Temp.Coefficient -3mV/°C
Container Height 356 ± 2mmNo limit on Initial Charging Current
Total Height(with Terminal) 389 ± 2mmCapacity affected by
Temperature
40°C (104°F) 103%
Approx WeightApprox 17.8Kg25°C (77°F) 100%
TerminalM80°C (32°F) 86%
Container MaterialABSSelf DischargeOPG series batteries may be stored for up to 6 months max
Max. Discharge Current1000A (5S)At 25°C (77°F) and then a freshening charge is required internal internal
Internal ResistanceApprox 0.75mΩFor higher temperatures the time interval will be shorter
Features
Tubular plates
DIN standard
ABS case, Flame Retardent V0 is available
Gel technology
Stable quality and high reliability
25 years of design life (at 25°C)
Application :
Solar and Wind system
Alarm and security system
Telecommunication system
UPS
Emergency lighting
Auto control system
Electronic apparatus and equipment
DC power supply
24 hours online.
Detailed Photos

OPG Projects
Company Profile

Sunstone Power Group Headquarters: Solid Power Industrial (Shenzhen) Co., Ltd. Has 20 years of experience producing and selling battery products. Established in 2003, the company has grown into an enterprise group that consists of two factories in China: A lead-acid battery production factory in Yichun City, Jiangxi P. R, and a lithium battery production factory in Dongguan City, Guangdong P. R.; Two overseas companies are also established: Sunstone Power Industrial GmbH in Germany, and PT. Solid Power Energi in Indonesia.

Sunstone Power Group supplies high-quality batteries and other energy products to worldwide customers located in more than 100 countries. Furthermore, our German and Indonesian companies have their own office/warehouse which always keeps stocks to provide fast logistics and service to local clients. Moreover, In Germany, we also supply the whole solution for home use solar systems, camper van solar systems, etc. Besides our own overseas companies, we also built exclusive distributors in Malaysia, Yemen, Iraq, Mauritania, South Africa, Russia, Venezuela Honduras, and Costa Rica.


Partners



Certifications

Sunstone Power has been ISO9001 ,ISO14001 ,RISTI For OPG2-1000 ,SUNSTONE IEC61427-1:2013 ,approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't be near the hot source and don't under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol)

What do we support for worldwide partners?

A. With more than 20 years of specializing in producing sealed lead-acid batteries and car batteries.
B. With groups of professional engineers and salesmen.
C. High Quality with competitive price. We have our own plates factory where we can produce battery plates and also alloy. It gives us advantages in battery quality & cost control.
D. Our brand has gained market and good reputation which is easier for you to explore.
E. Good and comprehensive service.
F. Small MOQ for new clients so that you can test our quality before bulk order with less cost.
G. Different models have different warranty periods. During the period, you will enjoy free replacement if there is any problem.

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA