450/750V House Wiring Copper Halogen Free Polyolefine Insulated Electric Wire Cable HFIX
HFIX Wire Application
The conductor for the circuits of electrical equipment or instrumentation. Flame retardant and low toxic cross-linked polyefin cable which operates in maximum temperature 90°C.
HFIX Wire Voltage
450/750V
HFIX Wire Standard
KS C 3341: Flame retardant and low toxic cross-linked polyefin power cable and insulated wire
CONSTRUCTION
- Conductor : Annealed copper wire for electrical use (solid wire, circular copper wire, circular compressed copper wire)
- Insulator : Low-toxicity flame-resistant polyolefin
- Color of insulator : Black, white, red, green, yellow, blue
- Highest temperature : 90 ºC
HFIX Wire Technical Data
- Working voltage: 450/750
- Test voltage: 2500 volts
- Maximum operating temperature:90º C

Wire Structure:
Nominal Cross Sectional area (mm2) | Conductor | Thickness of insulation (mm) | Overall Diameter | Maximum continuous cuttent rating in free air (A) | Minumum insulation resistance at 70ºC (MΩ-km) | Cable weight (approx.) Kg/Km | Standard length (m) | ||
Number of wire (min) | Diameter Approx. (mm) | Lower Limit (mm) | Upper Limit (mm) | ||||||
1.5 | 1 | 1.38 | 0.7 | 2.6 | 3.2 | 21 | 0.011 | 22 | 100/C |
1.5 | 7 | 1.50 | 0.7 | 2.7 | 3.3 | 21 | 0.010 | 24 | 100/C |
2.5 | 1 | 1.78 | 0.8 | 3.2 | 3.9 | 29 | 0.010 | 32 | 100/C |
2.5 | 7 | 2.01 | 0.8 | 3.3 | 4.0 | 29 | 0.009 | 35 | 100/C |
4 | 1 | 2.25 | 0.8 | 3.6 | 4.4 | 37 | 0.0085 | 49 | 100/C |
4 | 7 | 2.55 | 0.8 | 3.8 | 4.6 | 37 | 0.0077 | 50 | 100/C |
6 | 1 | 2.76 | 0.8 | 4.1 | 5.0 | 48 | 0.0070 | 75 | 100/C |
6 | 7 | 3.12 | 0.8 | 4.3 | 5.2 | 48 | 0.0065 | 80 | 100/C |
10 | 1 | 3.57 | 1.0 | 5.3 | 6.4 | 67 | 0.0070 | 120 | 100/C |
10 | 7 | 4.05 | 1.0 | 5.6 | 6.7 | 67 | 0.0065 | 130 | 100/C |
16 | 7 | 5.10 | 1.0 | 6.4 | 7.8 | 92 | 0.0050 | 180 | 100/C |
25 | 7 | 6.42 | 1.2 | 8.1 | 9.7 | 127 | 0.0050 | 280 | 100/C |
35 | 19 | 4.59 | 1.2 | 9.0 | 10.9 | 157 | 0.0043 | 380 | 100/C |
50 | 19 | 8.90 | 1.4 | 10.6 | 12.8 | 191 | 0.0043 | 500 | 500/D |
70 | 19 | 10.7 | 1.4 | 12.1 | 14.6 | 244 | 0.0035 | 700 | 500/D |
95 | 19 | 12.6 | 1.6 | 14.1 | 17.1 | 297 | 0.0035 | 1000 | 500/D |
120 | 37 | 14.21 | 1.6 | 15.6 | 18.8 | 345 | 0.0032 | 1200 | 500/D |
150 | 37 | 15.75 | 1.8 | 17.3 | 20.9 | 397 | 0.0032 | 1500 | 500/D |
185 | 37 | 17.64 | 2 | 19.3 | 23.3 | 453 | 0.0032 | 1900 | 500/D |
240 | 61 | 20.25 | 2.2 | 22.0 | 26.6 | 535 | 0.0032 | 2500 | 500/D |
300 | 61 | 22.68 | 2.4 | 24.5 | 29.6 | 617 | 0.0030 | 3100 | 500/D |
400 | 61 | 25.65 | 2.6 | 27.5 | 33.2 | 741 | 0.0028 | 3900 | 500/D |
C: packing in coil. | |||||||||
D: packing in drum. |
PACKAGING:
A: Roll of 100 m
B: Reel of 1500 m.
C: Reel of 1000 m.
D: Reel of 500 m.
E: Multiple Reels of 1000 m.
Z - Length to the client's requirement.

Please contact us for technical support with the right cable selection for your power distribution projects and to discuss your maintenance or project specific requirements. We provide tailored solutions for this cable range which include storage, cutting to length, and 2 days collection as standard.


Any problem and inquiry pls contact with Tina